<-f REGION til
' c 799 ROOSEVELT ROAD GLEN E LLYN, ILUNotS 60137 Docket No. 50-358 MR -6.1979 Cincinnati Gas and Electric Company ATTN:
Mr. Earl A. Borgmann Vice President Engineering Services and Electrical Production 139 East 4th Street Cincinnati, OH 45201 Gentlemen:
Thank you for your final report dated January 19, 1979, pursuant to 10 CFR 50.55(e) regarding tolerance of alignment pins welded into the reactor pressure vessel core support plate.
With respect to your straightening of the bent pins, we have no further questions regarding acceptability. This position was established in our report No. 50-358/79-01. That same report, however, identified three pins that were repaired prior to taking measurements. No justification was presented in your report that would alter our stated position that these should be replaced. This matter will be reviewed during future inspections.
Your cooperation with us is appreciated.
Sincerely, s
G. Fiorelli, Chief Reactor Construction and Engineering Support Branch cc:
J. R. Schott, Plant Superintendent Central Files Reproduction Unit NRC 20b PDR Local PDR NSIC TIC U. Young Park, Power Siting Commission Citizens Against a Radioactive Environment 70031603R
,