I I

a F.Y 4P l

Batielle Columbus Laboratories l

I i

Report I

.t D

I z.

.. js e

..~

'v

+-

... r.

I r.

+

y l

+ '

,[. 7 3

x,

~

(

g

  • g

+

w ll L x L l*;- l 1 -L A l

William F. Clapp Laboratories,Inc.

g Duxbury, Massachusetts I

i I

I g

2s0129 s

PROGRESS REPORT FOR Tile FOURTEENTH QUARTER on I

1 WOODBORER STUDY ASSOCIATED WITII Tile OYSTER CREEK GENERATING STATION I

to JERSEY CENTRAL POWER 6 LIGl:T COMPANY December 15, 1978

~

by B.R. Richards, C.I. Belmore, and R.E. Ilillman Report No. 14876 August 11 to November 10, 1978 BATTELLE I

Columbus Laboratories William F. Clapp Laboratories Duxbury, Massachusetts 02332 Battelle is not engaged in rescarch for advertioing, calco promotion, or publicity purpouco, and this report majr not be reproduced in full or in part for cuch purpocco.

TABLE OF CONTENTS Page INT RODUCT ION.....................................................

1 PROCEDURES AND INTERIM DATA......................................

1 Exposure Panels.............................................

1 Water Quality..............................................

11 Teredinid Gonadal Development Studies.......................

11 I

LIST OF TABLES Table 1.

Geographical Locations of William F. Clapp E

Laboratories' Exposure 1anel Arrays Submerged June, 1975, Barnegat Bay, New Jersey..................

3 Table 2.

Summary Data for Incidence of Teredinidae in Panels Removed September 6-7, 1978....................

6 I

Table 3.

Summary Data for Incidence of Teredinidae in Panels Removed October 2-3, 1978......................

7 Tabic 4.

Summary Data for Incidence of Teredinidae in Panels Removed November 8-9, 1978.....................

9 Table 5.

Summary Data of Incidence of Limnoda bMpunchaba in Panels Removed September, October, and

November, 1978.......................................

10 I

Tabic 6.

Water Quality at Exposure Panel Stations, September, 1978......................................

12 Table 7.

Water Quality at Exposure Panel Stations, I

October, 1978........................................

13 Table 8.

Water Quality at Exposure Panel Stations, I

November, 1978.......................................

14 Tabic 9.

Condition of Gonads of Teredinid Borers Removed From Exposure Panels in Barnegat Bay from September through November, 1978.....................

15

I I

TABLE OF CONTENTS LIST OF FIGURES Page Figure 1.

Outline of Barnegat Bay Showing Geographical Locations of Exposure Pane 1s..........................

2 I

I I

~

I O

I

1 I

WOODBORER STUD 1 ASSOCIATED WITil TIIE OYSTER CREEK GENERATING STATION by B.R. Richards, C.I. Belmore, and R.E. Ilillman INTRODUCTION The William F. Clapp Laboratories of Battelle's Columbus Laboratories is conducting an investigation to determine whether the generating station is affecting the resident marine borer population I

in Oyster Creek to the extent that that population is contributing significantly to marine borer-caused damage in Barnegat Bay.

A description of the program and procedures used may be found in the First Quarterly Report on Woodborer Study Associated with 1;

the Oyster Creek Generating Station, Report No. 14647, dated October 31, 1975, with the exception that the marine borer larvae program was discontinued in November, 1977.

This report presents the summary data for the fourteenth quarterly period from August 11 through November 10, 1978.

Exposure Panels The long-term and short-term exposure panels were retrieved and replaced with new untreated pre-soaked (for two weeks) panels at the 20 exposure sites in Barnegat Bay and adjacent waters (Figure 1) during the weeks of September 5-8, October 2-4, and November 7-10.

1978.

Long-term and short-term panels at all stations were retrieved I

and replaced.

Table 1 describes the geographical locations of the exposure I

sites. The summary data for the laboratory examination of the panels may be found in Tables 2 through 5.

I

I MANASQUAN INLET 4

/

ERIELLE POINT I

INTRACOASTAL s

WATERWAY CANAL HANTOLOKING I

KET LE CREEK I

t I

O I

SEASIDE ATLMiTIC OCEAN f

SLOOP CREEK HOLLY PARK N I

atL6 c

I STOUTS CREEK SEDGE I

1B II ISL D i

10A s

10,

O j$

p OYSTER

'~

I REEK BARNEGAT INLET OYSTER CREEK 6

3 7

e NUCLEAR GENERATING STATION WARETOWN I

CITY BARNEGAT BEACH AE MW CONKLIN h

i ISLAND I

O

}

2

} HILES a

BARNECAT INLET, NEW JERSEY g

I Latitude 39* 45.8 N S

i Longitude 74* 06.0 W

[

E 2-W A4 FIGURE 1.

