t

/

UNITED STATES 8

NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D. C. ?0555 g

\\...!../

JUN 2 61979 MEMORANDUM FOR:

A. J. Szukiewicz, Task Manager, A-24 FR0ft:

A. B. Bennett

SUBJECT:

A-24 TASK PLAN, PHASE 1 DRAFT #3 INTERIM POSITION Concurrence to the subject document is granted subject to the following comments:

1.

Para. l A-1, Category 1, second sentence, revise as follows:

Margins (see Section III B) should...used.

Reason: Cla rity.Section III B discusses method of adding margin.

2.

Para.1 A-2,1C3 (Category 1) add the word " complete" in the first sentence:

In lieu...the complete generic envelope shown... curves.

Reason: To clarify that the complete curve should be used for Category 1 applications.

3 1A-2 (Category II). Add parenthetical statement (IEEE 323-1971 portion of the curve)

Reason: To clarify usage of the referenced curve.

4 Para.1C, Category 1, revise the title as follows:

Temperature and Pressure for Main Steam Line Break (MSLB)

Conditions.

Reason:

To define "MSLB" sfg&w A. B. Bennett cc: