ML19284A691

From kanterella
Jump to navigation Jump to search
Forwards QA Program Insp Rept 99900316/78-01 on 781113-16 & Notice of Deviation
ML19284A691
Person / Time
Issue date: 12/11/1978
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Kunka S
GOULD, INC.
Shared Package
ML19284A687 List:
References
REF-QA-99900316 NUDOCS 7903150206
Download: ML19284A691 (2)


Text

[pn Mai <

UNITED STATES V

o NUCLEAR REGULATORY COMMISSION b. E,%

Oe REGION IV b

611 RYAN PLAZA ORIVE, SUITE 1000 k

'd

[

ARLINGTON, TEXAS 76011 p

g <> j 110EC 1973 Docket tio. 99900316/78-01 Gould Incorporated Valve and Fitting Division ATTf{: Mr. S. M. Kunka Vice President, Operations 6300 W. Howard Street Chicago, Illinois 60648 Gentlemen:

This refers to the QA Program inspection conducted by Mr. R. E. Oller of this office on fiovember 13-16, 1978, of your facility at Chicago, Illinois, associated with the manufacture of nuclear valves and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.

This inspection was made to confirm that, in the areas inspected, your QA Program is being effectively implemented. The inspection effort is not designed to assure that unique quality requirements imposed by a customer are being implemented; nor to assure that a specific product, component or service provided by you to your customers, is of acceptable quality. As you know, the f1RC requires each of its licensees to assume full responsibil-ity for the quality of specific products, components or services procured from others. You should therefore not conclude that the flRC's inspection exempts you from inspections by an f1RC licensee or his agents nor from taking effective corrective action in response to their findings.

Areas examined and our findings are discussed in the enclosed report.

Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection it was found that the implementation of your QA Program failed to meet certain f1RC requirements. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within thirty (30) days of your receipt of this report a written statement containing, (1) a description of steps that have been or will be taken to correct these items, (2) a description of steps that have been or will be taken to prevent recurrence, and (3) the date your corrective actions and preventive measures were or will be completed.

7 9 0 315 0dofo

Gould Incorporated In accordance with Section 2.790 of the Commission's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter with enclosure and your reply, together with the enclosed inspection report will be placed in the Commission's Public Document Room.

If this report contains any information that you believe to be proprietary, it is nec-essary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the.easons on the basis of which it is claimed that the infonnation is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.

If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have an;,Jestions concerning this inspection, we will be pleased to discuss them with you.

Sincerel C

?

g d{, f f C

Uldis Potapovs, Chief Vendor Inspection Branch

Enclosures:

1.

Notice of Deviation 2.

Inspection Report No. 99900316/78-01 cc: Mr. D. Takada, Assistant QA Manager

.