OUTLINE OF BARNECAT BAY SHOWING CEOGRAPHICAL LOCATIONS OF EXPOSURE PANELS

M M

M M

M M

M M

M M

M M

M M

M M

M TABLE 1.

GEOGRAPHICAL LOCATIONS OF WILLIAM F. CLAPP LABORATORIES' EXPOSURE PANEL ARRAYS SUBMERGED JUNE, 1975, BARNEGAT BAY, NEW JERSEY Structure to be used for Nearest Previous Approximate Latitude Site No.

Site Suspension of Rack Data Stations and Longitude 1.

Barnegat Coast Guard Finger Pier WC 1 Lat. 39* 45.8'N Station, Earnegat Inlet WFCL 1948-1967 Long. 74 06.5'W 2.

Ashton Marina Bulkhead WC 13,14 Lat. 39" 40'N 1450 Bay Ave.

Long. 74* 13'W Manahawkin 3.

Iggte's Marina Bulkhead WC 16,17,18,19 Lat, 39* 45'N East Bay Ave.

Long. 74* 12.5'W Barnegat (Conklin Island) 4.

Liberty Harbor Marina Bulkhead WC 21 Lat. 39' 47'N Washington Ave.

R. Turner Long. 74* 11'W Warctown Rutgers U.

u 4-A*.

Holiday Harbor Marina Bulkhead WC 21 Lat, 39* 481N Lighthouse Drive R. Turner Long. 74* 11'N Waretown Rutgers U.

5.

Mouth of Oyster Creek, Dock WC 29,30 Lat, 39' 48,5'N Lot.4, Compass Road Rutgers U.

Long. 74* 10.3'W Offshore.End 6.

Oyster Creek #1 Dock Lat. 39* 48.5'N Lagoon, Inshore End Leng. 74* 10.35'W 37 Capote.n Drive 7.

Private Dock End of Dock WC 27,28 Lat, 39* 48.5'N Dock Ave.

R. Turner Long. 74* 11.l'W- - ~

Oyster Creek Rutgers U.

Sands Pt. Harbor Waretown en

M M

M R

M M

M M

M M

M M

M M

M TABLE 1.

(continued)

Structure to be used for Nearest Previous Approximate Latitude Site No.

Site Suspension of Rack Data Stations and Longf*.ude Cross Member WC 26 Lat. 39* 48.7'N 8.

Oyster Creek-R.R.

Bridge Bridge Rutgers U.

Long. 74* 12'W Discharge Canal 9.

Forked River Cross Member WC 31 Lat 39* 49.2'N South.iranch a.R.

Eridge Rutgers U.

Long. 74* 12.2'W Intake Canal 10.

Teds Marina Pier WC 33,34 Lat. 39" 50.l'N Bay Ave.

Long. 74* 11.6'W Forked River 10A*.

Private Dock Under Dock Lat. 39* 49'N 1-16 Aquarius Ct.

Long. 74* 10'W Forked River 10B*.

Private Dock Under Dock Lat. 39* 49.4'N 1307 Beach Blvd.

Long. 74* 10.1'W Forked River

~11.

Forked River Bulkhead WC 35 Lat. 39* 49.7'N (near mouth)

Rutgers U.

Long. 74* 10'W 1413 River View Drive 12.

Ste m Creek Bulkhead WC 38,40,41 Lat 39* 50.5'N 1273 Capstan Drive R. Turner Long. 74* 08.8'W Wurtz Rutgers U.

13.

Roclnak's Yacht Basin End of Pier WC 46 Lat. 39* 52'N Seasiew Ave.

Long. 74* 09'W Lanoka Harbor Cedar Creek

M M

M M

M M

M M

M M

M M

M M

M TABLE 1.

(continued)

Structure to be used for Nearest Previous Approximate Latitude Site No.

Site Suspension of Rack Data Stations and Longitude 14.

Dicks Landing Pier WC 49 Lat. 39' 54'W Island Drive R. Turner Long. 74* 08.l'W Bayville (Holly Park)

Nelson 15.

