Text
,
bcc to DAC:ADM:
j ucy, CENTRAL FILES
[
UNITED STATES PDR:HQ I ?
s-7 %_
NUCLEAR REGULATORY COMMISSION LPDR 3,.,
, /
i REGION IV IIC
- 2, [j[
611 RYAN PLAZA DRIVE, SUITE 1000 MC 0,,
's,
February 29, 1980 Docket No.
50-265 Omaha Public Power District ATTN:
W. C. Jones, Division Manager -
Production Operations 1623 Harney Street Omaha, Nebraska 68102 Gentlemen:
Enclosed is Supplement Information to IE Bulletin No. 79-OlB.
This information is presented in the form of generic questions and answers which will assist you in responding to the actions required of IE Bulletin No.79-01B with regard to your power reactor facility (ies) with an operating license.
Should you have questions regarding this Supplement Information, please contact this office.
Sincerely, KarlV.hyfrit Director
Enclosures:
1.
IE Bulletin No.79-01B Supp,lement Information 2.
List of IE Bulletins Recently Issued cc:
S. C. Stevens, Manager Fort Calhoun Station Post Office Box 98 Fort Calhoun, Nebraska 68102 1
3\\5 4 0 03148,;g
SSINS No:
6820
^ "*** "
UNITED STATES 1106%
NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 February 29, 1980 IE Bulletin No.79-01B Supplement Information ENVIRONMENTAL QUALIFICATION OF CLASS IE EQUIPMENT Enclosed are the generic questions and answers which resulted from NRC Task Group / Licensee " workshop" meetings held recently in NRC Regional Offices regarding IE Bulletin No.79-01B.
This information is intended to further the understanding of the qualification review process and reporting requirements of the Bulletin.
The further intent of this information is to assist the licensees in providing a method of approach acceptable to the assigned NRC Task Review Group in determining adequacy of the environmental qualification of Class IE Electrical Equipment installed at their respective facilities.
It should be recognized that the review of the licensee's responses may generate additional need for guidance of finalized resolution of the environmental qualification issue.
Enclosure:
Generic Questions and Answers to IE Bulletin No.79-01B DUPLICATE DOCUMENT Entire document previously entered into system under:
ANO No. of pages:
[A