ML19275A674

From kanterella
Jump to navigation Jump to search
Confirms 790912 Discussion W/Licensee Re Failure to Incorporate Instrument Root Valve Lineup in Facility Valve Lineup Control Procedures.Facility Will Suspend Power Escalation Until Lineup Has Been Accomplished
ML19275A674
Person / Time
Site: FitzPatrick 
Issue date: 09/13/1979
From: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
References
NUDOCS 7910180101
Download: ML19275A674 (1)


Text

n :c UNITED STATES kn Hoog o,

NUCLEAR REGULATORY COMMisslON

[

REGION I q

g 631 PARK AVENUE f

KING OF PRUSSI A. PENNSYLV ANI A 19406

%...../

Docket No. 50-333 SEP 13 7979 IAL No. 79-15 Power Authority of one State of New York James A. FitzPatrick Nuclear Power Plant ATTN: Mr. J. D. Leonard Resident Manager P. O. Box 41 Lycoming, New York 13093 Gentlemen:

This refers to the September 12, 1979 discussion between you and Mr. T.

Stetka of this office about the failure to incorporate instrument root valve lineup in the facility valve lineup control procedures as required by item 8 of IE Bulletin 79-08 prior to starting up the reactor plant.

3 With regard to the matters discussed, we understand that you have undertaken or will undertake the following actions:

1.

Suspend power escalation until the instrument root valve lineup has been accomplished and independently verified to be proper.

2.

Complete Plant Operations Review Committee review of the revised instrument valve lineup requirements on Sep'cember 13, 1979.

3.

Complete procedural revisions needed to incorporate instrument root valve lineups and issue the revised procedures by September 19, 1979.

4.

Conduct a specific review of the management control system which allowed this situation to occur, a1d make a written report of the results of that review to this office by September 27, 1979, with that report to place special emphasis upon the specific actions to be taken to prevent recurrence.

If our understanding of your planned actions, as described above, is not in accordance with the actual plans and actions being implemented,please contact this office by telephone and in writing within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Sincerely, s-Boyce H. Grier Director 1184 352 7910180/o/

Power Authority of the State of 2

SEP 13 gg73 New York cc:

George T. Berry, Executive Director P. W. Lyon, Manager - Nuclear Operations A. Klausmann, Director, Quality Assurance M... Cosgrove, Quality Assurance Supervisor J. F. Davis, Chairman, Safety Review Committee V. J. Cassan, Assistant General Counsel G. M. Wilverding, Licensing Supervisor 0

. - -