ML19274D933
| ML19274D933 | |
| Person / Time | |
|---|---|
| Site: | North Anna |
| Issue date: | 02/22/1979 |
| From: | Stallings C VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| To: | Parr O Office of Nuclear Reactor Regulation |
| References | |
| 082, 82, NUDOCS 7902270248 | |
| Download: ML19274D933 (2) | |
Text
d VIItGINIA E LecrItIc ann Powelt COMPANY I{ ICII M O N D. VI H OI NI A 2 0 o 61 February 22, 1979 Mr. Harold R. Denton, Director Serial No. 082 Office of Nuclear Reactor Regulation LQA/RMN:esh Attn:
Mr. O. D. Parr, Chief Light Water Reactors Branch No. 3 Docket Nos.
50-338 Division of Project Management 50-339 U. S. Nuclear Regulatory Commission License No.
NPF-4 Washington, DC 20555
Dear Mr. Denton:
Our letter of May 1,1978 contained a minor typographical error in the attached " Summary of Proposed Modifications to the Spent Fuel Storage Pool Associated with increasing Storage Japacity." This error has been dis-cussed with members of the NRC Staff by phone and does not alter any conclu-sions in the Safety Evaluation Report.
Substitution of the attached page will correct the error. The change is indicated by a vertical line in the margin.
Very truly yours,
.~
[: j')'). \\}f' th-a C. M. Stallings Vice President-Power Supply and Production Operations Attachment cc:
Mr. James P. O'Reilly, Di rector Office of Inspection and Enforcement Region Il
\\
79022702Y P, h
4 TABLE 7-2 k
IIMAT LOAD COMPARISON IIcat Load,14 btu /IIr Present System Uith Modification (1500 Assemblies)
(966 Assemblies)
Fuel 1001 Cooling Systent Design Duty Normal Case 13.8 1 9. 11 Abnormal Case 33.2 35.9' Component Cooling Water System Design Duty (1)
Normal Operation (2P-211XR) 103.1 108.7 Abnormal Operation l
(l&P-11HXR)
(2) f102.1 407.6 Service Water System Design Duty (1)
(.,
Normal Operation (2 Pumps) 103.1 108.7 Abnormal Operation
( 11 Pumps)
(2) 1402.1 407.6 Total Heat Discharged to the Environment (1) 13,713 13,719 Normal Operation NOTES:
1.
Total for both units 2.
Maximum abnormal oberating duty for the component cooling water system and the service water system occurs during simultaneous fast cooldown of both reactor units.
This does not occur concurrent with the maximum abnormal fuel pool beat load which is the off loading of one full core starting 150 nr after shutdown.
(
51