Winter Yacht Basin Inc.

Pier WC 57 Lat. 40' 02.5'N Rt. 528 Long. 74* 03.5'W Mantoloking Bridge W. Mantoloking 16.

Berkely Yacht Basin Pier WC 60,61 Lat. 39 55.9'N J. Street Long. 74* 04.9'W Scaedde 17.

Island Beach Pier WC 68 Lat. 39" 47.l'N ui State Park Long. 74* 05.9'W (Sedge Island)

All exposure panel racks suspended in a minimum water depth at mean low water of at least three feet. Racks hung with nylon line from existing structures so the bottom panels are close to, but not touching the bottom. Racks at Forked River railroad bridge and Oyster Creek railroad bridge suspended with wire rope.

WC = Woodward-Clyde WFCL = William F. Clapp Laboratories

  • Site 4-A installed April, 1977 Sites 10 A, 10 B installed April, 1978.

m M

M M

M M

M M

M M

M M

m TABLE 2.

SOSIARY DATA FOR INCIDENCE OF TEREDINIDAE IN PANELS REMOVED SEPTEMBER 6-7, 1978 No. of Size Range Site Panel Specimens Percent Filled in mm.

Species Identification Remarks 1

P 130 25

<l-80 T. navaZis Larvae present C

330 5

<l-14 2

P 1

<1 13 Terado spp.

C 1

<1 4

Teredo spp.

4 P

1 1

65 B. gouZdi C

0 5

P 12]

20

<l-100 91 T. bartschi Umbonate larvae present C

18

<1

<l-10 1 T. bartschi 6

P 1

<1 2

C 2

<1

<1 7

P 567 98

' 150 1 B. gouldi, Umbonate larvae present 536 T. bartachi C

1104 10

<l-10 4 T. bartschi, c'

150 Teredo spp.

10A P*

2 8

100-170 B. gouZdi 1 with ripe gonads C

0 11 P

14 22 17-145 B. gouZdi C

0 13 P

7 12 26-88 B. gouldi C

4

<1

<1-3 1 Bankia spp.

14 P

9 17 45-120 B. goulds C

7 1

<l-27 B. gouldi 17 P

1

<1 24 T. navalis C

0 Sites 3, 4A, 8-10, 10, 12, 12, 15, 16, no Teredinidae present.

P = Long-term panel, submerged March, 1978 - unless otherwise noted.

C = Short-term panel, submerged August, 1978.

  • = Submerged 5 months.

M M

M M

M M

M M

M M

M M

TABLE 3.

SUMMARY

DATA FOR INCIDENCE OF TEREDINIDAE IN PANELS REMOVED OCTOBER 2-3, 1978 No. of Size Range Site Panel SpecimensI Percent Filled in mm.

Species Identitication Remarks 1

P 364 80

<1-100 T. navalis C

31

<1

<1 2

P 3

15 70-185 T.

._.zZis C

0 4

P 4

7 30-100 B. gouldi C

0 4A P

1 1

37 B. gouZdi C-0 5

P 171 25

<l-160 1 B. gouldi, Umbonate larvae present.

90 T. bartschi C

53

<1

<1-1 6

P 15 1

<l-57 1 T. bartschi Umbonate larvae present C

11

<1

<l-1 7

P 360 99

<l-80 T. bartschi C

21

<1

<1-3 10A P

5 25 140-200 B. gouldi C

0 10B P

2 12 185-260 B. gouldi C

0 11 P

33 50

<l-140

'O B. gouldi, 1 T. navalis C

0 12 P

2 5

80-110 B. gouldi C

0 13 P

6 14 16-150 B. goulds C

0 14 P

9 25 75-165 B. gouldi C

0

m M

M M

M M

M M

M M

M M

M TABLE 3.

Continued No. of Size Range Site Panel SpecimensI Percent Filled in mm.

Species Identification Remarks 15 P

1 2

95 B. gouZds C

0 17 P

2

<1

<l-1 C

0 Sites 3, 8-10, 16 - no Teredinidae present.

P = Long-term panel, submerged April, 1978.

C = Short-term panel, submerged September, 1978.

co a

m m

M M

M M

M M

TABLE 4.

SUMMARY

DATA FOR INCIDENCE OF TEREDINIDAE IN PANELS REMOVED NOVEMBER 8-9, 1978 No. of Size Range Site Panel SpecimensY Percent Filled in mm.

Species Identification Rc,nrks 1

P 430 98

<1-150 T. navalis C

650 1

<1-1 2

P 5

17 63-175 T. navalis 1 with ripe gonads C

0 4

P 1

4 155 B. gouldi C

0 5

P 680 50

<1-220 1 B. gouldi, Larvae present 79 T bartcchi C

0 6

P 58 15

<1-52 22 T. bartechi Umbonate larvae present C

0 7

P 24C0 99

<1-115 2 B. gouldi, Several releasing larvae 300t T. bartachi e

C 0

8 P

1 13 450 B. goulds C

0 10A P

3 15 130-245

3. gouldi C

0 11 P

12 45 11-200 10 B. gouldi, 2 T. navalis C

0 13 P

8 45 120-250 B. gouldi C

0 14 P

13 70 115-255 B. gouldi C

0 17 P

5 15 60-180 1 B. gouldi, 4 T. navalic C

0 Sites 3, 4A, 9-10, 10B, 12, 15 no Teredinidae present.

P = Long-term panel, submerged May, 1978.

C = Short-term panel, submerged October, 1978.

10 TABLE 5.

SUMMARY

DATA FOR INCIDENCE OF Limnoria tripuncbaba IN PANELS REMOVED SEPTEMBER, OCTOBER, AND NO "MBER, 1978 I

September October November No. of No. of No. of No. of No. of No. of Site Panel Tunnels Specimens Tunnels Specimens Tunnels Specimens 1

P 245 280 260 300 97 81 C

1 1

0 0

0 0

2 P

950 1100 1000 1300 900 950 C

9 10 0

0 0

0 3

P 14 12 0

0 0

0 C

0 0

0 0

0 0

4 P

515 300 475 350 360 410 C

0 0

0 0

0 0

4A P

1800 2000 1250 1500 900 800 C

1 2

0 0

0 0

Sites 5-17, no Lirmoria present.

Gravid females and juveniles present at all locations.

I

~

I

11 Water Quality Salinity, water temperature, dissolved oxygen, and pil were determined with a Hydrolab (Model II B).

The results for September, October, and November may be found in Tables 6 through 8.

Teredinid Gonadal Development Studies Table 9 shows the gonad condition of the teredinid borers collected from September through Movember, 1978.

Included are results from special long-term panels exposed for a 12-month period.

12 TABLE 6.

WATER QUALITY AT EXPOSURE PANEL STATIONS, SEPTEMBER,1978 Depth Station Date Time in Feet Salinity - o/oo Temp. *C 02 PH 1

9/7/78 0930 6.0 21.0 23.3 8.4 7.8 2

9/7/78 0955 2.0 19.0 24.0 7.3 7.5 3

9/7/78 1025 3.0 19.9 23.7 6.8 7.7 l

4 9/7/78 1040 3.0 20.4 24.0 5.0 7.4 4A 9/7/78 1055 3.0 19.5 24.5 5.4 7.5 5

9/7/78 1110 4.0 15.8 27.0 6.8 7.7 6

9/7/78 1120 4.0 15.8 25.8 7.7 7.6 7

9/7/78 1128 3.0 17.0 27.4 6.5 7.3 8

9/7/78 1151 6.0 15.8 26.0 6.2 7.4 9

9/7/78 1204 6.0 17.0 24.0 6.7 7.7 10 9/7/78 1403 3.0 11.8 25.0 7.0 7.2 10A 9/7/78 1237 3.0 17.0 24.0 7.4 7.8 10B 9/7/78 1250 3.0 17.0 24.5 8.1 7.7 11 9/7/78 1303 4.0 17.2 24.5 7.8 7.8 12 9/7/78 1427 3.0 17.2 24.5 6.5 7.7 13 9/7/78 1453 3.0 19.2 24.0 7.4 7.2 14 9/7/78 1523 3.0 13.1 25.0 8.4 7.9 15 9/7/78 1621 3.0 13.8 24.5 8.4 8.1 16 9/6/78 1600 4.0 14.6 24.3 8.3 8.2 17 9/6/78 1645 2.0 27.4 22.6 8.2 8.8 I

I

13 TABLE 7.

WATER QUALITY AT EXPOSURE PANEL STATIONS, OCTOBER, 1978 Depth Station Date Time in Feet Salinity - o/oo Temp.

  • C 02 Pli 1

10/3/78 0915 6.0 29.9 18.2 8.7 8.1 2

10/3/78 0950 2.0 23.3 17.7 8.1 8.4 3

10/3/78 1030 3.0 22.7 18.1 8.1 8.4 4

10/3/78 1047

3. 5 22.7 17.8 7.8 8.5 4A 10/3/78 1100 3.5 22.7 18.3 8.4 8.7 5

10/3/78 1115 4.0 17.9 19.0 8.7 8.7 6

10/3/78 1130 4.0 17.7 18.7 9.5 8.7 7

10/3/78 1140 3.0 17.9 17.3 8.8 8.6 8

10/3/78 1155 6.0 19.2 17.5 8.8 8.7 9

10/3/78 1206 6.0 19.9 18.0 9.2 8.8 10 10/3/78 1411 3.0 19.9 19.0 7.7 9.1 10A 10/3/78 1320 3.5 20.6 18.5 9.4 9.1 10B 10/3/78 1343 3.5 22.7 19.0 8.9 9.1 11 10/3/78 1350 4.0 18.5 18.5 8.0 9.3 12 10/3/78 1423 3.5 17.2 20.0 8.4 9.2 13 10/3/78 1447 3.0 17.2 19.5 8.5 9.2 14 10/3/78 1508 3.0 15.2 18.5 8.4 9.2 15 10/3/78 1600 3.5 22.0 18.7 8.4 9.5 16 10/2/78 1602 4.5 20.6 19.7 8.4 9.4 17 10/2/78 1645 1.5 27.0 20.5 8.6 8.1 I

N R

I

14 TABLE 8.

WATER QUALITY AT EXPOSURE PANEL STATIONS, NOVEMBER, 1978

r ___

Station Date Time in Feet Salinity - o/co Temp. *C 02 Pil 1

11/9/78 0930 6.0 29.1 12.7 10.8 7.9 2

11/9/78 1000 2.0 23.6 11.7 10.2 8.4 3

11/9/78 1030 3.0 24.2 11.3 10.4 8.5 4

11/9/78 1055 3.5 25.6 13.3 9.6 8.5 4A 11/9/78 1107 3.5 23.4 12.3 10.1 8.7 5

11/9/78 1125 4.0 20.2 13.0 11.0 8.7 6

11/9/78

'.135 4.0 19.9 12.4 10.0 8.7 7

11/9/78 1140 3.0 19.9 12.5 10.0 8.5 8

11/9/78 1200 6.0 22.7 12.5 10.0 8.8 9

11/9/78 1220 6.0 24.1 12.5 11.5 8.9 10 11/9/78 1445 3.0 22.0 13.5

'.5 8.8 10A 11/9/78 1345 3.5 23.4 12.5 10.0 9.0 10B 11/9/78 1415 3.5 23.4 12.5 10.0 9.1 11 11/9/78 1430 4.0 25.6 13.0 11.0 9.2 12 11/9/78 1510 3.5 22.0 13.5 10.0 8.9 13 11/9/78 1535 3.0 18.5 14.0 12.5 9.0 14 11/9/78 1600 3.0 23.4 13.5 12.5 9.1 I

15 11/8/78 1620 3.5 17.7 12.0 10.9 8.5 16 11/9/78 1620 4.5 17.7 13.5 11.0 9.1 17 11/8/78 1710 1.5 27.2 12.5 10.8 8.6 I

4 I

m m

m M

M M

M M

TABLE 9.

CONDITION OF GONADS OF TEREDINID EORERS REMOVED FROM EXPOSURE PANELS IN BARNEGAT BAY FROM SEPTEMBER THROUGH NOVEMBER, 1978 EA = Early Active; LA = Late Active; R = Ripe; PS = Partially spawned; M = Malo; F = Female; H = Hermaphrodite Month No. Months Gonad Specimen No.

