Form NRC418 U.S. NUCLE AR REGULATORY COMMtSSION

( Y' CERTIFICATE OF COMPLIANCE 10 l R 71 For Radioactive Materials Packages 1.(a) Certi i a Number 1.(b) Revision No 1.(c) Package I nii i 1.(d) P es No. 1.(e) Tota No. Pages

2. PRE AM8LE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Pizardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.

r 2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country througn or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

U.S. Department of Energy Monsanto Research Corporation Albuquerque Operations Office Mound Laboratory P.O. Box 5400 Report No. MLM-2447 Albuquerque, NM 87115 gsp,9 Q Sg te g r 30, 1977 3,,,

4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a)

Packaging (1) Model No.: AL-M1 (2) Description Packaging for tritiated water held on sorbent material. The outer packaging is a 55-gallon drum with a vented lid. The drum body and lid are fabricated from 16-gauge steel.

The stainless steel valved cylindrical tank provides primary containment, and is held within a sealed stainless steel secondary container which has a 6-5/8-inch 0.D.

by 23-7/8-inch height.

The primary and secondary containers are centered within the drum by the drum lining and spacers made from Superex and Firedike insulation (Johns-Manville products).

The package gross weight is 550 pounds.

(3)

Drawings Packaging is fabricated in accordance with Monsanto Research Corporation, Mound Laboratory Drawings Nos. AYD-740425, Rev. C; AYD-760626, Rev. B; and AYE-740198, Rev. D.

79030900 6

=4 Page 2 - Certificate No. 9125 - Revision No. 0, Docket No. 71-9125 (b) Contents (1) Type and form of material Tritiated water completely sorbed on molecular sieve, silica gel or commercial clay within the containment vessel specified in 5(a)(3). The maximum quantity of organic contaminants shall not'

~

exceed 1% of the water content.

(2) Maximum quantity of material per package Tritium content of water shall not exceed 100,000 Ci (10g), and internal decay heat shall not exceed 3.3 watts.

The maximum quantity of water with corresponding minimum quantity of specified sorbent so that no free standing liquid is present during shipment is as follows:

Minimum Maximum Sorbent Material Sorbent (kg)

Water (g)

Molecular Sieves 4A, 5A or 13X 5.6 2000 Silica Gel 6.4 2000 Montmorillonite Clay Florco, Floridin Co.

4.2 2500 6.

Each containment vessel, prior to first use, shall be leak tested using helium. The test shall have sufficient sensitivity to detect a leak rate 1x10 6 cm3/sec of helium gas at standard temperature and pressure.

7.

The loaded package shall be tested for tritium leakage prior to shipment using an ionization monitoring technique. The test shall be sufficiently sensitive to detect a maximum tritium release corresponding to lx10 3 curies per hour.

8.

At the time of shipment the pressure in the primary containment vessel will not exceed 1 atm at ambient temperature.

9.

The packaging authorized by this Certificate of Compliance is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

10. Expiration date: January 31, 1984.

.4 Page 3 - Certificate No. 9125 - Revision No. O, Docket No. 71-9125 REFERENCE Monsanto Research Corporation, Mound Laboratory Report No. MLM-2447, September 30, 1977.

FOR THE U.S. NUCLEAR REGULATORY COMMISSI.0N

$Y fIL Y

Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety Date:

If " * - <c?o