05000267/LER-1979-005-03, /03L-0 on 790209:during Semiannual Loss of Outside Electrical Power Test,Output Circuit Breaker Did Not Close.Cause Unknown.Breaker Replaced W/Equivalent Spare

From kanterella
(Redirected from ML19282C165)
Jump to navigation Jump to search
/03L-0 on 790209:during Semiannual Loss of Outside Electrical Power Test,Output Circuit Breaker Did Not Close.Cause Unknown.Breaker Replaced W/Equivalent Spare
ML19282C165
Person / Time
Site: Fort Saint Vrain 
Issue date: 03/09/1979
From: Gahm J
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19282C162 List:
References
LER-79-005-03L, LER-79-5-3L, NUDOCS 7903210125
Download: ML19282C165 (5)


LER-1979-005, /03L-0 on 790209:during Semiannual Loss of Outside Electrical Power Test,Output Circuit Breaker Did Not Close.Cause Unknown.Breaker Replaced W/Equivalent Spare
Event date:
Report date:
2671979005R03 - NRC Website

text

nm I.lCENSEE EVENT REPORT CONTROL sLoCx:

I I

l l

l@

(PLEASE PRINT OR TYPE ALL REQUIRED INPORMATIOM 6

l C l 0 l F l S l V l 1 l@150l0l-l0l00 l 0 l 0 l-l 0 l 0 l@l 4 1 l1 l 2 l 0 l@l l

l@

0 t

9 UCENSEE CODE 14 uCENSE NUM8ER 25 26 UCENSE TYPE 40 57 CAT 58 7

8 CON'T

"' " l L gl 0 l 5 l 0 l 0 l 0 l 2 l 6 l 7 @l 0 l 2 l 0 l 9 7l9l@l0l3 0l9l7l9l@

C 1

uRCE 7

8 60 St DOCKET NUMSER 68 69 EVENT D ATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h O

2 While the plant was in a shutdown condition and the semi-arnual loss o f outside,

1 l electrical power test was being performed, diesel generator 1A output circuit breaker i 0 2 l did not close. This is a violation of LCO 4.6.l(3) and is reportable per Fort St.

O 4

l Vrain Technical Spe:cification AC 7.5.2(b)2.

I i

O s

l IOTs'l l I

6 l'5T71 I I

O 8

l 80 7

8 9 SUSEo'u

$$E)E SoI)*E YOTE SU8$5E COMPONENT COoE R

lE l Dl@ W@ W@ lC lR lT lB lR lK lh y@ W @

7 8

9 10 13 12 13 18 19 20

  • SEQUENTIAL OCCURRENCE REPORT REVISION LER EVENT YEAR R EPORT NO.

CODE TYPE NO.

@,aeg/RO [719 l l--J 101015 l y

0 13 l W

[_j O

21 22 23 24 26 27 28 29 30 31 32 KN O P 7

METH HOURS S8 i FOR 8.

SU UE MA UF RER l C l@(,D_l@

lZl@

W@

l0l0l0l0l W@

l Nl@

lN l@

lI l2 l0 l2 l@

33 34 35 36 31 40 41 42 43 44 47 CAUSE DESCRIPY10N AND CORRECTIVE ACTIONS h i

O One ITE model K-1600 circuit breaker failed to close.

Cause undeternined.

Breske r l

1 i l replaced with an equivalent spare.

t 2 I LL.L.J l i 4 L__

l 7

8 9 80 STA

% POWER OTHER STATUS 01 O Y

DISCOVERY DESCRIPTION y

Dl@ l0 l 0 l 0 l@l N/A l

l B l@l Surveillance Test l

ACTIVITY CO TENT AMOuNTO, ACTIVITY @ l LOCATION OF RELEASE @

RELEASt@o OP RETE 4SEglN/A N/A l

[,,Zj 1

6 7

8 9 10 11 44 46 80 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

[W l 0l 0 l 0 l@l Z l@l N/A l

PERSONNEL tNJU IES NUMBER

DESCRIPTION

l0l0l0l@l N/A 1

a 7

8 9 11 12 80 LOSS OF OR DAMAGE TO FACILITY TYPE

DESCRIPTION

Q @@l N/A l

80 7

8 9 10

    • "L'7CRi, TION @

7903210125-NRc use ONLY uL.ILN_l81

,SSUE N/A I

I IIIIIIIIIIIi 68 69 80 3 7

8 9 10

/g J. W.

Gahm PHONE: (303) 785-2253 2

NAME OF PREPARERu