Station Removed Exposed Species Sex __ Condition Comments 389 7

Sep 78 6

Bankia gouZdi F

PS 390a 7

Sep 78 6

Tcrado bartechi H

PS Larvae in brood pouch, b

Taredo bartcchi H

S c

Tarado bartechi H

R d

Terado bartschi H

PS e

Terado bartcchi H

PS f

Terado bartachi H

PS Leukocytosis; dense connective tissue formation in mantle a

Tcredo bartcchi U

PS h

Tercdo bartschi H

PS Dense connective tissue formation in mantle i

Tgredo hartachi H

S 391a 14 Sep 78 1

Bankia gouldi M

EA

[

b M

EA 392 4

Sep 78 6

Bankia gouldi no discernable gonad 393 17 Sep 78 6

Taredo navalic M

EA 394a 10A Sep 78 5

Bankia gouldi M

P Possibic cysts; leukocytosis b

Bankia gouldi F

S 395 17 Sep 78 12 Terado navalic F

EA Special panel 396 17 Sep 78 12 Bankia gouldi F

S Special panel 397a 5

Sep 78 6

Taredo bartachi No discernable gonad Tarado bartachi H

S Leukocytosis in mantle; abnormal o

nuclei in some leukocytes c

Tarado bartechi No discernable gonad d

Tercdo bartachi H

PS e

Teredo bartcchi H

PS E

Terado bartcchi H

S g

Teredo bartschi No discernable gonad h

Terado bartcchi H

CA i

Terado bartachi No discernable gonad

M M

M M

M M

M M

M M

M M

M TABLE 9.

Continued Mon i.h No. Months Gonad Specimen No.

Station Removed Exposed Sp eci_es Sex Condition Comments 398 2

Sep 78 6

Teredo spp.

No discernable gonad 399a 7

Sep 78 1

Terado hartschi No discernable gonad b

Sep 78 Terado hartschi No discernable gonad 400a 1

Sep 78 6

Terado navalis F

R b

Terado navalic y

a c

Terodo navalis M

PS 401a 4

Oct 78 6

Banhia gouldi No discernable gonad b

Bankia gouldi M

LA Bankia pouldi M

EA Fibrous connectice tissue through-c out gonad area 402a 10A Oct 78 6

Bankia gouldi F

EA Leukocytosis of gonad and under mantle epithelium; mass of necrotic debris in gut area; dense connective tissue b

Bankia gouldi M

EA Bankia gouldi No discernable gonad; cosinophelic 5 c

material in enlarged phagocytes d

Bankia gouldi No discernable gonad 403 5

Oct 78 6

Bankia gouldi F

S 404 15 Oct 78 6

Bankia goulds M

EA 405a 5

Oct 78 6

Terado bartschi H

PS b

Teredo hartachi Larvae in brood pouch; no other discernable gonad c

Teredo M.rtschi H

PS d

Teredo bartschi n

PS e

Terado bartschi H

S 406 4A Oct 78 6

Bankia gouldi F

EA 407 6

Oct 78 6

Teredo hartschs F

PS Larvac in brood pouch 408 17 Oct 78 12 Teredo navalia M

EA Special panel

r.

M M

M M

M M

M M

M M

M M

M M

TABLE 9.

Continued Month No. Months Gonad Specimen No.

Station Remov_e_d Exposed Species Sex Condition Comments 409a 11 Oct 78 6

Bankic pouldi M

EA b

Bankia gouldi No discernable gonad Banhia gouldi M

EA c

d Banhia gculd?

No discernable gonad Bankia gouldi M

EA e

E Bankia gouldi F

LA g

Banhia gouldi M

EA h

Bankia gouldi M

EA i

Banhia gouldi M

EA j

Bankia gouldi No discernable gonad 410a 1

Oct 78 6

Tcredo navalia M

EA Minchinia spores b

Tercdo navalis F

EA

?!inchinia spores c

Terado navalis M

EA flinchinia p1nsmodia d

Terado navalia F

PS Mineninia e

Terado navalis F

EA Minchinia f

Terado navalis M

EA g

Tarado navalia F

EA Minchinia G

h Terado navalis H

LA Minchinia i

Taredo navalis H

EA Minchinia j

Teredo navalis M

EA Minchinia 411a 10B Oct 78 6

Bankia gouldi M

EA Cysts in typhlosole; fibrous connective tissue b

Bankia gouldi F

EA 412a 2

Oct 78 6

Taredo navalis F

EA b

Tcredo navalis F

EA c

Tcredo navalis F

EA 413a 14 Nov 78 6

Bankia gouldi M

EA b

Bankia gouldi M

EA c

Banhia gouldi M

EA d

Bankia gouldi M

EA Bankia gouldi M

EA e

f Banhia gouldi M

EA g

Bankia gouldi M

EA Concentration of fibroblasts in gonad h

Bankia gouldi M

EA i

Banhia gouldi M

EA j

Bankia gouldi M

EA R

Bankia gouldi N

EA

M M

M M

M M

M

+

TABLE 9.

Continued Month No. Months Gonad Specimen No.

