Forwards IE Bulletin 80-03, Loss of Charcoal from Std Type II,Two-Inch,Tray Adsorber Cells. Action Required
ML19290E524
Person / Time
Site: Fort Saint Vrain 
Issue date: 02/06/1980
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Millen C
PUBLIC SERVICE CO. OF COLORADO
References
NUDOCS 8003140159
Download: ML19290E524 (1)


Text

bec to DAC:ADM:

, p :8%,',

M ENTRAL FILES 4'

UNITED STATES POR:HQ Ei.,P) q. ~ i NUCLEAR REGULATORY COMMISSION LPOR i

REGION IV IIC

%, k g[

611 RYAN PLAZA oR;VE, SulTE 1000 NSIC 2,

g ARLINGTON. TE XAS 76o12

-: :tes February 6, 1980 Docket No. 50-267 Public Service Company of Colorado 1.TDI:

Mr. C. K. Millen Senior Vice President P. O. Box 840 Denver, Colorado 80201 Gentlenen:

Enclosed is IE Sulletin No. 80-03, which requires action by you with regard to 7our reactor facility with an operating ~.icense or a ecustruction parnit.

Should you have questions regarding this Sulletin or the acti:;.as required of you, please contact this office.

Sincerely, St. V. Seyfrit Director

Enclosures:

1.

II Bulletin No. 80-03 2.

List of Recently Issued II Bulleeins cc:

D. W. Warenbourg, Nuclear Production Manager Fort St. Vrain Nuclear Station P. O. Box 368

?latteville, Colorado 80651 L. Bray, Manager, Qualit7 Assurance 8003y40[

SSINS No.:

6820 UNITED STATES Accessions No.:

NUCLEAR REGULATORY COMMISSION 7912190669 T

0FFICE OF INSPECTION AND ENFORCEMENT 4

WASHINGTON, D.C.

20555 0

dy IE Bulletin No. 80-03 Date:

February 6, 1980 Page 1 of 2 LOSS OF CHARC0AL FROM STANDARD TYPE II, 2 INCH, TRAY ADSORBER CELLS Description of Circumstances:

During preliminary leak tests of charcoal adsorber cells in certain ventilation systems at Sequoyah Nuclear Plant, it was determined that on certain adsorber cells the spacing between rivets securing the perforated screen to the casing was too great to ensure adequate contact between the casing and the screen, thus allowing charcoal to escape.

The problem was discovered when a visual inspection detected loose charcoal on the floor of the filter housings and on the outside horizontal surfaces of the adsorber cells.

Loss of charcoal was also indicated by observation of light penetrating through the cells.

Add 4*ional inspection revealed that the rivets securing the perforated screens to the cell casing were approximately six inches apart and the screen appeared to be sagging away from the casing between rivets.

The particular adsorber cells being tested at Sequoyah Nuclear Plant were Flanders Type II pre-1974 fabrication.

There is a possibility that design of adsorber cells with wide spacing between screen rivers may pass initial freon leak tests but degrade significat.tly during operation thus reducing the margin of safety during postulated accidents.

The responses from this Bulletin will be used by the NRC to evaluate need for more frequent inspection / testing.

For all power reactor facilities with an Operating License:

1.

Determine if charcoal adsorber cells in use, or proposed for use, have the potential for a loss of charcoal incidental to handling, storage or use (as appropriate).

Particular attention should be directed to examina-tion of, a) rivet spacing resulting in separation of screen and cell housing, and b) adsorber cell or filter housing deformation causing loss of charcoal and/or channeling.

Either of these items could result in a degraded filtration system incapable of performing its i' tended function.

The preferred method of this determination is a visual :.ispection of the filter housing and adsorber cells as described in Secti on 5 of ANSI N510-1975.

If this method is not feasible, state in ' c.e report required by Paragraph 4 how the determination was made.

2.

For ESF filtration systems, any identified defective cells shall be replaced and the operability of the system (after cell replacement)

IE Bulletin No. 80-03 Date:

February 6, 1980 Page 2 of 2 demonstrated by leak testing within 7 days.

Preferred method of leak testing is as described in Regulatory Guide 1.52 and Section 12 of ANSI N510-1975.

3.

For normal ventilation exhaust filtration systems which employ charcoal adsorber cells and for which radioactive removal efficiency has been assumed in determining compliance with the "as low as reasonably achievable" design criteria of 10 CFR 50, Appendix I, any identified defective cells shall be replaced as soon as possible but at least within 30 days.

After replacement, the system should be demonstrated operable by leak testing within an additional 30 days.

Preferred method of testing is as described in Regulatory Guide 1.140 and Section 12 of ANSI N510-1975.

4.

Report in writing within 45 days of the date of this Bulletin the results of the determination required by Paragraph 1.

The report shall include the type of cells employed (manufacturer and cell design), system containing the cells, observed cell condition (degradation / sagging) and a discussion of visual inspection procedure and results.

For all Power Reactor Facilities with a Construction Permit:

1.

Visual inspection shall be conducted only if the charcoal adsorber cells have been purchased and shipment received.

A representative number (approximately 5) of each type of cell design /manuf,cturer s'=11 be visually inspected for such deficiencies as rivet spacing and screen / casing separation which could lead to loss of charcoal in;idental to handling, storage, or use.

2.

Report in writing within 45 days of the date of this Bulletin the results of the inspection required by Paragraph 1.

The repurt shall include the type of cells (manufacturer and cell design), observed cell condition (degradation / sagging) and a diccussion of the insi.ection procedure and results.

Reports shall be sent to the Director of the appropria:e NRC Regional Office listed in Appendix D of 10 CFR 20 with a copy to the D: rector, Division of Fuel Facility and Materials Safety Inspection, Office of Inspection and Enforcement, USNRC, Washington, D.C.

20555.

Approved by GAO, B180225(R0072); clearance expires, 7/ 31/80. Approval was given under a blanket clearance specifically for idennified generic problems.

IE Bulletin No. 80-03 February 6, 1980 RECENTLY ISSUED IE BULLETINS Bulletin Subject Date Issued Issued To No.

79-26 Boron Loss from BWR 11/29/79 All BWR Power Reactor Control Blades Facilities with an Operating License (OL) for action.

All BWR's with a Construction Permit (CP) for info rma tion.

79-27 Loss of Non-Class-1-E 11/30/79 All power reactor Instrumentation and facilities holding Control Power System Bus Operating Licenses (OLs)

During Operation and to those nearing licensing 79-23 Possible Malfunction of 12/7/79 All power reactor Namco Model EA 180 Limit facilities with an Switches at Elevated Operating License (OL)

Temperatures or a Construction Pe rmit (CP)79-01B Environmental Qualification 1/14/80 All power reactor of Class IE Equipment facilities with an Operating License (OL) 80-01 Operability of ADS Valve 1/11/80 All BWR power reactor Pneumatic Supply facilities with an Operating License (OL) 80-02 Inadequate Quality 1/21/80 All BWR licenses with Assurance for Nuclear a Construction Permit (CP) or Operating License (OL)

Enclosure