e" "*0 UNITED STATES
', [p 0g[$
NUCLEAR REGULATORY COMMISSION j
REGION I
- 3 ;s.
i.,
g 631 PARK AVENUE hI E
sg s,
KING OF PRUSSI A, PENNSYLVANI A 19406 Docket No.70-371 NOV.h 193 United Nuclear Corporation Naval Products Division ATTN:
Mr. D. E. Ganley General Manager 67 Sandy Desert Road Uncasville, Connecticut 06382 Gentlemen:
Subject:
Inspection 70-371/78-19 This refers to the inspection conducted by Mr. I. Cohen of this office on November 7-9, 1978, of activities authorized by NRC License No. SNM-368 and to the discussions of our findings held by Mr. Cohen with Mr. T.
Collopy of your staff at the conclusion of the inspection.
Areas examined during this inspection are described in the Office of Inspection and Enforcement Inspection Report which is enclosed with this letter.
Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
Based on the results of this inspection, it appears that one of your activities was not conducted in full compliance with NRC requirements, as set forth in the Notice of Violation, enclosed herewith as Appendix A.
This item of noncompliance has been categorized into the levels as described in our correspondence to you dated December 31, 1974.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office, within twenty (20) days of your receipt of this notice, a written statement or explanation in reply including:
(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further items of noncompliance; and (3) the date when full ccmpliance will be achieved.
In accordance with the Atomic Energy Act of 1954, Restricted Data which requires safeguarding in the interest of national defense, shall not be disseminated or disclosed to unauthorized persons; therefore, the enclosures to this letter,and your response to this letter will not be placed in the Public Document Room and will receive limited distribution.
rl903090WO
United Nuclear Corporation 2
November 24, 1978 Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely,
),,. r -
/A Walter G. Martin, Chief Safeguards Branch
Enclosures:
1.
Appendix A, Hotice of Violation (Contains C-RD) 2.
Office of Inspection and Enforcement Inspection Report Number 70-371/78-19 (Contains C-RD & 2.790 Info)