ML19289D835

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 70-1308/78-07 on 781204-06 & 11-12.No Noncompliance Noted
ML19289D835
Person / Time
Site: 07001308
Issue date: 01/14/1979
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Zahn L
GENERAL ELECTRIC CO.
Shared Package
ML19289D836 List:
References
NUDOCS 7903190047
Download: ML19289D835 (2)


Text

-

,g*

4, UNIT E D STATES

  • [,

NUCLE AR REGULATORY COMMISSION 4

j

{

REGlo?: fil

  • 3 '

"?"'

e f 799 ROCSE V E LT AO AD

% M T'/ /

< w, w.,., iu g.c.;

's,

....+

J4ni 1 JI-Docket No.70-139 General F1.ectric Company ATTN:

Mr. L. L. Zahn, Jr.

Manager, Spent Fuel Services Operation 175 Curtner Avenue San Jose, CA 95125 Gentlemen:

This refers to the inspection conducted by Messrs. L. R. Greger and C. C. Peck of this office on December 4-6 and 11-12, 1978, of activ-ities at Morris Operation authorized by NRC Special Nuclear Material License No. SNM-1265 and to the discussion of our findings with Mr. E. E. Voiland and members of his staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during the inspection. b*ithin these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and interviews with personnel.

No items of noncompliance with NRC requirements were identified during the course of this inspection.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room, except as follows.

If this report contains information that you or your contractors believe to be proprietary, you must appiy in writing to this office, within twenty days of your receipt of this letter, te withhold such information from public disclosure. The application must include a full statement of the reasons for which the information is considered proprietary, and should be prepared so that proprietary information identified in the application is contained in an enclosure to the application.

79031900'(7

J.

~'

General Electric Company We will gladly discuss any questions you have concerning this in..iec t ion.

Sincerely, V

A. B. Davis, Chief Fuel Facility and Materials Safety Branch

Enclosure:

IE Inspection Rpt No. 70-1308/78-07 cc w/ encl:

Mr. E. E. Voiland, Manager Morris Operation Mr. D. M. Dawson,>bnager Licensing and Transportation Fuel Recovery Operations Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC' Mt. Dean Hansell, Office of Assistant Attorney General

~