ML19276E400
| ML19276E400 | |
| Person / Time | |
|---|---|
| Issue date: | 01/18/1979 |
| From: | Brown G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Moss J EMVTGR |
| Shared Package | |
| ML19276E396 | List: |
| References | |
| NUDOCS 7903120554 | |
| Download: ML19276E400 (2) | |
Text
,...
(J H ) f s
kn Mcg UNITED STATES o
NUCLEAR REGULATORY COMMISSION es n
REGION IV
{ f.'
611 RYAN PLAZA DRIVE, SUITE 1000 o,
AR LINGTON, TEX AS 76011 January 18, 1979 License No.
35-17178-01 Tulsa Gamma Ray, Inc.
ATTN:
James C. Moss President 5426 South 108th East Avenue Tulsa, Oklahoma 74145 Gentlemen:
This refers to the inspection conducted by Mr. C. L. Cain of this office on January 10, 1979, of the activities authorized by NRC Byproduct Material License No. 35-17178-01 and to the discussion of our findings held by Mr. Cain with you on January 10, 1979.
The inspection was an examination of the activities conducted under the license as they relate to radiation safety and to compliance with the Commission's rules and regulations, and the conditions of the license.
The inspection consisted of selective examinations of procedures and representative records, interviews of personnel, indepenaent measurements and observations by the inspector.
Mr. Cain also reviewed the action you had taken with respect to one item of noncompliance observed during our previous inspection, which was conducted August 25 and 30, 1977.
He verified that the corrective action with respect to this item was implemented as stated in your reply of September 27, 1977, to our letter dated September 13, 1977.
Based on the results of this inspection, it appears that one of your activities was not conducted in full compliance with NRC requirements, as set forth in the Notice of Violation, enclosed herewith. This item of noncompliance has been categorized into the level as described in the correspondence to you dated December 31, 1974.
This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.
Section 2.201 requires you to submit to this office, within 790312055[
Tulsa Gamma Ray, Inc. January 18, 1979 twenty (20) days of your receipt of this notice, a written statement or explanation in reply including:
(1) corrective actions which have been taken by you and the results achieved; (2) corrective actions which will be taken to avoid further items of noncompliance; and (3) the date when full compliance will be achieved.
Should you have any questions concerning this letter, please let me know.
Sincerely, 9
l
./
nl.4 rown, CH.,ie Fuel Facility and Material Safety Branch
Enclosure:
.