an men.
UNITE D STATES
[
o NUCLEAR REGULATOHY COMMISSION
[*
REGION IV 5 'I E
Gil RYAN PLAZA DRIVE, SUITE 1000 E
%...../
2 2 Vi ?]l9 Docket No. 99900267/78-02 TRW Mission Manufacturing Company A Division of TRW Incorporated Attn: Mr. P. J. Koen Vice President and General Manager P. O. Box 40402 Houston, Texas 77040 Gentlemen:
Thank you for your letters of December 28, 1978, January 22, 1979, and February 12, 1979, in response to our letters dated November 22, 1978 and December 22, 1978.
As a result of our review, we find that additional information is needed relative to Item C.
Specifically, in regards to sub-Item 1 in Item C, please describe anat actions have been or will be taken to assure identification of pins by heat code, rather than the material type notation observed by the inspector.
Please provide this additional information within twenty (20) days in order that we may complete,our review.
Sincerely, sb /h')
AE
[ Uldis Potapovs, Chief 0
Vendor Inspection Branch U
70042600/o