ML19275G528

From kanterella
Jump to navigation Jump to search
Discusses IE Insp of License 47-16182-01 on 800410 & Forwards Notice of Violation
ML19275G528
Person / Time
Issue date: 05/13/1980
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Mcdavid J
Union Boiler Co.
Shared Package
ML19275G523 List:
References
NUDOCS 8006120457
Download: ML19275G528 (2)


Text

'o UNITED 5TATES g

NUCLEAR REGULATORY COMMISSION o

g a

REGION il

,2 o

101 MAstlETTA ST., N.W sulTE 3100

..... p

ATLANTA, G EoRGIA 30303 In Reply Refer To:

W 13 M RII:RAB 47-16182-01 Union Boiler Company Huntington Testing Division Atta:

J. W. McDavid, President P. O. Box 1618 Huntington, W 25717 Gentlemen:

This refers to the inspection conducted by R. A. Brown of this office on April 10, 1980 of activities authorized by NRC License No. 47-16182-01, and to the discussion of our findings held with Mr. Yeoman at the conclusion of the inspection.

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Commission's rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection, it was found that certain activities under your license appear to be in noncompliance with NRC requirements. These items and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Appendix A.

This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regula-tions. Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:

(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter will be placed in the NRC's Public Document Room.

If this letter contains any information that you believe to be proprietary, it is necessary that you make a written application within 20 days to this office to withhold such information from public disclosure.

Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document. If we do not hear from you in this regard within the specified period, the letter will be placed in the Public Document Room.

8006120 C

,)

Union Boiler Company MAY 131980 Should you have any questions concerning this letter, we will be glad to discuss them with you.

Sincerely,

/

n

.' Philip ohr,C$iie7 Fuel Facility and Materials Safety Branch

Enclosure:

Appendix A, Notice of Violation a