T Tic I

  1. ""C%,

UNITED STATES

.,i NUCLEAR REGULATORY COMMISSION f.,y{S[

l REGION lli

,,.j t>j 7eenoosev.L1eo.o GLEN E LLYN. ILLINotS 60137

,.3, NAY 7 1979 Docket No. 50-341 The betroit Edison Company ATTN:

Mr. Edward Hines, Assistant Vice President and Manager Quality Assurance 2000 Second Avenue Detroit, MI 48226 Gentlemen:

This IS Information Notice No. 79-11 is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible appli-cability to their facilities.

No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding this matt <, please contact the Director of this office.

Sincerely, W E3 l b p-f -IW

[/ Janes G. Keppler Director

Enclosure:

IE Information Notice No. 79-11 cc w/ encl:

Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC 2350 181 Ronald Callen, Michigan Public Service Commission Eugene B. Thoma ;, Jr.,

Attorney 7906120lb