VIRGINIA ELECTRIC ANI) POW 15 H CO M i% NY Rrennown, VIRGINIA 2006)
October 15, 1979 Mr. Harold R. Denton, Director Serial No. 804 Of fice of Nuclear Reactor Regulation LQA/WRM:pwc Attn:
Mr. A. Schwencer, Chief Operating Reactors Branch No. 1 Docket No. 50-338 Division of Operating Reactors U. S. Nuclear Regulatory Commission License No. F/F-4 Washington, D.C.
20555
Dear Mr. Denton:
AMENDMENT TO OPERATING LICENSE NO. NPF-4 NORTH ANNA POWER STATION UNIT NO. 1 PROPOSED TECHNICAL SPECIFICATION CHANGE NO. 20 Pursuant to 10CFR50.90, the Virginia Electric and Power Company requests an amendment, in the form of changes to the Technical Specifications, to Operating License No. NPF-4 for the North Anna Power Station Unit No. 1.
The proposed changes are enclosed and have been designated Change No. 20.
IE Bulletin 79-06A, item 13 requires the Licensee to no longer depend on pressurizer level for safety injection actuation coincident with low pressurizer pressure. As a result, actuation from only low pressurizer pressure using a (2/3) logic is proposed. Dependence on (2/3) low pressurizer pressure to actuate safety injection is conservative and consistent with other protective functions.
Increased reliability and testability for long term operation will result f rom using (2/3) low pressurizer pressure logic.
The coincidence arrangement of pressurizer pressure and level was originally designed to prevent false actuations of the SI system in the event of spurious pressurizer pressure on level signals. Removal of the level signal will eliminate all dependency on level for SI protection. Whenever system pressure is below 1765 psig, SI will be initiated regardless of the water volume present. This is a conservative way of insuring the core receives cooling.
Also included in this propos, i change is a specification change reducing the P-ll setting in the conservative direction in order to permit additional instrument reset tolerance.
Issuance of these specifications by the NRC should allow for installation and procedural changes; therefore, the license should indicate the specification to be effective following installation at the next cold shutdown condition.
1185 238 79101903925
Vruois:A ELECTRIC AND POWEB tOMPANY To Mr. Harold R. Denton 2-The enclosed changen have been reviewed and approved by rae Station Nuclear Safety and Operating Committee and the System Nuclear Safety and Operating Com-mittee. It has been determined that this request does not pose an unreviewed safety question.
We have evaluated the proposed Unit 1 Technict.1 Specification changes in accordance with the criteria in 10CFR170.22.
It has been determined that this request requires a Class III amendment fee.
Accordingly, you will find enclosed a voucher check in the amount of $4,000.00 in payment of the amendment fee.
Very truly yours, C. M. Stallings h
Vice President-Power Supply and Production Operations Attachments:
(1) Proposed Technical Specification Change No. 20 (2) Voucher Check No.38982 for $4,000.00 cc:
Mr. James P. O'Reilly, Director Of fice of Inspection and Enforcement Region II 1185 239
COMMONWEALTH OF VIRGINIA )
)
- s. s.
CITY OF RICHMOND
)
Before me, a Notary Public, in and for the City and Common-wealth aforesaid, today personally appeared W. L. Proffitt, who being duly sworn, made oath and said (1) that he is Senior Vice President, of the Virginia Electric and Power Company, (2) that he is duly authorized to execute and file the foregoing Amendment in behalf of that Company, and (3) that the statements in the Amendment are true to the best of his knowledge and belief.
Given under my hand and notarial seal this g day of D, f,),p s.
, ) 97).
My Commisslon explres i)gnvary 2/>.
/ e/ 9 /
kslv>l$ J8/ Notary Public (SEAL) 1185 240}}