ML19290B113

From kanterella
Jump to navigation Jump to search
Discusses IE Insp of License 21-14810-01 on 791024 & Forwards Notice of Violation
ML19290B113
Person / Time
Issue date: 11/07/1979
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Le Donne T
MICHIGAN TESTING ENGINEERS, INC.
Shared Package
ML19290B114 List:
References
NUDOCS 7911300121
Download: ML19290B113 (2)


Text

-

f_- _2 mn ata

[G W

/

o, UNITED STATES E-7, NUCLEAR REGULATORY COMMISSION

~*

REGION lil

^

o, g

799 ROOSEVELT ROAD f

'g *

,o '

GLEN ELLYN ILLINols 6o137 NOV 7 1979 Michigan Testing Engineers, Inc.

License No. 21-14810 v1 ATTN:

Mr. T. S. Le Donne Corporate Safety Officer Suite 34 1000 Jorie Boulevard Oak Brook, IL 60521 Gentlemen:

This refers to the inspection conducted by Mr. R. L. Hague of this office on October 24, 1979, of activities at 24355 Capital Avenue, Detroit, MI authorized by NRC Byproduct Materials License No. 21-14810-01 and to the discussion of our findings with Mr. J. L. Cason at the conclusion of the inspection.

The inspection was an examination of activities conducted under your

. license : they relate to rediation safety ami to compliance with the Commission's rules and regulations and with the conditions of your license.

The inspection consisted of a selective examination of procedures and representative records, observations, independent measurements, and interviews with personnel.

During this inspection, certain of your activities appeared to be in noncompliance with 57C requirements, as described in the enclosed Ap-pendix A.

This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

Section 2.201 requires you to submit to this office within twenty days of your receipt of this notice a written statement or explanation in reply, including for each item of noncompliance: (1) corrective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.

The inspection also included a review of the actions described in your letter dated October 11, 1978 regarding the apparent items of noncompliance for License No. 21-14810-01 found during our August 22, 1978 inspection.

We have no further questions on these matters.

2118 348

/bf 7911300

t;a i 1973 Michigan Testing Engineers, Inc..

We will gladly discuss any questions you have concerning this inspection.

Jincerely,

//,' ) (O'

/W A. B. Davis, Chief Fuel Facility and Materials Safety 3 ranch

Enclosure:

Appendix A, Notice of Violation cc w/ encl:

Central Files Reproduction Unit NRC 20b PDR NSIC 2118 349 e