g
- nect,
'o,,
UNITED STATES
[
g NUCLEAR REGULATORY COMMISSION 3
E REGION I
,o'[
S 631 PARK AVENUE KING OF PRUSSIA, PENNSYLVANIA 19408 Docket No. 50-289 Metropolitan Edison Company ATTN:
Mr. R. C. Arnold Senior Vice President 100 Interpace Parkway Parsippany, New Jersey 07054 Gentlemen:
Enclosed is supplemental information to IE Bulletin No. 79-018.
This information is presented in the form of generic questions and answers which will assist you in responding to the actions required of IE Bulletin No. 79-018 issued on January 14, 1980. Should you have any questions regarding this supplemental information, please contact this office.
Sincerely, Ii& $.
.A /
e H. Grier 1 rector
Enclosures:
1.
Supplemental Information to IE Bulletin No. 79-018 w/ Attachments 2.
List of Recently Issued IE Bulletins CONTACT:
S. D. Ebneter (215-337-5296) cc w/encls:
J. G. Herbein, Vice President Nuclear Operations R. J. Toole, Manager, TMI-1 W. E. Potts, Radiological Controls Manager, TMI-1 J. J. Colitz, Plant Engineering Manager, TMI-1 L. W. Harding, Supervisor of Licensing E. G. Wallace, Licensing Manager I. R. Finfrock, Jr.
R. W. Conrad J. B. Lieberman, Esquire G. F. Trowbridge, Esquire Ms. Mary V. Southard, Chairperson, Citizens for a Safe Environment 8003140 MG
f ENCLOSURE 1 UNITED STATES SSINS No: 6820 NUCLEAR REGULATORY COMMISSION Accessions No:
OFFICE OF INSPECTION AND ENFORCEMENT 7912190696 WASHINGTON, D.C.
20555 IE Bulletin No.79-01B Supplemental Information Date:
February 29, 1980 Page 1 of 1 ENVIRONMENTAL QUALIFICATION OF CLASS IE EQUIPPENT Enclosed are the generic questions and answers which resulted from NRC Task Group / Licensee " workshop" meetings held recently in NRC Regional Offices regarding IE Bulletin No.79-01B.
This information is intended to further the understanding of the qualification review process and reporting requirements of the Bulletin.
The further intent of this information is to assist the licensees in providing a method of approach acceptable to the assigned NRC Task Review Group in determining adequacy of the environmental qualification of Class IE Electrical Equipment installed at their respective facilities.
It should be recognized that the review of the licensee's responses may generate additional need for guidance of finalized resolution of the environmental qualification issue.
Attachment:
Generic Questions and Answers to IE Bulletin No.79-01B DUPLICATE DOCUMENT Entire document previously entered into system under:
[