/p.,J :t..w 104 Davey Laboratory Penn. State University University Park Pa.,
16802 19 August 1979 Director, Division of Site Safety and Environmental Analysis U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Gentlemen:
Enclosed are my comments on the Draft Environmental Statement for the Virgil C. Summer Nuclear Station, NUREG-0534. Please note that the Information presented is my own and not necessarily the position of The Pennsylvania State University, which affiliation is given for identification purposes only.
My comments consist of one page of inain text ( beyond this page) and ten pages of acpendix, which I would like to have considered in entirety.
Sincerely, Y
YbOb $[{Q
@ys,4 m" n m 7 9 08 2 8 07(/g
e.
The Long Term Health Consequences of Virgil C. Summer Nuclear Station by William A. Lochstet The Pennsylvania State University
- August 1979 The Nuclear Regulatory Commission has attempted to evaluate the heel th consequences of operation of the Virgil C. Summer Nuclear 8tation in its draft environmental statement NUREG - 0534. The following comments are directed twward assisting the NRC in fulfilling its obligation under the National Environmental Policy Act of 1969 (NEPA).
The health consecuences of radon - 222 emissions from the uranium fuel cycle are improcerly evaluated.
There is no justification for imposing any time limit on their accrual.
Rather, the entire toxic life of the wastes must be considered.
Such an evaluation has been performed and is attached to this statement as an appendix ( " Comments on NUREG-0332").
This evaluation is based on a model 1000 MWe LWR power plant.
This kind of evaluation is required by footnote 12 of NRDC v. USNRC, 567 F.2d 633 (1976).
The opinions and calculations presented here are my own, and not necessarily those of The Pennsylvania State University.
"y affiliation is given here for identification purposes only.
D * ') D} ' My 'b f(
y"
.o d Ju efd J,j o
20k$
\\
9 Comments on NUREG-0332 by Dr. William A. Lochstet The Pennsylvania State University November 1977 In the document NUREG-0332 (Draft), the NRC estimates the excess deaths per 0.8 gigawatt-year electric (GWy(e)) to be about 0.5 for an all nuclear eccnomy and about 15 to 120 for the use of coal (Ref.1). These estimates are much too small because they ignore the health effects due to the slow release of radon-222 resulting from the decay of radioactive components of the coal, uranium mill tailings, and of the tailings from the uranium enrichment process.
If the health effects are estimated by the procedure used by the NRC4 then the excess deaths are about 600,000 in the nuclear case and twentythousand for coal. The estimates presented here are all based on the production of 0.8 GWy(e).
Radon Produced by the Uranium Fuel Cycle The production of 0.8 GWy of electricity by a LWa will require about 29 metric tons of enriched uranium for fuel.
With uranium enrichnent clants operating with a 0.2% tails assay,146 metric tons of natural uranium will be reouired.
In the absence of the LMFBR,117 metric tons of depleted uranium would be left over. With a uranium mill which extracts 966 of 9 nm boNbbb k 204i 145
2 the uranium from the ore ( Ref. 2), a total of 90,000 metric tons of ore is mined, containing 152 metric tons of uranium.
The uranium mill tailings will contain 2.6 kilograms of thocium-230 and 6 metric tons of uraniug. As Pohl has pointed out (Ref.3 ) the thorium - '230 decays to radium - 226, which in turn decays to radon - 222. This process results in the generation 8
of 3.9x10 curies of radon-222, with tha time scale determined 4
by the 8x10 year half life of thorium - 230.
The 6 metric tons of uranium contained in the mill tailings decay by several steps to radon - 222 thru thorium - 230. This 9
process occurs on a time scale governed by the 4.5x10 year half life of uranium - 238, the major isotope present ( 99.3fd.
The total amount of radon - 222 which will result from this O
11 decay is 8.6x 10 curies.
The 117 metric tons of depleated uranium from the enrichment orocess is also mainly uranium - 238 which also decays.
The decay of these enrichment tailings results in a total of 13 1.7x10 curies of radon - 222. This is listed in Table 1, along with the other radon yields.
It is instructive to comrare these quantities of activity to the activity of the fission products which result from the use of the fuel which they are associated with. The total fission product inventory resulting from 0.80Ty(e) with half 7
lives of 25 years or more is about 10 curies. This is much less than any of the numbers in Table 1.
'cle should be more careful with these tailings.
'j ff f \\
\\ bt
3 Radon Produced by the Coal Fuel Cycle Ites 2 i of Appendix A of NUREG-0332 ( Ref.1) assumes a 75% cacacity factor, which for a 1000 Efe plant would produce only 0.75 GWy(e). A capacity factor of 80% will be used here.
