LER 79-032/01T-1 on 790626:insp of Seismic Class I Supports Revealed 92 W/Safety Factors of Less than 5,w/8 Having Safety Factors of Less than 1.Caused by Inadequate Design. All Mods Completed by 790719
ML19291B127
Person / Time
Site: Peach Bottom  Constellation icon.png
Issue date: 06/26/1979
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19291B126 List:
References
LER-79-032-01T, LER-79-32-1T, NUDOCS 7908290455
Download: ML19291B127 (1)


Text

~

LC FORAl Em6 *" U.~E NUCLEAR REGUL'A1084Y COMMisSIUN Tit Unit 2 LICENSEE EVENT REPORT Report No. 2-79-32/1T-1

  • UONTROL 8 LOCK: l l l l l (PLEASE PRINT OR TYPt! ALL REOulRED INPoRMATIONI i

4 9 lPlAlPIB lS l 2 l@l 010l lO UCENSE LICENSEE CODE to it IOlO!0lOl-l0101@l4l1l1]1l1l@l NUMSER 25 24 LICENS& TYPE 40 l

57 CAT bd l@

ON'T

' 1 4

$ URCs 60 L l@l015 St 1 DOCX01 ET-lNUMS 012 17 1768 }@l 0 lEVENT 4,9 6 I 2161719 le l@l018121017 7S REPORT CATE 980l@

ER QATE EVENT DESCRIPTION AND PROSA8LE CONSEQUENCES h 3 2 I In restonse to the analysis required by IE Bulletin 79-02, Rev.1,12h3 I w,j i seismic class I supports have been analyzed. Ninety two supports have i "TI Ii safety factors less +han five based on a design basis earthquake. Eight i EI of these have safety factors less than one; i.e., may fail during a de- t

) o I sian baeis earthcuake. Safety significance is mini ~.1, because calcula- l

) 7 l tions indicate sutports will withstand the operating basis earthquake. I O a l O&SR Co-4 ttee approved continued plant operation. I 8 9 80

  • CO
  • I:*E #CO'o*E SSCYO$E COMPONENT CODE SUS "3O

E S 3 38

) 9 8

LS la l@ La_]@ LA_l@ I Z l z l z i z i z i z l@19LZ 9 to 11 12 13 18 _

l@20Iz @

SE QUE NTI AL OCCURRENCE REPORT HEVISION LE RIRO EVENT Y EAR REPORT NO. CODE TYPE NO.

@ ,ajog 17191 l-l 23 1013I2l 24 l-1 10l1l lT I 30 L---J 32 11 21 22 28 77 28 29 38 N A N P NT METh HOURS 22 S 8 i POR 8. SU L MANUFAC RER l F l@[ F_j@

33 34 lZl@

3S y@

36 l0 IO l0 l0 l 37 40

[45 y l@ l42N l@ l43Z l@ lZI9l919l@

44 47 g

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS 27 i o i The cause of this occurrence was inadequate initial support design. I i6i l Seismically qualified pipe nodifications of all eight supports were i 2 I ccepleted on July 19, 1979 i ila l I i .t l l 8 g 80 ST 5  % POWER OTHER STATUS Ots RY DISCOVERY OESCRIPTION i 3 l El@ l110 l0 l@l U/3 at 100% l [Dl@l Work in IE Bulletin 79-02 l ACTIVITY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTivlTY LOCATION OF RELEASE i c- l N/A l l N/A l LZ_] @ l Z l@SES NUM9ER PEnso~~EL E POS TYPE DESCRIPTION i 7 l 0 l 0 l 0 l@[ Z_J@l N/f l

,E RSO~~E L iN;ULS

~UM8ER eESCRi, TION @

i l010101@l n/A I 8 9 11 12 80 . ,

LOSS 08 OH DAuAGE TO FACILITY .! ' '

oc"'"'o~

e 9 r;'igi yfi yoo82909ss i 10 80 DESCRIPTION

  • 2 o e 4

.SUEJ81 i_x_ n/A ///M#uv m V # "

i G8 69 i i iiiiiiiiiI:

80 ;

to g / ' [/ L/ /

NAME OF PREPARER V M.rJ. Cooney /

PHONE:

(215) 841-5020 g o