4 e
[pn alcq, %
UNITED STATES 8
- k NUCLEAR nEGULATORY COMMisslON
.,,4
-[
W AS't1N G TO N, D.
C.
20555 f
S#
.F s
APR 0 61979 FCTR:Rii0 71-9096 Those on Attached List Gentlemen:
Enclosed is Certificate of Compliance No. 9096, Revision No. 2, for the Model No. CNSI-21-300 shipping package. This certificate supercedes in its entirety Certificate of Compliance No. 9096, Revision No.1, dated July 5, 1978.
Changes made to the enclosed certificate are indicated by vertical lines in the margin.
Those on the attached list have been registered as users of this package under the general license provisions of 10 CFR 571.12(b) or 49 CFR 5173.393a.
This approval constitutes authority to use this package for shipment of radioactive material and for the package to be shipped in accordance with the provisions of 49 CFR 5173.393a.
Sincerely.
gz,)' flE f
l s a c.v s t.
Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety
Enclosure:
As stated cc: w/enci Mr. Richard R. Rawl Department of Transportation 7904280l'l3
Model No. CNSI-21-300 USA /9096/A APR 0 S 1979 Addressees: w/ encl Alabama Power Company Georgia Power Company ATTN: Fir. F. L. Clayton, Jr.
ATTN: Mr. Max ilanry P.O. Box 2641 -
P.O. Box 442 Birmingham, AL 35291 Baxley, GA 31513 Carolina Power & Light Company Jersey Central Power & Light Company ATTl4: Mr. E. E. Utley ATTN: Mr. Ivan R. Finfrock, Jr.
P.O. Box 1551 Madison Avenue at Punch Bowl Road Raleigh, NC 27602 Morristown, ilJ 07960 Chem-Nuclear Systems, Inc.
Metropolitan Edison Company ATTN: Mr. Louis E. Reynolds ATTN: Mr. M. R. Buring P.O. Box 1866 P.O. Box 542 Bellevue, WA 98009 Reading, PA 19603 Consolidated Edison Company Niagara ilohawk Power Corporation of New York ATTN: ifr. Donald P. Dise ATTil: Mr. Stanley Wisla 300 Erie Boulevard West Broadway and Bleakley Avenue Syracuse, NY 13202 Buchanan, NY 10511 Northeast Nuclear Energy Company Duke Power Company ATTN: Mr. John Opeka ATTN; Mr. W. O. Parker, Jr.
P.O. Box 128 422 South Church Street Waterford, CT 06385 Charlotte, NC 28242 Power Authority of State of New York Florida Power & Light Company ATTil: ilr. J. D. Leonard, Jr.
ATTN: Mr. C. M. Wethy P.O. Box 41 P.O. Box 128 Lycoming, NY 13093 Ft. Pierce, FL 33450 Public Service Electric and Gas Company Florida Power & Light Company ATTN:
Mr. H. J. Midura ATTN: dr. Robert E. Uhrig P.O. Box 168 P.O. Box 529100 Hancocks Bridge, NJ 08038 Miami, FL 33152 Virginia Electric and Power Company Florida Power Corporation ATTN: Mr. W. L. Proffitt ATTil: Mr. J. T. Rodgers P.O. Box 26666 P.O. Box 14042 Richmond, VA 23261 St. Petersburg, FL 33733 s
t
)
1 4
Form NRC-G13 U.S. NUCLEAR REGULATORY COMM!SSION t 2 73)
CERTIFICATE OF COMPLI ANCE
,g pg For Radioactive Materials Packages
- 1. ( a ) Certificate Number 1.lb) Revision No.
1.lc) Package Identification No.
1.(d ) Pages No. 1.te) Total No. Pages 9096 2
USA /9096/A 1
2
- 2. PRE AM8LE 2.(a)
This certificate is issued to satisfy Sections 173.393a.173.394.173.395, ard 173.396 of the Department of Transportation Hazardot.s
- Aaterials Rejulations (49 CFR 170-139 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Danserous Cargoes Regulations (46 CF R 146-149), as ame=ed.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.'
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Cepartment of Transportation or other applicable regulatory agencies, including the government of an" country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package des!qn or applicatL w 3.(a)
Prepared by iName and address):
3.(b)
Title and identification of report or application:
Chem-fluclear Systems, Inc.
Chem-fluclear Systems, Inc. application P.O. Box 1866 dated August 2, 1977, as supplemented.
Bellevue, WA 98009 3.cc3 coc,,' No-71-9096 4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number, FissJe Class. Other Conditions. and
References:
(a) Packaging (1) Model flo. : CilSI-21-300 (2) Description A steel encased lead shielded cask for low specific activity radioactive material. The cask is a right circular cylinder with 86-3/4-inch OD by ll7-1/4-inch height, and a cavity 83-inch ID by 109-1/4-inch height.
The 1-inch thick lead shield is supported by outer and inner stainless steel shells 3/4-inch and 1/8-inch thick.
The inner plates of the lid and base are laminated steel plates with a total thickness of 1/2-inch.
Positive closure of the neoprene sealed lid is provided by twelve, 1-1/4-inch diameter cap screws. A secondary lid with a neoprene seal uses eighteen, 3/4-inch diameter bolts for closure.
The cask is welded to a 96-inch square base plate and has two lifting tr
,1 ions, three lid lift rings and one secondary lid lift ring. Package gross weight is 57,450 pounds.
(3) Drawing The packaging is fabricated in accordance with Chem-fluclear Systems, Inc. Drawing flo. 1-298-101, Rev. H.
{
a Page 2 - Certificate flo. 9096 - Revision No. 2 - Docket flo. 71-9096 5.
(Continued)
(b) Contents (1) Type and form of material (i) Process solids, either dewatered, sol.id or solidified in secondary containers, meeting the requirements for low specific activity radioactive material, or (ii) Solid reactor components in secondary containers, as required that meet the requirements for low specific activity radio-active material.
(2) Maximum quantity of rraterial per package Greater than Type A quantities of radioactive material with the weight of the contents, secondary containers and shoring not exceeding 27,250 pounds.
6.
Shoring shall be placed between secondary containers (or activated components) and the cask cavity to prevent movement during normal conditions of transport.
7.
The lid lif ting lugs shall not be used for lifting the cask and shall be covered in transit.
8.
The package authorized by this certificate shall be transported on a motor vehicle, railroad car, aircraft, inland water craf t, or hold or deck of a seagoing vessel assigned for sole use of the licensee.
9.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
10.
Expiration date: April 30,1983 REFERENCES Chem-Nuclear Systems, Inc. application dated August 2, 1977.
Supplement dated:
May 18, 1978; and January 23, 1979.
l Nuclear Packaging, Inc., supplements dated: March 10 and April 3,1978.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION bh v
i Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety APR 0 61979 Date: