ML19289F876
| ML19289F876 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 05/09/1979 |
| From: | Galen Smith NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Bretthauer E ENVIRONMENTAL PROTECTION AGENCY |
| References | |
| NUDOCS 7906210005 | |
| Download: ML19289F876 (1) | |
Text
UNITED STATES fp are %
v NUCLEAR REGULATORY COMMISSION
+
- s) r? (
7 l,
E REGloN I
- [k']gy['g
-j 631 PARK AVENUE f+
KING O F PRU55! A. PE NNS Y LV ANI A 19406 e
%......o May 9, 1979 Mr. Erich Bretthauer Monitoring Operaticas Division EMSL/LV P.O. Box 15027 Las Vegas, Nevada 89114
Dear Mr. Bretthauer:
This is to ccnfir:: the results of the NRC neasurements of the EPA milk cross-check samples, as discussed by Dr. Montgercry of our staff with Mr. Lee Ziegler en May 3, 1979.
The NRC results are based on the 3.79 liters of milk received and are corrected to 2000 hr en April 28, 1979. The counting uncertainties are 1 sigma.
NRC NaI (TI) detector 21t 3 pC1/2 I-131 NRC Ge (Li) detector 221 2 pCi/4 I-131 Should you Fave any questions regarding this communicatica, please contact ce en FTS-590-3958, 3960.
Sincerely.
George H. Smith Senior Inspection and Enforcement Site Representative Three M2.le Island U.S. Nuclear Regulatory Cc==ission 790621000i 0
f L