Text

.

Form NRC418 U.S. NUCLEAR REGULATORY CoMMISS!CN

[c[g y 2 33 CEflTIFICATE OF CCMPLIANCE For Radioactive Materials Pacxages 1.(a) Certificate Numcer 1.(b) Revision No.

1.(c) Picxage toentification No.

1.!d) P3ges No. 1.(e) Total No. Page 6058 4

USA /6058/B( )

1 3

2. PREAMBLE 2.f a) This certificate is issued to satisfy Sections 173.333a.173.394.173.395, and 173.336 of the Oecartrrent of Transpor ation Hazarcos Materials Regulations (49 CFR 170-139 and 14 CFR 103) and Sections 146-.19-1Ca and 146-19-100 of the Cecar ment of Transportation Cangerous Cargoes Regulations (46 CFR 146-149), as amenced.

2.!b)

The pacxaging and contents described in item $ below, meets the safety standards set fcrth in Subcart C of Titfe 10. Code of F'soeral Regulations. Part 71, Packaging of Radicactive Materiads for Transport and Transportation of Racicactive Yaterial Under Certain Conditions."

2.tc)

This certificate does not relieve the consignor from correliance with any requirement of the regulations of the U.S. Cecartment of Transcortation or other applicaole regulatory agencies, incluoing the government of any country threugn or into wnicn the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the pacxage design or acclicatiore-3.la)

Prepared by (Name a::d address):

3.(b)

Title and identification of report or acetication:

Teledyne Energy Systems Protective Packaging, Inc., application 110 West Timonium Road dated March 4,.1974, as supplemented.

Timonium, MD 21093 3.fe)

Cocket No. 71-6058 4 CONCITIONS This certificate is ccnditional upon the *ulfilling of the requirements of Subcart o of to CFR 71, as acclicacle, and the conditions specifies in item 5 below.

S. Cescription of Packaging arks Authorized Contents, Model Numcer FissJe Class, Cther Conditions. and

References:

(a) Packaging (1) Model No.: B3-1 (2) Description The packaging consists of a lead shielded steel ~weldment in the shape of a right hollow cylinder with a bottom and a recessed, plugtype gasketed and bolted lid.

The packaging provides a minimum of 6 inches of lead shielding.

Packaging feactures include lifting and tie-down devices and a drain to the central cavity.

The maximum weight of the loaded packaging is 30,000 pounds.

The outer shell is of a laminated steel constructed and is 41 inches ia diameter and 57 inches high.

The two laminates are of plate material 1/2-inch and 1/4-inch in thickness.

The inner shell is of 1/2-inch thick steel plate. The internal cavity dimer.sions are i

26-1/2 inches in diameter and 43 inches high.

The lid is of the I

same construction as the sides and bottom and is secured to the body of the packaging by twelve,1-1/4-inch diameter by 2-inch long hign strength bolts.

7905250226

Page 2 - Certificate No. 6058 - Revision No. 4 - Docket No. 71-6058 5.

(a) Packaging (continued)

(3) Drawing The packaging is as described and constructed in accordance with Battelle Memorial Institute Drawing No. 9958-3501-0001E, Revision B or Revision C.

(b) Contents (1) Type and form of material (i) Byproduct material as solids, non-powder, and dry, which will not decompose at temperatures up to 500 F, packaged within DOT Specification 17H steel drums or equivalent.

(ii) Byproduct material which meets the requirements of special form given in 10 CFR 571.4(o).

(iii) Byproduct and uranium enriched in the U-235 isotope, U-233 or plutonium as solids, non-powder, and dry, which will not decompose at temperatures up to 500 F and packaged within DOT Specification 17H steel drums or equivalent.

(iv) Byproduct and uranium enriched in the U-235 isotope, U-233 or plutonium which meets the requirements of special form given in 10 CFR 571.4(o).

(2) Maximum quantity of material per package Not to exceed 400 watts thermal decay and for the fissile contents described in 5(b)(1)(iii) and 5(b)(1)(iv) not to exceed the following:

Fissile Maximum per Maximum Material Package (crams)

H/X U-235 350 500 U-233 200 450 Pl u to ni um*

200 800 or pro-rated mixtures such that the sum of the ratios of the quantity of each fissile material to its maximum per packaging does not exceed unity.

  • Plutonium in excess of 20 curies per package must be in the form of reactor fuel elements, metal, or metal alloy.

Page 3 - Certificate No. 6058 - Revision :10. 4 - Docket No. 71-6058 5.

(c) Fissile Class II For the contents described in 5(b)(1)(iii) and 5(b)(1)(;/) and limited in 5(b)(2):

Minimum transport index to be shown on label 10.0 6.

For gama-emitting special form materials, at least 5 inches of additional lead shielding must be added as a lining on all sides within the internal cavi ty.

7.

The total weight of the contents including additional lead shielding as may be required shall not exceed 9,000 pounds.

8.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date: December 31, 1979.

REFERENCES Protective Packaging, Inc. application dated March 4,1970 Supplement dated: August 12, 1974 Battelle Columbus Laboratories letter dated April 12, 1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Yr' 1A l 9 v

Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety APR 2 71979 Date:

.