e
- g UNITED STATES y
g NUCLEAR REGULATORY COMMISSION 7.
wAsmNoTCN. O. C. 20555 ss,*****/
NOV 161979 SSINS #6820 MEMORANDUM FOR:
D. G. Eisenhut, Acting Director Division of Operating Reactors, NRR FROM:
E. L. Jordan, Assistant Director for Technical Programs, Division of Reactor Operations Inspection, IE
SUBJECT:
EVALUATION OF QUALIFICATION TEST REPORTS FOR CLASS IE ELECTRICAL COMPONENTS The enclosed list of test reports on environmental qualification of class IE electrical components have been referenced by licensees of operating facilities in their responses to IE Bulletin 79-01.
Since it is our understanding that only a few of the test reports have been accepted by the NRC (identified in NUREG-0390 Vol. 3, No.1 dated July 15,1979),
we request that the acceptability of the test methods for the remaining reports be evaluated on an expedited basis.
We request that you identify an NRR contact for this effort and your planned schedule for evaluations.
In the evaluation please state the effect of the new guidelines and criteria upon tne previously ~ accepted ust; reports.
The IE inspections at the licensee's facilities are not expected to be affected by your schedule; however, the final evaluation will be.
The purpose of the site inspection is to verify that all of the components in the sampled system have been includsd in the licensee's review and that the physical installation of these components in the system has not compromised the environmental qualification of the component. The IE inspections are intended to concentrate on field verification of all components in a selected system or train of a safety system at a given facility.
If no significant discrepancies are identified in the sample at a specific facility, no further sampling will be required; however, if discrepancies are found, then additfonal inspection will be required on a case by case basis.
It is expected that the selection of inspection samole;will include different systems at similar facilities to provide the maximum opportunity for problem discovery.
I)-
. cwa
. Jordan, Assistant Director fo echnical Programs Division of Reactor Operations Inspectio_n CONTACT:
V. D. Thomas, TP 17oa 1
ii vu i
49-28180 a
IO B001220
D. G. Eisenhut 2
NOV 161979
Enclosure:
As stated cc:
N. C. Moseley, IE L4.'C. Lainas, NRR R. M. Satterfield, NRR S. H. Hanauer, NRR H. D. Thornburg, IE G. L. Madsen, RIV Task Group:
A. Finkel, RI R. Hardwick, RII J. Hughes, RIII D. Mcdonald, RIV J. Elin, RV 178815/
~
Franklin Institu,te Research I.ab (RIKL)
Test Raport Nos.
F-C2639 F-C3441 F-C2232-01 F-C4043-3 F-C3798 F-C2815 7-C2667 F-C2485-01 F-C2857 F-C4033-1 F-C3.6 83 F-C3721 F-C3117 F-C2935 F-C4927 F-C4350-5 F-C2750 F-C3271 F-c4539 F-( 3834 F-C3694 F-C4911-1 F-t3635 F-C2709 F-C3341 F-C5022-1 F-C5022-2 F-C3451 F-C2442-02 T-C2737 T-C2781 F-C2770 F-C4879-1 F-C4033-3 Besten Insulated Wire Ceccanv Test Recert Nos.
9298 (S111cen)
B910 75AD25 9299 (XIJ'E) 8021 75C008 3901 8807 8-21 5904 8921 3905 7843 Cenax Corocra:ico Tas: Race: t Nos.
IPS-27 IPS-78 IPS-137 IPS-29 IPS-325 IPS-348 I?s-30 IPS-16 IPS-327 IPS-73.2 IPS-383 IFS-329 IPS-73.4 IPS-107 IPS-112 Cenax Bulletin SA 1000 I?S-88 Yexhoro Co porati_on Tes: Reecrt Mos.
T3-1013 T4-6040 73-1068 NS-PLC-5023 (Ce:r.iss? m Letter No.)
T3-1097 ceters! Ilect-te Tas: Reoort Nos.
D**D GW p]"J[^" "
~\\
n dxD co 1788 15 L.
ca
74-50'2-3 EPAD-007 EPAD408 DAO-009 IPAO-046 EPAO-055 EPAO-056 ZPAO-057 EPA 0461 IXT-QTR-063 P01 - Electrical Panatration gg,j,g 97 r
General Electric Serviess Test Resort No.
100 Series Electric Penetration Joy Efer Test Emport Nos.
TA-4081 X-411 I-604 li=1:oreue Corporation Test Re ort Nov.
600456 600198 600451 (30003) 600426 (3-0009) 600376A 600168 Autocatic Switch Cocoa =y Test Re =rt Nos.
TP-2-0 6 8 AQS 21678/TR Barten Cual.ification Test Data 288 28SA 289 386 332 763 (Lot 1) & 764 (com=ission lettar No, NS-DfA-1950) 3411ev Ca:pa= r Test Re ert No.
3CCO QR 4:01-1152G7T Oketite Cococv Ecaineering Racorts 141 127 110E
.A1s[;3 1788153
=
o o LyL o
g
=
[2]
D. G. O'B_rie..
Test Report Nos.
C19QA051 c19QA053 Engineering Raport Nos.
ER192 EE272 TP-EV-101 Duke Power Tes: Raport No.
TR-0004-00 Rockbestos Ccucanv Test Reports Quallficatien of Firevall III, Clans 1E Electric cables (July 7. 1977)
Qualification of Tiravall III, Coaxial Construct. ions for Class II service in Nuclear Ce=erating Station.s (January 18, 1978)
Qualificatien of Firewall III, Class 1E Electric Cables (February 1,1977)
Report No. 13-10407-ECSS-13-2 Fincher & Forter Comome?
Test Reecrt 2204-51-3-006 Enstir.eering Recorts UP #2224-1, R?T #004 1
DP 12224-1, R?T #002 Isonedix Test Raeorts 375-02 1-2-775 1788 iSL.
Culf Electronic i
Sve ta-Recorts E-115-173 E-115-176 E-1.L5-180 E-115-LS1
[h f a-:n $ o Ng N$m A
]
e
Rosemount Test Reports 117415 Rev. A 117415 Rev. B 3788 97215A 127227 Rev. A 2767 Rev. B Similarity Report 67912A Combustier. Engineering Latten NS-CZ-1384 NS-CI-692 NS-CE-756 NS-CE-847 American Air Filter PEP-253 Inrite Cable Cemnanv Test Renort No.
75 IPCIA-27-P Iociceall Mfg. Cc=jr a_n2 Tast Resort No.
279 2-03-02 Rev. 1
~
Aute=stic Svitch Cc= cane Pcd me=o 126 62 Electro tatic Halief Valva AMD 18 millstona 1 PEP 42963 Tenval Qualifiestien Tese Daea 17000 Ravehe= Corporatien Test Resort Nos.
E317A D'.518 1010 EH513A RT 1508/l 7100 Rev.1 Rebartshaw Qualification Test Data 88481 Wyla Laboratorias Report Nos. 44114-1 and 44114-2 178815f-o ~ g n a ygAkt ce
~
m
Target Rock Company Test Raport No.
1500 Valcor Report Qualificatics test for 177' class 1E solenoid valve F/N V52600-515 Valva Type 1" viking Test Revert Nos.
OTP-118 OTP-119 OTP-120 OTP-124 NA".CC NAMCO report datad 3/3/78 vvie Laborato-des Test Reecre Nos.
43854-1 44107-1 43854-3 420S6-1 26304 44354-1 We s tir.:h e.:2= Tepteal 7.aports W Canada CWAPD-332 Y C.s:sda CWAPD-326 iiCAP-7744-L WCAP-9157 WCAP-74101 (Vol. I)
VCAP-7!.10-L (Vol II)
WCAP-7 709L VCAP-7520 WCAP-7829 VCAP-9003 WCAP-7929-L WCAP-3587 Rev. 1 WCAP-7153 WCAP-7343-L VCAP-7354-L WCAP-7301-L WCAP-7720 WCAP-6754 udAF-7?M WGA?137 Ba 6 co c 1= t u), /c.ox 7o w ea / Repercs Ba w- /o0 03 Ba w'- / o 0 92 - 2.
D""D'*D'TY l
ee3 AUA A e
E5]
1788 15 V Te