ML19282A857

From kanterella
Jump to navigation Jump to search
IE Insp Rept 70-398/78-02 on 781212-15.No Noncompliance Noted.Major Areas Inspected:Nuclear Matl Control & Accounting,Including Matl Control Areas,Physical Inventory & Records & Repts
ML19282A857
Person / Time
Site: 07000398
Issue date: 01/08/1979
From: Cohen I, Della Ratta A, Joyner J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19282A854 List:
References
70-0398-78-02, 70-398-78-2, NUDOCS 7903070204
Download: ML19282A857 (8)


Text

'

U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region I Report No.

70-3o8/78-02 Docket No.70-398 Safeguards Group:

2 License No. SNM-362 Priority Category Ur; Pu Licensee:

U.S. Decartment of Commerce National Bureau of Standards Washinaton, D.C.

20234 Facility Name:

National Bureau of Standards Inspection at:

Gaithersburg, Maryland Inspection conducted _ December 12-15, 1978

[I

\\

Inspectors:

I. Cohen, Chemist data signed Olla lbb

)

f> - 7 7 A. Della Ratta,I bitop date signed Au m

cate signed NW

/-B-79 Approved by:

o J. H. Joyneschief, Nuclear Material Control date signed Support Section, Safeguards Branch Inspection Summary:

Insoection on December 12-15, 1978 (Report No. 70-398/78-02)

Areas Inspected:

Routine, unannounced inspection by regional based inspectors of nuclear material control and accounting, including:

organization; material control areas; physical inventory and records and reports.

The inspection involved 64 inspector-hours onsite by two regional based NRC inspectors.

Results: No items of noncompliance were identified.

Region I Form 12 7903070 AOV (Rev. April 77)

DETAILS 1.

Persons Contacted W. P. Reed, Standards Coordinator F. J. Shorter, Physical Science Administrator

  • T. Hobbs, Health Physicist
  • A. Schwebel, Chief, Health Physics Section L. Coker, Secretary and Bookkeeper K. C. Ouvall, Physicist The inspectors also interviewed other licensee employees including members of the nuclear material control group and scientists.
  • denotes those present at the exit interview.

2.

Organization The inspector reviewed the origanization structure as shown within the licensee's Fundamental Nuclear Material Control Plan (FNMC) and compared the stated structure to the current practice.

All nuclear material control and management positions were filled as stated.

The licensee maintains a training program for all nuclear material personnel and training sessions have documented as to subject of training, number of hours and attendees by the accountability office. All nuclear material personnel affirmed that they were attending training sessions.

No items of noncompliance were identified.

3.

Material Control Areas The licensee maintains two material balance areas and three item control areas as stated in the FNMC Plan. Material Control in each of these areas was maintained by a different licensee employee and custodial responsibility was issued in writing by licensee management.

The inspector observed that each custodian maintained a ledger which showed current inventory, receipts and removals.

Audit of the ledger revealed no discrepancies.

No items of noncompliance were identified.

3 4.

Physical Inventory The inspector reviewed physical inventory records which showed that inventories were performed at 60-day frequencies for the period July 1977 through flovember 1978.

The inventory records documented that inventories were taken by teams.

Checks of the accuracy of the inventory ware performed by the inspectors by independently reconciling the September 27, 1978 physical inventory.

The in-ventory listing was compared with the material types summarized by the licensee and no differences were noted.

The inspector, using the inventory taken on November 27, 1978, performed item iden-tifications to provide assurance that items listed on the physical inventory were present at the licensee's facility.

All items selected were located and id ntified.

These item verifications were performed in each of the five control areas.

No items of noncompliance were identified.

5.

Records and Reports The inspectors audited d.e material control and accounting records and reports for the material balance periods April 1,1977 -

September 30, 1978.

Based on a facility tour and audit of licensee records, it was determined that the licensee has confined his possession and use of special nuclear material to the locations and purposes authorized by his license.

The Nuclear Material Trans-action Reports (Form NRC/ERDA-741) documenting receipts and ship-ments were reviewed for proper signatures, timeliness, format and accuracy of content.

The same tests were performed on measured discard and loss reports. Material Status Reports (Form NRC/ERDA-742) submitted for the periods ending September 30,1977, March 31, 1978 and September 30, 1978 were also reviewed in the same manner.

Results were then traced to the licensee records and the DOE-NMMSS computer tabulations.

The licensee reconciled and adjusted the book inventory to the results of the physical inventories performed during the periods under review, as required by regulation.

Also, it was determined that the licensee's physical inventory totaled less than the authorized possession limits.

4 Exhibits I-IV attached to this report cover the material activity summary for the inspection period.

No items of noncompliance were identified.

6.

Exit Interviews An exit interview was conducted on December 15, 1978 with attendees shown in Paragra'ih 1.

Licensee representatives were informed of the scope and findings of the inspection.

EXHIBIT I National Bureau of Standards SNM-362 70-398 Material Balance Summary 9/30/78 4/1/77 ENRICHED URANIUM RIS:YBC Grams Element Isotooe Beginning Inventory 0 4/1/77 6939 1623 Receipts 954 923 Material to Account For 7893 2546 Removals:

Shipments 423 90 Inventory Difference Ending Inventory 0 9/30/78 7470 2456 Material Accounted For 7893 2546

EXHIBIT II flational Bureau of Standards70-398 SNM-362 Material Balance Summary 4/1/77 9/30/78 Plutonium RIS:YBC Grams Element Isotoce Beginning Inventory 0 4/1/77 98P.

922 Receipts 266 249 Material to Account For 1248 1171 Removals:

Shipments 402 283 Inventory Difference (Rounding) (2)

Ending Inventory 0 9/30/78 846 790 Material Accounted For 1248 1171

EXHIBIT III National Bureau of Standards

,0-398 SNM-362 Material Balance Summary 4/1/77 9/30/78 Uranium-233 RIS:YBC Grams Element Isotoce Becinning Inventory 9 4/1/77 5

5 Receipts

-0,-

- 0,-

Material To Account For 5

5 Removals:

Shipments Ending Inventory @ 9/30/78 5

5 Material Accounted For 5

5

EXHIBIT IV National Bureau of S+andards70-398 SNM-362 Material Balance Summary 4/1/77 9/30/78 Plutonium-238 RIS:YBC Grams Element Isotooe Beginning Inventory 0 4/1/77

  • I
  • I Receipts 11.70 9.30 Material to Account For 11.70 9.30 Removals Ending Inventory 0 9/30/78 11.70 9.30 Material Accounted For 11.70 9.30 1 = Microgram