ML19284A899
| ML19284A899 | |
| Person / Time | |
|---|---|
| Site: | Farley, 05000548 |
| Issue date: | 03/07/1980 |
| From: | ALABAMA POWER CO. |
| To: | |
| Shared Package | |
| ML19284A897 | List: |
| References | |
| NUDOCS 8003180438 | |
| Download: ML19284A899 (4) | |
Text
s.
TAbod 1A
~
EFFLUENT AND WASTE DISPOSAL. SEMIANNUAL REPORT 1978 GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES UNIT QUARTER -
' QUARTER
- 3
- 4 A.
Fission & Activation Gases l.
Total release Ci 7.9 E 02 1.1 E 03 2.
Average release rate for period pCi/sec 9.9 E 01 1.4 E 02 3.
Percent of Technical Specification limit 5.3 E-03 4.8 E-03 Note (1) 4.
Percent of Technical Specification limit 9.0 E-03 8.6 E-03 Note (2)
B.
Iodines 1.
Total iodine-131 Ci 2.6 E-05 5.3 E-6 2.4 E 07-2.
Average rele se rate for period pCi/sec 3.3 E-06 6.B E ~1 3,0
^ &_.
3.
Percent of 'lahnical Specification limit 1.0 E-08 Z.1 E-9
^ 1 C 11 Note (3)
C.
Particulates 1.
Particulates with half-lives >8 days C1 4.1 E-02 3.2 E-05 2.
Average release rate for period pCi/sec 5.2 E-03 4.1 E-06 3.
Percent of Technical Specification limit 1.9 E-03 1.6 E-06 Note (3)
D.
Tritium 00 1.
Total release Ci 5.3 E 01 7.3 E 00 e
2.
Average release rate for period pCi/sec 6.6 E 00
- 9. 2E-01 w
3.
Percent of Technical Specification limit 6.2 E-07 1.2 E-07 00 C
C-Notes:
(1) Whole Body Release Rate Liuit (<500 mrem /yr)
(2) Extremity Release Rate Limit (<3,000 mrem /yr)
(3) 6.3 mrem /yr Inhalation Dose
tau.E IB
^
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1978 GASEOUS EFFLUENTS-ELEVATED RELEASE l
CONTINUOUS H0DE BATCN HODE NUCLIDES RELEASED UNIT QUARTER QUARTER QUARTER QUARTER
- 3
- 4
- 3
- 4
- 1. Fission gases Krypton-85 Ci 3.1 E 00 7.5 E-01 8.1 E-01 0.0 Krypton-85m Ci 0.0 0.0 2.7 E-02 0.0 Krypton-87 Ci 0.0 0.0 6.0 E-04 0.0 Krypton-88 Ci 0.0 0.0 1.4 E-02 0.0 Xenon-133 Ci 5.7 E 02 1.8 E 02 8.9 E-00 5.5 E-01 Xenon-135 Ci 4.2 E 01 1.2 E 00 5.7 E-01 4.4 E-04 Xenon-135m Ci 0.0 0.0 0.0 0.0 Xenon-138 Ci 0.0 0.0 1.8 E-04 0.0 Argon-41 Ci 7.4 E 01 1.7 E 01 5.4 E-03 1.6 E-02 Xenon-137 Ci 0.0 0.0 1.3 E-03 0.0 Krypton-90 Ci 0.0 1.6 E-02 0.0 0.0 Xenon-133m Ci 6.0 E-00 3.1 E-01 1.1 E-01 0.0 Krypton-89 Ci 0.0 0.Q 0.0 0.0 Xenon-131m Ci 1.7 E-01 0.0 1.4 E-01 4.9 E-02 Total for period 7.1 E 02 2.0 E 02 1.1 E-01 6.2 E-01
- 2. Iodines Iodine-131 C1 2.6 E-05 0.0 5.0 E 0.0 5.2 E-06 lodine-133 Ci 2.6 E-07 0.0 0.0 0.0 Total for period' Ci 2.6 E-05 0.0 - 0. 0 E -06 0.0 '
5.2 E-06
TL.E IC EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1978 CASE 0US EFFLUENTS-GROUND-LEVEL RELEASES CONTINUOUS MdDE -
BATCl! MODE NUCLIDES RELEASED UNIT QUARTER QUARTER QUARTER QUARTER
- 3
- 4
- 3
- 4
- 1. Fission gases Krypton-85 Ci 6.4 E-01 1.4 E 01 8.3 E-03 0.0 Krypton-85m Ci 0.0 0.0 6.6 E-04 0.0 Krypton-87 Ci 0.0 0.0 1.5 E-05 0.0 Krypton-88 Ci 0.0 0.0 3.4 E-04 0.0 Xenon-133 Ci 2.2 E 01 8.2 E 02 2.0 E-01 2.3 E-02 Xenon-135 Ci 2.5 E 00 2.6 E 01 1.4 E-02 7.5 E-05 Xenon-135m Ci 0.0 0.0 0.0 0.0 Xenon-138 Ci 0.0 0.0 4.6 E-06 0.0 Argon-41 Ci 2.3 E 01 5.6 E 01 1.1 E-04 2.3 E-03 Xenon-137 Ci 0.0 0.0 3.4 E-05 0.0 Krypton-90 Ci 0.0 2.6 E-01 0.0 0.0 Xenon-133m Ci 2.1 E 01 9.1 E 00 2.6 E-03 0.0 Krypton-89 Ci 0.0 0.0 0.0 0.0 Xenon-131m Ci 4.6 E-02 0.0 3.1 E-03 1.6 E-03 Total for period Ci 7.0 E 01 9.3 E 02 2.3 E-01 2.7 E-02
- 2. Iodines Iodine-131 Ci 4.5 E-08 0.0
'.0 E 08 0.0 5.0 E-08 Iodine-133 Ci 2.9 E-10 0.0 0.0 0.0 Total for period Ci 4.5 E-08 0.0 4.C E-08 0.0-5.0 E-08 e
TA.2 2A e
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT 1978 LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES
~
~ QUARTER
' QUARTER UNIT 03
- 4 A.
Fission & Activation Products 1.
Total release (not including tritium, gases, alpha)
Ci 9.0 E-03 5.9 E-02 2.
Average diluted concentration during period Note (1) pCi/ml 8.3 T.-10 5.1 E-09 3.
Percent of applicable limit 2.2 E-03 8.2 E-03 B.
Tritium 1.
Total release Ci
- 7. 2 E O 2.
- 7. 2 E 4.4 E-02 2.
Average diluted concentration during period Note (1) pCi/ml 6.6 E-05 3.8 E-09 3.
Percent of applicable limit 2.2 E 00 1.3 E-04 C.
Dissolved and entrained gases 1.
Total release ci 5.3 E-02 7.8 E-03 2.
Average diluted concentration during period Note (l) pCi/ml 4.9 E-09 6.8 E-10 3.
Percent of applicable limit 1.2 E-02 1.7 E-03 D.
Gross alpha radioactivity 1.
Total release Ci 0.0 0.0 E.
Volume of waste released (prior to dilution) liters 3.6 E 07 5.0 E 07 F.
Volume of dilution water used during period Note (1) liters 1.1 E 10 1.1 E 10 NOTE:
(1) During period of discharge
.