bcc to DAC:ADM:

0 UNITED STATES CENTRAL FILES

  1. g#"80 4'o, NUCLEAR REGULATORY COMMISSION PDR:HQ

'n REGloN IV LPOR

< l Il o

611 RY AN PLAZA DRIVE. SUITE 1000

%hM

.j ARLINGTON, TEXAS 76012 iib

%, N

/

NSIC November 26, 1979 Docket Nos.

50-313 50-368 Arkansas Power and Light Company ATTN:

Mr. William Cavanaugh III Vice President of Generation and Construction P. O. Box 551 Little Rock, Arkansas 72203 Gentlemen:

The enclosed IE Circular 79-23 is forwarded to you for your information.

No written response to this circular is required.

If you have any questions related to the subject, please contact this office.

Sincerely, Cg g

K. V. Seyfrit r

Director

Enclosures:

1.

IE Circular No. 79-23 2.

List of Plants That May Have Received Defective Starter or Contactors 3.

List of Recently Issued IE Circulars James P. O'Hanlon, Plant Manager cc:

1729 093 Arkansas Nuclear One P. O. Box 608 Russellville, Arkansas 72801 m

8001000017

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Circular No. 79-23 Date:

November 26, 1979 Page 1 of 1 79 /o E 50 4 %

MOTOR STARTERS AND CONTACTORS FAILED TO OPERATE Gould, Inc., Electrical Products Group, reported to the NRC on September 11, 1979 potential defects in certain NEMA Size 3, Starters and Contactors. A possible binding or seisure of the carrier assembly, within the support plate of the stationary contact assembly, is caused by an undersized dimension of the support legs.

Starters and contactors with date code 7822 to 7935, model and serial numbers A10, All, A12, A13, A14, A20, A21, A22, and P10 are involved.

Faulty units were manufactured and distributed between June 1, 1978 and August 30, 1979. The attached listing of nuclear plants, which have received some of this motor control equipment, represents a preliminary check of shipment records. This listing, however, may not be complete.

Gould, Inc., will recall uninstalled items for retrofit and has retrofit kits available for field installation.

Based on the above, licensees are advised to verify all motor starter and contactor shipments received from Gould, Inc., between June 1, 1978 and August 30, 1979, and assure that applicable model and serial number components are corrected by retrofit and subsequent electrical operation tests.

No written response to this Circular is required.

If you desire additional information regarding this matter, contact the Director of the appropriate NRC Regional Office.