ML19276H157

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 760728-30 & 0803-04
ML19276H157
Person / Time
Site: Crane  
Issue date: 09/15/1976
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML19276H153 List:
References
50-289-76-18, 50-320-76-10, NUDOCS 7910150185
Download: ML19276H157 (1)


Text

_.

1

)

APPENDIX A NOTICE OF VIOLATIONS Metropolitan Edison Company P. O. Box 542 Reading, Pennsylvania 19603 Docket No. 50-289 Based on the results of the NRC inspection conducted on July 28-30 and August 3 and 4, 1976, it appears that certain of you activities were not conducted in full compliance with NRC regulations and the conditions of your NRC Facility License No. DPR-50, as indicated below.

These items are categorized as Deficiencies.

I

~

2 A.

Section 5.5.1 of the Environmental Techncial Specifications (ETS) requires, in part, that written procedures be prepared to ensure compliance with various activities involved in carrying out the l

provisions cf the ETS.

One of these activities is the analyses of background and indicator station air samples for I-131 and radio-i active particulates.

Contrary to this requirement, written procedures have not been prepared to ensure compliance with the ETS with regard to the O

analysis of I-131 and radioactive particulates in air samples.

B.

Section 4.4.a of the ETS requires, in part, that quarterly gamma spectral analysis be performed on the composites of the eight weekly indicator air particulate sample stations and of the one weekly background air particulate sample station.

Contrary to this requirement, weekly air particulate samples were not composited as described above, for the quarterly background samples since 1974.

Other deficiencies identified through your internal cudit program and which were reported (if required) and corrected, or in which corrective l

action was initiated, are identified in the inspect 1on report.

No additional information is needed for these items at this time.

1413 071 b

7910150 / 8 b c

\\t a

._