Station Removed Exposed Species Sex Condition Comments 414a 7

Nov 78 6

Banhia gouldi M

EA Concentration of fibroblasts b

Bankia gouldi M

EA 415a 7

Nov 78 6

Toredo bartschi H

S b

Terado bartschi H

S c

Teredo bartschi U

PS d

Teredo hartschi H

PS e

Teredo bartschi B

PS f

Terado bartachi H

PS g

Terado bartschi No gonad; larvae in brood pouch h

Teredo bartschi H

PS Ciliates in mantle cavity i

Terado bartachi U

S 416a 13 Nov 78 6

Bankia gouldi M

EA Leukocytosis in digestive gland b

Bankia goulds No discernable gonad. Some sort of grouths in digestive gland area; may be plasmodia but does not resemble Minchinia w

Bankia gouldi M

EA 03 c

d Bankia gouldi M

EA Banhia gouldi M

EA e

f Banitia gouldi M

EA g

Bankia gouldi M

EA 417a 11 Nov 78 6

Bankia gouldi M

EA Leukocytosis.in gonad and typhlosole b

Banhia gouldi M

EA c

Bankia gouldi M

EA d

Bankia gouldi M

EA Banhia gouldi M

EA e

E Bankia gouldi M

EA g

Bankia gouldi M

EA Fragment.ation of typhlosole epithelium h

Sankia gouldi F

LA Eggs undergoing lysis; specimen probably did not spawn 418 11 Nov 78 6

Teredo navalis No discernable gonad; very young specimen O

M M

M M

M M

M TABLE 9.

Continued Month No. Months Gonad Syecimen No.

Station Removed Exposed Species Sex Condition Comments 419a 6

Nov 78 6

Teredo bartschi M

S b

Teredo bartschi M

PS c

Teredo bartschi M

PS d

Teredo bartschi 11 PS e

Teredo bartschi H

PS 420 8

Nov 78 6

Bankia goulds No discernable gonad 421 17 Nov 78 6

Bankia gouldi M

EA 422a 10A Nov 78 6

Bankia gouldi No discernable gonad b

Bankia gouldi M

EA 423a 5

Nov 78 6

Teredo hartschi 11 S

b Teredo bartschi 11 PS c

Teredo bartschi No discernable gonad d

Teredo bartschi 11 R

Possible gregarine in tissue e

Teredo bartschi II PS E

Teredo bartschi n

R w

3 Teredo bartschi No discernable gonad; larvae in brood pouch h

Teredo bartschi No discernable gonad i

Teredo bartschi No discernable gonad; larvac in brood pouch; ciliates in mantle cavity 424 4

Nov 78 6

Bankia gouldi M

EA 425a 17 Nov 78 6

Teredo navalis F

R Minchinia b

Teredo navalis F

LA c

Toredo navalis F

LA Digestive gland necrotic; Minchinia d

Teredo navalis 11 LA Minchinia 426 5

Nov 78 6

Bankia gouldi No discernable gonad; leukocytosis 427a 2

Nov 78 6

Teredo navalis F

LA Eggs being lysed; specimen probably did not spawn b

Teredo navalis H

LA Same as above c

Teredo navalis M

LA Minchinia d

Terado navalis F

LA A

M M

M M

M M

M M

TABLE 9.

Continued Month No. Months Gonad Sy cimen No.

Station Removed Exposed Species Sex Condition Comments 428a 1

Nov 78 6

Teredo navalis F

EA Minchinia; possibic metaplasia of digestive gland h

Teredo navalic F

EA Minchinia c

Taredo navalic M

EA Hinchinia d

Teredo navalis F

EA Ninchinia e

Terado navalic M

EA f

Tarado navalis H

EA Minchinia g

Terado navalia C

EA Minchinia h

Teredo navalis F

EA Minchinia; extensive leukocytosis of gonad area and digestive gland i

Tercdo navalic H

EA Minchinia j

Terado navalis M

LA Minchinia (heavy) k Tercdo navalic F

LA Minchinia 1

Teredo navalis M

LA m

Teredo navalis M

LA n

Toredo navalis H

LA Minchinia o

Toredo navalis M

LA Hinchinia (heavy) yo 429 17 Nov 78 12' Torodo navalis M

EA Special panel. Extremely heavy infection of Minchinia; hyper-plasia and leukocytosis of typhlosole 430 2

Nov 78 12 Torcc.b navalis M

EA Special panel

=-

O