ML19290D819

From kanterella
Jump to navigation Jump to search
Generation Station Units 1, 2 and 3 - Registration of Dry Fuel Storage Canister
ML19290D819
Person / Time
Site: San Onofre, Holtec  
(DPR-013, NPF-010, NPF-015)
Issue date: 10/14/2019
From: Bates A
Southern California Edison Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards, Office of Nuclear Reactor Regulation
References
Download: ML19290D819 (2)


Text

SOUTHERN CALIFORNIA EDISON~

Al Bates Manager, Regulatory Affairs An EDISON INTERNAT!ONAL'M' Company October 14,2019 10 CFR 72.212 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Comr:nission Washington, DC 20555-0001

Subject:

Docket Nos. 50-206, 50-361, 50-362, 72-41/7Z- (bl/-lJ Registration of Dry Fuel Storage Canister San Onofre Nuclear Generation Station Units 1, 2 and 3

Dear Sir or Madam:

In accordance with the registration requirements given in 10 CFR § 72.212(b )(2),

Southern California Edison (SCE) hereby submits the following registration information for two canisters used for the storage of spent fuel at the Independent Spent Fuel Storage Installation of the San Onofre Nuclear Generating Station (SONGS).

Canister #1 Licensees' Name:

Licensee's Address:

Southern California Edison Company San Diego Gas & Electric Company City of Anaheim, California City of Riverside, California 5000 Pacific Coast Highway San Clemente, CA 92672 Reactor License Numbers:

DPR-13 (SONGS-1)

NPF-10 (SONGS-2)

NPF-15 (SONGS-3)

Docket Numbers:

50-206 {SONGS-1) 50-361 (SONGS-2) 50-362 (SONGS-3) 72-41 (SONGS ISFSI)

Contact Name and

Title:

Albert Bates, Manager, Regulatory Affairs JJ/J/ !!J 5 2 O

/Jµ/ 5 S Zip

J /c_ IL i /l)tv/ 5 S Cask Certificate No
Certificate of Compliance No. 1040, Amendment 2, January 9, 2017

Cask Model: HI-STORM UMAX Canister Storage System, MPC-37 Cask Identification Nos.: Multi-Purpose Canister (MPC) Serial No.: 092 Cavity Enclosure Container (CEC) Serial No.: 087 Canister# 2 Licensees' Name:

Southern California Edison Company San Diego Gas & Electric Company City of Anaheim, California City of Riverside, California Licensee's Address:

5000 Pacific Coast Highway San Clemente, CA 92672 Reactor License Numbers:

DPR-13 (SONGS-1)

NPF-10 (SONGS-2)

NPF-15 (SONGS-3)

Docket Numbers:

50-206 {SONGS-1) 50-361 (SONGS-2) 50-362 (SONGS-3)

. 72-41 (SONGS ISFSI)

Contact Name and

Title:

Albert Bates, Manager, Regulatory Affairs Cask Certificate No: Certificate of C~mpliance No. 1040, Amendment 2, January.9, 2017 Cask Model: HI-STORM UMAX Canister Storage System, MPC-37 Cask Identification Nos.: Multi-Purpose Canister (MPC) Serial No.: 074 Cavity Enclosure Container (CEC) Serial No.: 071 There are no commitments in this letter.

For additional information concerning the storage of spent fuel under this general license, please contact me at 949-368-6945.

a;;*[~

cc:

S. A. Morris, Regional Administrator, NRC Region IV M. V. Doell, NRC Project Manager, SONGS Units 1, 2 and 3 Z. Cruz, NRC Project Manager