October 24, 2019 MEMORANDUM TO:
Scott W. Moore, Executive Director Advisory Committee on Reactor Safeguards FROM:
Anna H. Bradford, Director /RA/
Division of New and Renewed Licenses Office of Nuclear Reactor Regulation
SUBJECT:
NUSCALE POWER, LLC, DESIGN CERTIFICATION APPLICATION - SAFETY EVALUATION WITH NO OPEN ITEMS FOR CHAPTER 5, REACTOR COOLANT SYSTEM AND CONNECTING SYSTEMS By letter dated January 6, 20171, NuScale Power, LLC (NuScale), submitted its Design Certification Application to the U.S. Nuclear Regulatory Commission (NRC) for review, approval, and granting of design certification for the NuScale Standard Plant Design. NuScales letter is available in the Agencywide Documents Access and Management System (ADAMS) under Accession No. ML17013A229.
Based on our review of the application, the NRC staff is providing the Advisory Committee on Reactor Safeguards (ACRS) its Safety Evaluation (SE) with no open items for Chapter 5, Reactor Coolant System and Connecting Systems, (ADAMS Accession No. 19284A372). The SE is being provided to support a future meeting of the ACRS Subcommittee.
The NRC will withhold the SE from public disclosure to allow NuScale the opportunity to verify contents for proprietary, export control, or security related information. Therefore, the staff requests that the ACRS withhold the SE from public disclosure until the information has been released publicly in the ADAMS.
Docket No.52-048 CONTACT: Bruce Bavol, NRR/DNRL 301-415-6715 1 The Design Certification Application was submitted via a transmittal letter dated December 31, 2016.
- via email NRO-002 OFFICE DNRL/NRLB/PM DNRL/NRLB /LA*
DNRL/NRLB / BC DNRL/D NAME BBavol MMoore MDudek ABradford DATE 10/23/2019 10/21/2019 10/23/2019 10/24/2019