VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION MONTHLY OPERATING REPORT MONTH Nov.
YEAR 1979 SUBMITTED:
Yvw D SUPER QTE) DENT - OPERATIONS E
APPROVED:
.NA,ER 1579 539 79121403 M
OPERATING DATA REPORT DOCKET NO.
50-338 DATE 12-6-79 COMPLETED BY W. R. Madison TELEPHONE 703 894-5151 0,PERATLNG STATUS
- 1. Unit Name:
Nnrth Anna Ifnit 1 Notes,
- 2. Reporting Period:
Noverbar 1979
- 3. Licensed Thennal Power (MWr):
2775
- 4. Nameplate Rating (Gross MWe):
947
- 5. Design Electrial Rating (Net MWe): 907
- 6. Maximum Dependable Capacity (Gross MWe):
92R 898
- 7. Slaximum Dependable Capacity (Net MWe):
S. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:
N/A
- 9. Power Level To Which Restrictal,If Any (Net MWe):
N/A
- 10. Reasons For Re.Metions,if Any:
N/A
'Ihis Month. _ __ Yr.-to-Date Cumulatise
- 11. Hours In Reporting Period 720 8.016 13.033
- 12. Nu.nber Of Hours Reactor Was Critical 0
5.478.4 10.525.Z__,
- 13. Reactor Reserve Shutdown Hours 0
51.5 148.3
- 14. Hours Generator On-Line 0
5,401.5 10.053.2
- 15. Unit Reserve Shutdown Hours 0
0 0
- 16. Gross Thennal Energy Generated (MWH) 0 21.083.118 26.279.913
- 17. Gross Electrical Energy Generated (MWH) 0 4.44si.776 8.146_149
- 18. Net Electrical Energy Genera:ed (MWH) 0 4,188,866 7,853,446
- 19. Unit Service Factor 0
67.4 77.1 0
67.4 77.1
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (Using MDC Net) 0 58.2 67.1 0
57.6 66.4
- 22. Unit Capacity Factor (Using DER Net)
- 23. Unit Forced Outage Rate 0
4.8 3.3
- 24. Shutdowns Scheduled Over Nett 6 Months (Type. Date.and Duration of Each):
N/A
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
December 22. 1979
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIA L CRITICA LITY INITIAL ELECTRICITY COMMERCIAL OPERATION
?000 00$Q 1519 540 mm
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.
50-338 UMT NA-1 DATE 12-6-79 COMPLETED BY W. R. Madison (703) 894-5151 TELEPHONE MONTH havamhpr 1979 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(,* Sve-Net) 1 0
37 0-0 2
33 o
0 0
3 39 4
0 0
20 0
5 0
21 0
0 6
22 0
7 D
0 8
24 0
0 9
25 0
0 10 0
26 0
0-l1 27 0
0 12 28 0
0 13 29 0
0 14 30 15 31 0
16 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
(9/77) 1579 341
DOCKET NO.
50-338 UNIT SilUTDOWNS AND POWER REDUCTIONS North Anna 1 UNIT N AME DATE 12-6-79 kl. H. Madison COMPLETED BY T
REPORT MONT11 November 1979 TEl-EPil0NE 703) 894-M 1 C
O n,
E No' Date g
f 5't "l,
Cause & Corrective
~
li en5cc n
3 Action to M
4 3y 3
55%
IWC"I
~?
gO Prevent Recurrence y di j Report #
wU o-2 g
6 2
Shutdown 79-13 Conti 1ued
- hru November, Durat on was 720 hour-I 3
4 F: Forced Reason:
Method:
Exhibit G -Instructions S: Scheduled A Equipment Failure (Explain) 1-Manual for Preparation of Data O
B Maintenance of Test 2 Manual Scram.
Entry Sheets for Licensee C-Refueling 3-Automatic Scram.
Event Reporn (LER) File (NURI:G-4-Olher (Explain) 0161)
D-Regulatory Restriction h
E Operator Training & Ucense Examination.
N F Administrative 5
G-Operational Error (Explain)
Exhibit I-Same Source (9/77)
Il-Other (Explain)