The production of 0.8 GWy(e) by a coal plant operating at 40%
efficiency, using 12,000 BTU per pound coal would require 2.5 million short tons of coal.
This is close to the value of million tons suggested on page 9 of W REG-0332 ( Ref. 1).
There is great variability in the amount of uranium contained in coal. An analysis of coal samples at one T7A plant reported by the EPA ( Ref. 6) indicates a range of almost a factor of ten in uranium content.
Eisenbud and Petrow (Ref. 5) report a value of about 1 part per million.
A recent survey by the USGS based on several hundred samples suggests that in the United States coal contains an average of 1.8 part per million of uranium ( Ref. 6). Both values of 1.0 and 1.8 ppm will be used here.
Thus 2.5 million tons c f coal will contain thousand between 2.3 and 6.1 kilograms of uranium.
Using the assumption of NUREG-0332 (Ref.1) that there is 99% particulate removal from olant emissions, 1% of this uranium will be edispersed into the air and the remainder carted away as ashes for land burial. Table 1 indicates that with 1.0 ppm coal the uranium 11 in the resulting ash will decay to a total of 3.2x10 curies
]Gl\\ \\
\\
A 9
of radon - 222, while the stack emissions will lead to 3.2x10 curies. For 1.8 ppm coal the values are 5.8x10lleuries from ash 9
and 5.8x10 euries from emissions.
Evaluation of the Health Effects It is necessary to evaluate the number of deaths which result from the rele tse of one curie of radon - 222. For the purpose of this evaluation the population and population distributions are assumed to remain at the present values. This should provide a good first estimate.
NUREG-0332 (Ref. 1) suggests that a release of 4,800 curies of radon - 222 from the mines ( page 11) would result in 0.023 R
excess deaths ( Table la, page 18). This provides a ratio of 4.$x10-6 deatha per curie. Data from Chapter I7 of GESMO (Ref. 7) suggests a value of 1.7x10-0 deaths per curie as a lower limit.
The value of 4.8x10-6 deaths per curie will be used here as the NRC estimate. It is understood that this is very approximate.
The EPA has evaluated the health effects of a model uranium mill tailings pile. They estimate a total of 200 health effects (Ref. 8, page 73) for a pile which emits at most 20,000 curies of radon - 222 for 100 years.
The resulting estimate is 1.0x10-6 deaths per cati, and will be used here as the EPA estimate.
') () l\\ \\
\\ '1
5 Evaluation of Health Effects - Nuclear At present some recent uranium mill tailings piles have 2 feet of dirt covering. In this case the EPA estimate (Ref. 8) is that about 1/20 of the radon produced escapes into the air.
This factor of 20 is listed in iTable 1 and is used to find the 8
effective releases.
Thus the 3 9x10 curies of radon which results from thorium in the mill tailings results in a release of 1.9x107 curies into the atmosphere, which with the NRC estimate of L.8x10-6 deaths per curie results in 90 deaths.
it h the EPA estimate 1900 deaths result.
A similar treatment applied to ll 8.6x10 euries of radon from the uranium in the mill tailings results in 200,000 dead for the NRC estimate and L.3 million for the EPA estimate. It is here assumed that no future generation will see fit to take any better care of the mill tailings than is presently practiced.
The uranium enrichment tailings are presently located in the eastern cart of the country.
It is assumed that these are buried near their present locations. Radon will not escape so easily through wet soil. A reduction factor of 100 is used to estimate this effect. The accuracy of this estimate depends on the particulars of the burial which can only be projected. An' additional factor of 2 is used to reduce the effect due to the fact that much of this radon would decay over the ocean rather than populated n cd f )
hh0 c
6 land areas. No compensation is taken for the greater population density near the point of release as compared to the uranium mill tailings piles of the western states. 'Sith this total reduction factor of 200 the NRC estimate is A00,000 dead while the EPA value is 8 million.
Evaluation of Health -Effects -
Coal It is assumed that the ashes from the coal plants idll be buried in a manner similar to the tailings from the uranium enrichment process. Thus a reduction factor of 200 is used in this case also.
Again the higher population density is ignored.
The particulate which is released into the air by the coal plant is taken to contain 1% of the contained uranium.
Since most such plants are in the eastern cart of the country it is estimated that half will fall into the ocean rather than onto land. A second factor of 2 is used to reduce the effect of the resulting radon due to the fact that some of this radon will decay over ocean as with the radon from the uranium in the enrichment tailings. Again no compensation is taken for the greater population density near the point of release. This gives the total reduction factor of A shown in table 1.
