RESOLUTION OF COMMENTS BY THE OFFICE OF NUCLEAR REACTOR REGULATION ON DRAFT SAFETY EVALUATION FOR TOPICAL REPORT ANP-10346P, REVISION 0, ATWS-I ANALYSIS METHODOLOGY FOR BWRs USING RAMONA5-FA FRAMATOME, INC.
PROJECT NO. 728/DOCKET NO. 99902041 This attachment provides the U.S. Nuclear Regulatory Commission (NRC) staffs review and disposition of the comments made by Framatome Inc. (Framatome) on the draft safety evaluation (SE) for Topical Report (TR) ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA. Framatome provided the comments by letter dated June 20, 2019 (Agencywide Documents Access and Management System Accession No. ML19175A122).
Change Page Line Comment Resolution Number Number Number/s
- 1. 24 16 Change more to less, less NRC staff agrees, conservative means lower PCTs and change has been incorporated as-is.
- 2. 29 26-27 Change ['''''' '''''''' ''''''''''' NRC staff agrees,
'''''''''' ' ''''''''''''''''''''''''''' '''''''''''' and change has
'''''''''''''''''' '''''''''''''''' '''''''''' been incorporated
'''''''''' '''' ''''''''''''''''''' as-is.
''''''''''''''''']. to ['''''' ''''''''''''''' '
'''''''''''''''''''''''' '''''''''].
- 3. 46 41 Add the unit of Hz to the NRC staff agrees, frequency acceptance criteria. and change has been incorporated as-is.
- 4. 15 35 A statement should be added at A paragraph was the end of Section 4.2.2.5 to added at the end of clarify and provide Section 4.2.2.5 to acknowledgement of the explicitly acceptance and approval with acknowledge the Cr-doped fuel, which was submission and described in Appendix A of the approval of RAI responses Appendix D to ANP-(ANP-10346Q1P). 10346P.
- 5. Throughout - Information that should be NRC staff agrees, marked as Proprietary is and change has highlighted in Yellow. been incorporated as-is.