g.p a!cuq(o, UNITED OTATES g'
NUCLEAR RECULATORY CO.'.1MISS10N
[
' 1
{,k* g,.. rp/, _ $
REGION IV
%gl 611 RYAN PLAZA ORIVE, SUITE 1000
'gU4
/j ARLINGTON, TEXA3 76011 o
"v,,
O 11 OEC G78 Docket (40. 99900112/78-02 kaetek Corporation Calmec Division ATTN:
Mr. A. J. Ruddy General Manager 8401 East Slauson Avenue Pico Rivera, California 90660 Gentlemen:
Thank you for your letter of i'ovember 20, 1978, in response to our letter dated October 20, 1978. As a result of our review, we find that additional information, as discussed with your Mr. L. Ferguson during a telephone call on December 7, 1978, is needed.
Specifically, in response to f!otice of Deviation Item B.1, please provide a description of the method you will use to preclude recurrence of the failure of the Inspection Supervisor to pe*i-odically re-evaluate calibration cycles of equipment listed in Procedure CM-1005.
We have no further questions related to your response to Items A., B.2, and B.3 at this time. We will review your corrective and preventative actions on these items during a subsequent inspection.
Please provide this additiobal information within twenty (20) days in order that we may complete our review in a timely manner.
Sincerely,
?
3L c[ft : -cW v
Uldis Potapovs, Chief Vendor Inspection Branch 7903020/76