Amend 50 to DPR-44 & Amend 50 to DPR-56 Incorporating Tech Specs Contained in Appendices a & B as Revised Re Estimated Chemical Usage
ML19276E645
Person / Time
Site: Peach Bottom  
Issue date: 02/26/1979
From: Ippolito T
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19276E646 List:
References
NUDOCS 7903200123
Download: ML19276E645 (8)


Text

UNITED STATES 9

-'k NUCLEAR REGULATORY COMMISSION WASHING TON, D. C. 20555 PHILADELPHIA ELECTRIC COMPANY PUBLIC SERVICE ELECTRIC AND GAS COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-277 PEACH BOTTOM ATOMIC POWER STATION, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 50 License No. OPR-44 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Philadelphia Electric Company, et al., (the licensee) dated January 23, 1979, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I;

^

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the heal th and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the healtn and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all aoplicable requirements have been sati sfied.

'7903200123

. 2.

Accccdingl-the license is amended by changes to the Technica' Specifications as indicated in tne attachment to this license amendment, and pa agraph 2.C(2) of Facility Operating License flo. OPR-44 is hereby amended to read as follows:

(2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amencment No. 50, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Soecifications.

3.

This license amendment is effective as of the date of its' issuance.

FOR THE NUCLEAR REGULATORY COMMISS:0N hC' Oc Thomas 174ppolito, Chief Operating Reactors Branch =3 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance:

Februa ry 26, 1979

ATTACHMENT TO LICENSE AMENDMENT NO. 50 FACILITY OPERATING LICENSE N0. DPR-44 DOCKET NO. 50-277 Replace the following page of the Appendix "B" Technical Specifications with the enclosed page.

The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 9

9

PBAPS TABLE 2. 2. 4-1 ESTIMATED CHEMICAL USAGE ESTIMATED USAGE ESTIMATED RELEASES CHEM ICAL (lbs/ year)

(lbs/ yea r)

REMARKS Boric Acid 6,000 0

Borax 6,000 0

Calcium 5,000 5,000 Release includes Hypochlorite chlorides I

Chlorine 500,000 500,000 Release Includes as CL2 chlorides I

Coagulant Aid 5,000 5,000 Liquid Alum 180,000 0

As received Solution - 50%

Soda Ash 5,000 0

Sewage Treatment Sodium 340,000 0

Demineralizer Hydroxide Regeneration and Clarifier pH Adjustment.

Sodium 6,000 6,000 Sewage Treatment.

Hypochlorite Release includes chlorides Sodium Nitrite 20,000 0

As received.

Solution - 50%

Sodium 2,000 2,000 Auxiliary Boilers Phosphate sodium 0

583,000 Product of Sulphate Demineralizer Regeneration and l

Clarifier Treatment.1 Sodium sulfite 1,000 100 Auxiliary Boilers Fulfuric Acid 400,000 0

Demineralizer Regeneration Unidentified 4,200 4,200 Laboratory Drains Chemical Wastes including Water.

Amendment No. 29, 50 4 r UNITED STATES ya.

?';

NUCLEAR REGULATORY COMMISSION j

WASHINGTON, D. C. 20665 PHILADELPHIA ELECTRIC COMPANY PUBLIC SERVICE ELECTRIC AND GAS C0f!PANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-278 PEACH BOTTOM ATOMIC POWER STATION, UNIT NO. 3 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 50 License No. DPR-56 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Philadelphia Electric Company, et al.,(the licensee) dated January 23, 1979, complies with the standards and requirements of the Atomic Energy Act of 1954, as amendcu (the Act) and the Commission's rules and regulations set f orth in 10 CFR Chapter I; B.

The facility will operate in conformity with the applicatic",

the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requiremerits have been sati sfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in tne attachment to tnis license amendment, and paragraph 2.C(2) of Facility Operating License No. DPR-56 is hereby amended to read as follows:

(2) Technical Soecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 50, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its. issuance.

FOR THE NUCLEAR REGULATORY ' COMMISSION

-~~~ A ThbmasA'./Iho'lito, Chief

/

Operating Reactors Branch =3 Division of Operating Reactors

Attachment:

Changes to the Technical Specifications Date of Issuance: February 26, 1979

ATTACHMENT TO LICENSE AMENDf1ENT NO. 50 FACILITY OPERATING LICENSE N0. DPR-56 DOCKET NO. 50-278 Replace the following page of the Appendix "B" Technical Specifications with the enclosed page. The revised page is idnetified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 9

9

PBAPS TABLE 2. 2. 4-1 ESTIMATED CHEMICAL USAGE ESTIMATED USAGE ESTIMATED RELEASES CHEMICAL (lbs/ year)

(lbs/ yea rl REMARKS Boric Acid 6,000 0

Borax 6,000 0

Calcium 5,000 5,000 Release includes Hypochlorite chlorides l

Chlorine 500,000 500,000 Release Includes as CL2 chlorides I

Coagulant Aid 5,000 5,000 Liquid Alum 180,000 0

As received solution - 50%

Soda Ash 5,000 0

Sewage Treatment Sodium 340,000 0

Demineralizer Hydroxide Regeneration and Clarifier pH Adjustment.

Sodium 6,000 6,000 Sewage Treatment.

Hypochlorite Release includes chlorides Sodium Nitrite 20,000 0

As received.

Solution - 50%

Sodium 2,000 2,000 Auxiliary Boilers Phosphate Sodium 0

583,000 Product of Sulphate Demineralizer Regeneration and Clarifier Treatment.

Sodium sulfite 1,000 100 Auxiliary Boilers Sulfuric Acid 400,000 0

Demineralizer Regeneration Unidentified 4,200 4,200 Laboratory Drains Chemical Wastes including Water.

Amendment No. zg, 50