05000338/LER-1979-066-03, /03L-0 on 790506:narrow Range Level Transmitter LT-496 in L Steam Generator Read Erratically.Channel Inoperable.Probable Cause Was Drain Lines Off Both High & Low Pressure Sides of Transmitter.Lines Capped

From kanterella
(Redirected from ML19289F543)
Jump to navigation Jump to search
/03L-0 on 790506:narrow Range Level Transmitter LT-496 in L Steam Generator Read Erratically.Channel Inoperable.Probable Cause Was Drain Lines Off Both High & Low Pressure Sides of Transmitter.Lines Capped
ML19289F543
Person / Time
Site: North Anna 
Issue date: 06/04/1979
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19289F541 List:
References
LER-79-066-03L, LER-79-66-3L, NUDOCS 7906110160
Download: ML19289F543 (2)


LER-1979-066, /03L-0 on 790506:narrow Range Level Transmitter LT-496 in L Steam Generator Read Erratically.Channel Inoperable.Probable Cause Was Drain Lines Off Both High & Low Pressure Sides of Transmitter.Lines Capped
Event date:
Report date:
3381979066R03 - NRC Website

text

flRC FORM 3o6 U S. NUCLE AR HEGULATORY COMMISSION (T77)

LICENSEE EVENT REPORT CONTROL BLOct [

l l

l l

l l@

(PLEASE PRIN T OR TYPE ALL REQUlHED INFORMATION) 1

(

lV A

fi l A l S 1 l@l 0 l 0 l - l 0 10 0

0 lo 0 10 @! 4 l l l l l ', >l l l@l l@

O i

Jti LIC U.5E I E Ju 57 CAI L3 l

8 9 LICENSLE COCE 14 L ice Ns E t.L*.13 H 23 CON'T sEYC[ l L ]@l 0 l 5 l 0 l 0 l0 l 3 l 3 l8 l@l 01 5l O l 61 7 9 l@lof6 ol4l7I9l@

o i

7 8

60 L1 DOC AE T Nyy.13sa G1 63 k VE'a T O A TE 14 15 HEPOH T DATE 80 EVENT DESCRIPTION AND PROBAOLE CONSEQUENCES l During normal flode 1 operation, indication from the narrc>w range level transmitter i

o 2

LT-496 for "C" steam generator was noted to be reading erratically.

This channel l

o 3

lwas declared inoperable and was placed in a tripped condition as per action statement l o

4

#4, Table 3.3-3, of T.S. 3.3.2-1.

The two remaining channels were functional; there-l o

s f

I ore, the health and safety of the general public was not affected.

This event is I

o 6

l reportable as per T.S. 6.9.1.9.b.

l o

7 o

H l

1 80 7

8 3 SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE CODE SU8 CODE COMPONENTCODE SU3 CODE SU8 CODE l H l B l@ [E.j@ [B_j @

VlAl LlVlE lX l @

l_EJ @ l_DJ @

O 9

7 8

9 10 11 12 13 la 13 20 SEQUENTI AL OCCUHRENCE HEPORT REVISION

__ EVENT YE AH HEPOH T h0.

CODE TYPE N O.

@ "LER ROI 71 o f l-In is is I W

IniaI l_.i.J 1-1 LOJ j=r

_ 21 22 23 28 26 21 28

?)

30 31 J2 AKEN ACT ON O PLA?T THO HOJH3 5d IT E F 4 US.

S PtIE MAN ACTURER LLJ@lfLJ@

LLJ@

LZJ@

l010101Ol l Y l@

((1J@

l f1 l@

lVll13l5l@

3J 34 33 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS lTha susopcted cause for the arratic i n rii ca t i nn fenm i T dQ6 Mas _aleak on the drain 1

o i

i llines off both tha high and low oressuro sidos of the transmitter Thesp linos worp I

l capped during a subseauent shutdown which did reduce the magnitude of the orablom.

I i

2 l

i i

4 l

l 7

8 9 80 STA

% PO.N E R CTwE 9 5TATUS ISCOV RY DISCOVERY DESCRIPTION

[_E_J @ 11 10 10 l @ l N/A l

lBl@l Operator Observation l

i s

ACTIVITY C. TENT RELEASEO 03AELEASE AMCLNT OF ACTIVITY LOCATION OF RELEASE N/A l

l l

i 6

1 9 9 19 11 44 45 80 PEB W st i s1

, a - -i q

- 2T CN h

' uM, ea

- n 1010 0l@lzl@l ft/A l

i i

pee m N A',N &

" o ms - O.

2230 348 lilal101Ol01@l fuA I

1 8 9 11 12 60 LOS3 OF OH DAMAGE TO FACitiTV TYPE D E SC RIP TI ON

[_Z_j@l ft/A i 9 7

8 9 10 BJ PU AltCI TY NHC USE ONLY m900110Lo l l l l :;

I;;"Nj@ DESCRIPTION co L

l ft/A l

ll l

ll 2

O 7

8 9 10 68 63 80 7, W. R. Cartwright M-N-M M

{,

enONE.

NAce05gacPanta

Virginia Electric and Power Company North Anna Power Station, Unit No.1 Attachment: Page 1 of 1 Docket No:

50-338 Report No.: 79-066/03L-0

Description of Event

During Mode 1 operation after an extended outage, the level indicator for level transmitter LT-496 was noted to be reading erratically.

The effecteo channel was placed in a tripped condition as per action statement #4 of table

3. 3-3 o f T.S. 3. 3. 2.1.

Probable Consequenca of Occurrence The engineered safety feature actuation system required by T.S. 3.3.2.1 is provided to initiate automatic protective actions in the event of an accident.

In this case, the steam generator level channels are used to initiate the actions described by table 3.3-3 sections 5 and 6 of T.S. 3.3.2.1.

Placing the affected channel in a tripped condition changes the protective action coincidence from the normal 2 out of 3 to a more conservative 1 out of 2.

The health and safety of the general public is not affected. There are no generic implications.

Cause

The cause for the erratic indication from LT-496 was steam leaks on both the high and low pressure side drain lines on the transmitter.

Immediate Corrective Actions

Placed the associated level channel in a tripped condition as per action statement #4 of T.S. 3.3.2.1.

Scheduled Corrective Action Capped the two suspected drain lines during a subsequent shutdown. This did reduce the magnitude of the oscillation.

Returned LT-496 to service.

Action Taken To Prevent Recurrence The exact cause of the oscillation is still under investigation.

2230 549