- p**EGoq UNITED STATES 3
).n g
NUCLEAR REGULATORY COMMisslON
'j W ASHINGTON. D.
C.
20555 f
APR 2 41979 FCTR: RHO 71-6744 Those on attached list Gentlemen:
Enclosed is Certificate of Compliance No. 6744, Revision No. 2, for the 140 del ilo. Poly Tiger shipping package. This certificate supersedes, in its entirety, Certificate of Compliance Ib. 6744, Revision No.1, dated ilarch 29, 1977.
Changes made to the enclosed certificate are indicated by vertical lines in the margin.
Those on tr.e attached list have been registered as users of this package under the general license provisions of 10 CFR 571.12(b) or 49 CFR 5173.393a.
This approval constitutes authority to use this package for shipment of radioactive material and for the package to be shipped in accordance with the provisions of 49 CFR 5173.393a.
Sincerely,
[
Charles E. liacDonald, Chief Transportation Branch Division of Fuel Cycle and I4aterial Safety
Enclosure:
As stated cc: w/ encl Richard R. Rawl Q1partment of Transportation 7905090087
Model flo. Poly Tiger Packaging USA /6744/B(
)
Addressees w/ encl Ltr dtd:
Arkansas Power & Light Company Rockwell International ATTil:
Mr. Daniel H. Williams ATTil:
Dr. M. E. Remley P.O. Box 551 P.O. Box 309 Li ttle Rock, AR 72203 Canoga Park, CA 91304 Battelle Columbus Laboratories Sacramento Mun. Util. Dist.
ATTil:
fir. Harley L. Toy ATTil:
Mr. Roger I. Miller 505 King Avenue Route 1, Box 550 Columbus, OH 43201 Herald, CA 95638 Boston Edison Company Teledyne Energy Systems ATTil:
Mr. G. Carl Andognini ATTil:
Mr. John W. McGrew 800 Boylston Street 110 West Timonium Road Boston, MA 02199 Timonium, MD 21093 Consumers Power Company Virginia Electric & Power Co.
ATTtl:
Mr. David Bixel ATTil:
Mr. W. L. Proffitt 212 West Michigan Avenue P.O. Box 26666 Jackson, MI 49201 Richmond, VA 23261 Dairyland Power Cooperative ATTil:
Mr. R. E. Shimshak P.O. Box 135 Genoa, WI 54632 Metropolitan Edison Co.
ATTil:
Mr. M. R. During P.O. Box 542 Reading, PA 19603 flebraska Public Power District ATTil: fir. Jerry V. Sayer P.O. Box 98 Browrville, NE 68321
. Form NRC418 U.S. NUCLEAR REGULATORY COMMISSICN CERTIFICATE OF COMPLI ANCE 10 C R n For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.
1.(c) Pacuage Identification No.
1.(d ) Pages No. 1.(e) Total No. Page 6744 2
USA /6744/B( )
1 3
- 2. PRE AMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a,173.334,173.395, and 173.396 of the Cecartrrent of Transportation Hazardot Materials Regulations (49 CFR 170180 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Cangerous Cargoes Regulations (46 CF R 146--149), as amendexj.
3.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Urvu Certain Conditions.**
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or oth er applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.t a)
Prepared by (? lame and address):
3.(b)
Title and identificatinn of report or application:
Teledyne Energy Systems Protective Packaging, Inc. application dated 110 West Timonium Road March 25, 1975, as supplemented.
Timonium, MD 21093 3.tc) oocket No.
7].6744 4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicaole, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, other Conoitions, and
References:
(a)
Packaging (1) Model No.
Poly Tiger (2) Description The packaging consists of an overpack which provides thermal and impact resistance for an inner shielded cask.
Each packaging con-sists of an outer overpack of two concentric right circular steel cylinders with the annulus filled with 5 to 9 inches of poly-urethane foam (U-2333) on the sides and 10.5 to 19 inches at the ends.
The overpacks are split in the middle and joined by flanged closures to completely enclose the lead shielded inner cask.
The inner cask consists of right circular cylinder with steel-encased lead shielding and bolted, neoprene gasketed closure.
Three overpacks and six shielded casks comprise the authorized Poly Tiger packaging.
Dimensions and maximum weights of the three overpacks are as follows:
Overpack Dimensions Gross Weight (lbs) 32340-1 79.5" dia. x 105.7" high 35,000 32340-2 77.7" dia. x 100.4" high 35,000 32341 38.5" dia. x 76.5" high 6,500 WWW
Page 2 - Certificate No. 6744 - Revision No. 2 - Docket No. 71-6744 5.
(a)
Packaging (continued)
(3)
Drawings The overpacks and shielded casks are constructed in accordance with the following Protective Packaging, Inc. Drawings Nos.-
Package Overpack Shielded Cask 1
32340-1, Rev. B 32216-3, Rev. D 2
32340-1, Rev. B 32216-4, Rev. D 3
32340-2, Rev. B 32216-1, Rev. D 4
32340-2, Rev. B 32216-2, Rev. D 5
32340-2, Rev. B
- 32133, Rev. B 6
- 32341, Rev. B
- 32151, Rev. A (b) Contents (1) Type and form of material Radioactive material, as solids or liquids, in normal or special form within lead shielded casks which are enclosed in an appropriate overpack.
(2) Maximum quantity of material per package Thermal decay hea't not to exceed 10 watts for solids that will not decompose at temperatures up to 300 F and 5 watts for liquids and other solids.
Fissile material content not to exceed the generally licensed mass limits and Fissile Class speci fied in 10 CFR 571.11.
6.
Shipment of liquids where freezing may be encountered is not authorized.
7.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
8.
Expiration date:
August 31, 1980.
Page 3 - Certificate flo. 6744 - Revision flo. 2 - Docket flo. 71-6744 REFERENCES Protective Packaging, Inc. application dated flarch 25, 1975.
Supplement dated: July 21, 1975.
FOR THE U.S. I!UCLEAP, REGULATORY COMMISSION I
k C iar es E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Mdterial Safet.
Date:
.