Text
.
Carolina Power & Light Company b
'.E August 1, 1979
'h FILE: NG-3513 (B)
SERIAL: GD-79-1967 m
.3 p
Mr. James P. O'Reilly, Director c.o U.S. Nuclear Regulatory Commission Region II rc 101 Marietta Street, Suite 3100 C
Atlanta, Georgia 30303 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1&2 LICENSE NOS. DPR-71 AND DPR-62 DOCKET NOS. 50-325 AND 50-324 SUPPLEMENT TO RESPONSE TO IE INSPECTION REPORT 324-325/79-02
Dear Mr. O'Reilly:
In our letter addressing IE Inspection Report 324-325/79-02, we committed to respond to Item 324-325/79-02-34 by August 1, 1979.
Carolina Power & Light Company submits the following response to that item:
United Engineers & Constructors (UE&C) was requested to review all plant modifications to determine which were safety related and to establish a schedule for drawing update.
Enclosed is a listing of plant modifications requiring a change in either frequently or infrequently used safety-related prints. All completed plant modifications will have their associated prints revised by September 14, 1979. All incomplete plant modifications will have their associated prints revised in a timely manner upon notification of their completion.
Your
.y truly, fY H. R. Banks Manager Nuclear Generation RMP: CSB: dej*
1095.'3 7910040 3 7 0
,_.,,._.s,,..,._,,,,._.-
,,339 D.E_ MAL coPr.
O e
G g
e ENCLOSURE 1 COMPLETED PLANT MODIFICATIONS NUMBER OF DR/. WINGS75-616 5
75-627 10 76-148 9
76-321 4
77-093 12
'77-094 21 77-203 5
77-256 84 77-315 10 77-369 163 77-370 451 77-372 7
78-022 28 78-023 6
78-078 7
78-268 52 78-269 57 INCOMPLETE PLANT MODIFICATIONS NUMBER OF DRAWINGS76-324 (ECP-5089) 208 77-027 (ECP-5075) 17 77-150 (FECP-9304) 47 77-204 5
77-255 80 77-327 62 1095.'?
.