Forwards Fault Trees for Tcpb Safety Function.Also Forwards Sandia Labs Ltr Explaining Conditions Covered by Fault Trees.Requests Review & Advice on Revising Logic of Trees. W/O Encl
ML19290C415
Person / Time
Issue date: 07/02/1979
From: Angelo J
Office of Nuclear Reactor Regulation
To: Jerome Murphy
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
References
REF-GTECI-A-17, REF-GTECI-SY, TASK-A-17, TASK-OR NUDOCS 8001110379
Download: ML19290C415 (1)


Text

Distribution w/o enclosures I S. H. Hanauer-fl. Taylor O*!

/

11. Aycock H. Vesely f

J. A. Norberg F. Rowsome T. Scarbrough R. Budnitz p

D. Fischer J. Angelo H. George e

~

M. Srinivasan J. Zwolinski

[2 Generic Task No A-17 L. S ffer y, p y i9 a--

MEMORANDUM FOR:#J. Murphy, Probabilistic Analusis Staff RES FRON:

J. Angelo, Task Manager, Task A-17, Systems Interaction in Nuclear Power Plants A

SUBJECT:

EVALUATION OF FAULT TREES FOR TASK A-17 Enclosed are fault trees for the reactor coolant pressure boundary safety function which is one of the three safety functions that will be studied in Task A-17.

The other two functions that will be studied are decay heat removal and reactor subcriticality. Also enclosed is a letter from Sandia Laboratories which explains the operational conditions and occurrences that i

are covered by these fault trees.

5.3 series will be submitted to us by Sandia soon.Two additional fault trees in the Figu j

We request that you review these fault trees and give us advice or guidance I

on revising the logic of the trees as necessary. We plan to visit Sandia i

n=-

Laboratories on August 8-9, 1979 to discuss these particular fault trees, I

so we would appreciate receiving your comments before our departure on August 7, if possible.

You are, of course, invited to participate in the l

meeting at Sandia Laboratories.

J. Angelo

. Task Manager

Enclosures:

1.

Letter from Sandia Laboratories k.

dated July 13, 1979

'4 2.

Fault Trees (Figures 5.3 series) 5 1733 266 e

g

!n NW

........................f.

.o J

8001110.377

.