With these reduction factors auplied to the radon released by the ashes and emissions, in the two cases of 1.0 ppm and 1.8 ppm uranium content coal, the health effects are calculated.
These are shown in Table 1, and range from 7,700 dea. from ashes and 3,800 additional dead from airborn emissions for 1.0 ppm coal in the NRC estimate to 290,000 dead from ashes and 140,000 dead from airborn releases in the case of 1.8 ppa coal in the EPA estimate.
20/,i i50
7 Discussion It is obviously very difficult to estimate with any crecision how many health effects result from the release of a given curie of radon - 222 from some specific site in the west. The estimates presented here differ by a factor of 20. This might best be used as a range of expected deaths. The reduction factors used here are crude estimates in some cases, and could be improved upon. Changes in publid policy could also change the manner in which this material is disposed, thus greatly changing these factors. In particular deep burial could practically eliminate the escape of radon to the atmosphere (Ref. 8).
It is important to compare Table 1 here with Table 1 of NUREG-0332 (Ref. 1), which shows 0.47 dead for the nuclear case and at most 120 dead for coal.
These last numbers totally ignore the effects of long term radon emissions, which result in at least 100 times higher mortality. These long term effects are not only significant, but dominate the effect.
It is important to use Table 1 to com' pare the relative risk of the nuclear and coal option in their present forms.
In this case deaths due to all causes considered in NUREG-0332 can be ignored as insignificant, since they are so small.
The absolute number of deaths ner curie relea sed is irrelevant since it enters in both cases. The relative risk is determined solely by the quantities of radon - 222 generated and the reduction factors. Unless there is a clear decision to treat e coal ashes differently from uranium enrichment tailings, the health effects from the tailings will be 50 times greater since there is 204i i51
8 50 times more uranium there. The nuclear option remains more hazardous than coal unless the releases from all of the tailings piles can be reduced below the releases from the airborr.
particulates of the coal plant. This is not the present policy.
Additional Comment There is a typographical error on page 25 of NUREG-0332.
Reference #33 is listed there as being in volume 148 of Science, whereas it appears in volume 144.
Acknowledgment The above comments were inspired by the 5 July 1977 testimony of Dr. Chauncey R. Kepford in the matter of the Three Mile Island Unit 2 (Docket No. 50-320) operating license entitled: " Health effects Comparison for Coal and Nuclear g
Power".
i 204i 152 I
i
9 Table 1
Energy Source Excess Mortality per 0.8 G?ly(e) d6e to Radon - 222 emissions Origin of Radon Reduction Deaths Deaths Radon Generated Factor NRC EPA Curies Nuclear Thorium in 8
3.9x10 20 90 1900 Mill Tails U#""i" i" ll 6
8.6x10 20 200,000 4.3x10 Mill Tails Uranium in 13 200 A00,000 8x100 Enrichment 1.7x10 Tails Coal 1.0 upm U 11 Ashes 3.2x10 200 7,700 1.6x105 9
b Air 3.2x10 4
3,800 8x10 Particulate Coal 1.8 ppm U 11 5
Ashes 5.8x10 200 14,000 2.9x10 Air o
5 5.8x10' A
6,800 1.4x10 Particulate E_0
10 References 1
" Health Effects Attributable to Coal and Nuclear Fuel Cycle Alternatives" NUREG-0332, Draft, U.S. Nuclear Regulatory Commission (September 1977) 2 "Znvironmental Analysis of The Uranium Fuel Cycle, Part I -
Fuel Supply" EPA-520/9-73-003-B, U.S. Environmental Protection Agency, (October 1973) 3 R.O. Pohl, " Health Effects of Radon - 222 from Uranium Mining" Search, 2( 5),3 A5-3 50 ( August 1976)
A P.F. Bedrosian, D.G. Easterly, and S.L. Cummings," Radiological Survey Arcund Power Plants Using Fossil Fuel EERL 71-3, U.S. Environmental Protection Agency, (July 1970) 5 M. Eisenbud, and H.G. Petrow," Radioactivity in the Atmospheric Effluents of Power Plants that Use Fossil Fuels," Science 14L,:288-289 (1964) 6 v.E. Swanson et al," Collection, Chemical Analysis, and Evaluation e
of Coal Samples in 1975", Open-file recort 76-L68, U.S.
Department of the Interior, Geological Survey, (1976) 7
" Final Generic Environmental Statement on the Use of Recycle Plutonium in Mixed Oxide Fuel in Light Water Cooled Reactors," NUREG-0002. U.S. Nuclear Regulatory Commission, (August 1976) 8 See Ref. 2 204i 154