Ack Receipt of 781227 & s Informing NRC of Steps Taken to Correct Deviations Noted in QA Program Insp Rept 99900286/78-02
ML19276E792
Person / Time
Issue date: 02/06/1979
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Bopp R
APV GAULIN, INC. (FORMERLY GAULIN CORP.)
Shared Package
ML19276E793 List:
References
REF-QA-99900286 NUDOCS 7903210094
Download: ML19276E792 (1)


Text

e

=

=

~~

t ** " E c UNITED STATES

}

oq[o

.s NUCLEAR REGULATORY COMMISSION O

g REGION IV

{ ;;, f 611 RYAN PLAZA DRIVE, SUITE 1000 o"-

AR LINGTCN, TEX AS 76011

'$$ ll,. #'

_0 6 FEB 1973 Docket flo. 99900286/78-02 Gaulin Corporation Attn: Mr. R. Bopp Manager, Quality Assurance 44 Garden Street Everett, MA 02149 Gentlenen:

Thank you for your letters of December 27, 1978, and January 23, 1979 in response to our letters of flovember 13, 1978 and January 11,1979 and discussion with you during a telephone call on January 8,1979.

We understand that qualificaticn of the Shielded Metal Arc Welding procedure has been performed in the postweld heat treated condition and the results were acceptable.

Further, Gaulin Corporation's sub-contractor has revised the Gas Metal Arc Welding procedure to reflect qualification in the postweld heat treated condition and that this is now a part of the records for the pump pedestals in question.

We have no further questions at this time and will review your corrective action during a future inspection.

Sincerely,

\\

r J

V Uldis Potapovs, Chief Vendor Inspection Branch 7 9 0 3 210 ff/Cf