ML19290A469
| ML19290A469 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 08/30/1973 |
| From: | Jennifer Davis US ATOMIC ENERGY COMMISSION (AEC) |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| Shared Package | |
| ML19290A466 | List: |
| References | |
| CDR-158, NUDOCS 7911070644 | |
| Download: ML19290A469 (1) | |
Text
R0:I J.P.0'Reilly FS6EB ACTION CONTEOL FORM CDRdl58 A.
Action Code Metropolitan Edison Co. (Three Mile Island i Name of Licensee and Facility Docket No. or License No.
50-280 Title Electrical Conduit Seismic Hancer Deficiencies Origin Licensee Date Rec'd 8/28/73 B.
FS&EB Branch Coordinator:
Bryan Dreher X
Ellis Paulus Complet, ion Requested by C.
Action Requested of:
ADREv2 M&PP03 EPB RPB ADC0 03
. CB TAB OOE Region I
Date Requested 8/30/73 Completion Requested by Reference CDR dated 8/20/73 from above licensee.
D.
Action Requested I
In accordance with PI 0600/6, " Construction Deficiency Reporting," the Metropolitan Edison Company report of 8/20/73, cover Electrical Conduit Seismic Hanger Deficiencies, is being assigned to Region I for evaluation of technical adequacy of the corrective action being taken and final resolution of the deficiency.
E.
Date Action Cocpleted i
{
Close-out (Date & Method)
Cor=ents: If completion date is not consistent with your work schedule, please let us know.
1557 342
/
cLt,cQ,,C'MLdre J. G. Davis, Deputy Director for Field Operations t
Direc.: orate of Regulatory Operat_ons i
7911070 [9p