Form NRC418 U.S. NUCLEAR REGULATORY CoMMISSICN U E' CE TIFICATE OF COMPLI ANCE 10 C R M For Radioactive Materia!s Packages 1.fa) Certificate Numter 1.!b) Revision No.
1.(c) Package fcentification No.
1.(d ) PMes No. 1.(e) T tal No. Pagt 9090 2
USA /9090/A 1
3
- 2. PREAMBLE 2.(a)
This cr tificate is issued to satisfy Sections 173.333a,173.394,173.395. and 173.396 of the Cecartrrent of Trantoortation dazardo Materials Regulations f 49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Ceoartment of Transportation Cangeroi s Cargoes Regulations (46 Cc R 146 1 *M. as arrenced.
2.(b)
The pacxaqing and contents described in item 5 below, meets the safety standaros set forth in Subcart C of itte 10. Ooce of Faderal Regulations, Part 71, "Pacxaqing of Racicactive Materiais for Transoort and Transoortatio.: of Rat.. active Matenal Under Certain Conditions.
2.(c)
This certificate does not relieve the consignor from compliance with any recuirement of the regulations of the U.S. Cecartrnent of Transportation or other acosicable regulatory agencies, including the government of any country througn or into whicn the pacxage will be transported.
- 3.
- hrs cartrficate is issued on the bssis of a safety analysis report of the package design or acosicatiorW 3.(a)
Prepared by Clame.cd address):
3.ib)
Title and k2entification of report or acclication:
Allied Chemical Corporation Allied Chemical Corporation application P.O. Box 430 dated May 18, 1977, as supplemented.
Metropolis, Illinois 62960 3.(c)
Docxet No. 71-9090 4 CONDITloNS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Cescription of Packaging and Authorized Contents, Medel Numcer, Fissde C: ass Cther Conditions, and
References:
(a) Packaging (1) Models Nos.:
(2) Description Metal 48-inch UFs cylinder.
Gross weight nominal 30,150 lbs.
(3) Drawing The 48 OM packaging is as described and constructed in accordance with Allied Chemical Corporation Drawing No. 515172, Revision B and Job Specification JSP-226, dated March 4,1966, revised January 24, 1967. The 48 H packaging is described and constructed in accord-ance with Union Carbide Corporation Drawing No. E-M-14864-A, Revision B, and Equipment Specification No. ES-CMD-14864-1, Revisior. 0, dated September 29, 1978. The 48 HX packaging is as described and constructed in accordance with Union Carbide Corporation Drawing No. E-M-14864-6, Revision 0, and Equipment Specification
'No. ES-CMD-14864-2, Revision 0, dated February 20, 1979.
(b) Content (1) Type and form of material Uranium hexafluoride (UF;) in solid form which meets the requirements as low specific activity material as defined in 10 CFR 571.4(g).
4904040233
Page 2 - Certificate fio. 9090 - Revision ilo. 2 - Docket tio. 71-9090 5.
(b) Content (continued)
(2) Maximum quantity of material per package Maximum U-235 enrichment, pounds UFs, and U-235: content for the cylinder model as follows:
Max. Enrichment w/o Max. UFs
!4ax. U-235 U-235 Pounds
.kos l.0 27,030 82.9 6.
Valve protectors shall be provided as described in OR0-p51, Rev. 3.
7.
The fabrication (new packagings only), assembly (new packagings only), testing, maintenance, and use of packagings shall be in accordance with the requirements of CRO-651, Rev. 3 except that design shell thickness is 5/16", minimum allowable shell thickness is 1/4", and the routine hydrostatic test is to be performed at 200 lb/sq in. Materials of construction for the 48 OM packaging are given in Job Specification JSP-226 and for the 48 H packaging in Equipment Specification fio. ES-CMD-14864-1, Revision fio. 0 (alternate A285 steel not authorized).
8.
The Model fio. 48 HX packaging shall be transported only.when a-determimtion has been made by the shipper that the average daily temperat2re or ambient temperature during the shipment will not be less than 30 F a1d the temperature of the contents at the time of delivery to carrier for.trans] ort is at least 30 F.
9.
The package shall be transported on a motor vehicle, railroaa car, aircraft, inland water craft, or hold or deck of a seago,ing sessel assigned for the sole use of the shipper.
- 10. The package authorized by this Certificate of Compliance.is hereby approved for use under the general license provisions of.10 CFR 171.12(b).
- 11. Expiration date: May 31, 1982.
~
Page 3 - Certificate ilo. 9090 - Revision fio. 2 - Docket No. 71-9090 REFEP.EriCES Allied Chemical Corporation application dated May 18, 1977.
Jranium Hexafluoride Handling Procedures and Container Criteria, OR0-651, Rev. 3, August 1972.
Testing of Ten-Ton Uranium Hexafluoride Cylinders, KY-500, October 22, 1965.
Testing of Fourteen-Ton Uranium Hexafluoride Cylinders, KY-549, fiay 15,1968.
Additional Reference Required for the Model No. 48 H Packaging Department of Energy Supplement Dated: January 5,1979.
Additional Reference Reouired for the Model No. 48 HX Packaging License Application for Type 46 9X Cylinder for Shipment of Natural Assay UF-6, KY-697, February 26, 1979.
FOR THE U.S. NUCLEAR RE.iULATORY C0fotISSION
();
Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety 79 Date: