%OR50,Yo "O C00 00c00 Florida Power w e srewanr.o'necrOn POWER PRODUCTION c.oaeoa t n~
J..nua ry 24, 1979 Mr. Chris C. Nelson, Project Manager Operating Reactors Branch No. 4 office of Nuclear Reactor Regulation U.S.
Nuclear Regulatory Commission Washington, D.C. 20555
Dear Mr. Nelson:
Enclosed is a magnetic computer tape that contains the meteorology data at the Crystal River Site for 1975, 1977 and 1978 in the standard format re-quested in Mr. D.B. Vassallo's letter dated April 22, 1977.
A copy of the job control language is included for your reference.
The X/Q's for 1975 and 1977 that are enclosed were calculated by the X0QD0Q program using the site specific parameters from our Appendix 1 report of June, 1976.
The 1978 X/Q's will be forwarded as soon as possible.
All X/Q's are the non decay, undepleted X/Q's.
If you have any questions, please do not hesitate to contact this of fice.
Very truly yours, FLORIDA POWER CORPORATION
\\
kG^
(
W.
P. Stewart File:
3-0-20 ECSekcM01 (1/22D6) 790201o/w, General Office 3201 Thirty.tourtn street sou:n. P O Box 14042, st. Petersburg. Fionda 33733 e 813-8E6-5151
STATE OF FLORIDA COUNTY OF PINELLAS W.P. Stewart states that he is the Director, Power Production, of Florida Power Corporation; that he is authorized on the part of said company to sign and file with the Nuclear Regulatory Commission the information att.ched hereto; and that all such statements made and matters set forth therein are true and correct to the best of his knowledge, information and belief.
)-
b (_()((U I
W.P.* Stewart Subscribed and sworn to before me, a Notary Public in and for the State and County above name d, this 24th day of January, 1979.
t
/[
/
L Notary Publf.c Notary Public, State of Florida at Large, My Commission Expires:
July 25, 1980
l.
/ /
AI. et '.' t 'T J'.P
( I:1/, L )
H. \\L.f I f 'Ji, C L A S 3 s T, P I J,1 ("I r l v / $.
i
- it h 68 A R A1 i'"I
'13 2
//:ilP1 f 8 L P,4: 1 F t f;E *JE K t
1
/ / % Y d P K [fJT-l')
(. y ;,i n t i - A 4
/ / 5 Y F l '1
'l 5 0i ' 1'1%
/ / f YSilT 1 Ua ef tM T /13P S.ae10.M c T 75.D A T A,ijl P -( LL u, KE E P )
6
/ / S Y Sij i 2 00 U5f a -r 4 3. d L T 7 5.D A T A e t)C R= ( P LL F '4-F ii, L R EC Lr 1/,0, AL K S I Z L= 32 00,
//
DHJ-1 ),Uf 41'-T A P E, VUL -Si R -C R 3 ME T, L Ailt L' ( 1, S L ),0 ! S P '( NE W, P AS S )
/
/ / :3 ' L 6' /
E V F t.
P i r [ E d u E *!L 't
>l
/ /! YS PF [t;T' P') " v' ntIT r A 0
//5YSI'l DO OllUY 10
//SYSU]1 fjD O bn -lji 213R S.le kt.M E I / 7.G AT A, DI SP-(llL O, KL FP )
1L
//SYstlT2
- 9) D SrJ -LR 3. t E T / 7.0 A T A,9C B-( R EL FM-f 4, L P.FC I
- 16 0, TL K ? l l ts 32 00,
//
OF'l 3 ),N I T-T AP L, VUL = L ER cC u 3:tE T, L AH F L = (2, S L ),013 P r ( r4L W, P AS S )
1.
/ / 3 ' t~ P 3 EVEr P i" - I F B GE'lE R 13
/ / S Y : P s ! Pl' l.')
~. Y f ' ) t f T r a l ',
/ / 5 Y R l 's t?U Ol'11Y 15
/ / S Y Silt 1 l') D S tat 1* 213 R S. NRt..M E T 70. 0 A T 4, O ' S P '((JL O, KF F P )
16
//3YSUT2 D D D S t. = C R 3. M E T 7 6. D A T A, 0C B = ( R E C F M = F 1, L H E C L r l ') O, a l K S I /. L *- 3 2 O O,
//
Of *J - 3 ),ilt. I T r T AP E VfiL =S E R rC R 3 ?iE T, L Adi l '( 3,511, U I S P' ( Nt h, KI-t P I 9
AUXILLARY AND 4 E ACTOR BJILDINGS R ELEASE F olt4T NO UECAf, Uf4 DEPLETED
(,ft yST A L 02 g 2 SM CORRECTEC fan UPEN TERRAIN RECIRCULATION My7
( ANNUAL AVERAGE CHI /Q (SEC/ METER CUBEDI DISTANCE IN MILES SECTOR 0.250 0.500 0.750 1.300 1.500 2.000 2.500 3.000 3.500 4.000 4.500 g
i 5
5 7.601E-06 2.269E-06 1.149E-06 5. 752 E-07 2.295E-0 7 1.288 F-07 8.430E-09 6.0 35E-08 4. 587E-08 3.641E-08 2.984E-08 N
C SSW 3.522E-05 1.0 79E -0 5 5. 601E-06 2. 86] E-0 6 1 160E-06 6.434E-07 4.160E-0 7 2.949E-0 7 2.223E-07 1.752 E-07 1.427E-07 h
d SW 4.008E-05 1.222E-0 5 6.271E-Oo 3.169E-06 1. 273E-06 7 069E-07 4.582E-07 3.254E-07 2. 458E-07 1 940E-07 1 582E-07 l;
bt WSW 8.766E-05 2.666E-0 5 1.379E-05 6.984E-06 2.812E-06 1.561E-06 1.011E-06 7.175 E-07 5.416E-0 7 4.27 2E-07 3. 483E-07
[?]
W 1.272E-04 3.822E-0 5 1.937E-05 9.879E-06 4.017E-06 2. 24 3 E-06 1.458E-06 1.0 38E-06 7. 85 7E-07 6.211E-07 5.072E-07 K
WNW 3.935E-05 2. 701E-05 1.381E-05 7.079E-06 2. 891E-06 1.611E-06 1.046E-06 7.430E-07 5.614E-0 7 4.431E-07 3.615E-0 7
[)
4 i
NW
- 5. 6 54 E-0 5 1 726E-05 8.902E-06 4.599E-06 1.890E-06 1.049E-06 6.774E-07 4.796E-07 3.613E-07 2.844E-07 2.315E-07 h
NNW 3.456E-05 1.074E-0 5 5.689E-06 2.934E-06 1.198E-06 6.585E-07 4.220E-07 2.969E-07 2.224E-0 7 1.743E-07 1.4;3E-07
?
i,;
N 1.903 E-05 6.110E-06 3. 306E-06 1. 688 E-06 6. 77 8E-07 3.681E-07 2. 3 37E-07 1.632E-07 1.216E-07 9.481E-08 7.652E-08 di M
NNE 1 918E-05 6. 022E-06 3.155E-06 1. 606E-06 6. 45 7E-07 3. 52 SE-07 2.250E-07 1. 5 78E-07 1.179E-07 9.223E-08 7.464E-08 d
p NE 2.321E-05 7.409E-0 6 3.984E-06 2.007E-06 7. 96 7E-0 7 4.30 7E-0 7 2. 728E-07 1.902 E-0 7 1. 415E-07 1.102E-07 8.8 86E-08 h
ENE 3.230E-05 9.971E-0 6 5.265E-06 2.658 E-06 1 062E-06 5.737E-07 3.629E-07 2.528E-07 1 879E-07 1. 463E-07 1.179E -0 7 di
[d
(
E 3.442E-05 1.056E-0 5 5.680E-06 2.903E-06 1.176E-06 6.385E-0 7 4.049E-07 2.826E-07 2.103E-07 1.639E-07 1.323E-07 O
h tSE 3.10$E-05 9. 803E-0 6 5.2 85E-06 2.697 E-06 1.08 8E-06 5. 690 E-0 7 3.729E-07 2. 599 E-0 7 1.932E-07 1. 50 4E-07 1.212E-07
- t,t M]
SE 2.253E-05 7.218E-06 3.8 T9E-06 1.987E-06 8.013E-0 7 4.363 E-07 2.7 75E-07 1.9 41E-0 7 1. 447E-0 7 1.130E-07 9.12 5E-0 8
(__
SSE 1.137E-05 3. 58 7E -06 1. 893E-06 9. 712 E-0 7 3. 93 8E-0 7 2.15 7 E-07 1.379E-07 9.687E-08 7. 24 8E-0 8 5.674E-08 4.595E-0 8 r
"i A
Lo k AW4UAL AVE MGE CHI /O (SEC/ METER CUBED)
DISTANCE IN MILES N
BEARING 5.000 7.500 10.000 15.000 20.000 25.000~
30.000 35.000 40.000 45.000 50.000 W
- q n
u S
- 2. 50 7E-08 1.362E-0 8 9.163E-09 5.528E-09 3.872E-09 2.941E-09 2.3 52E-09 1.948E-09 1. 65 5E-09 1. 43 4E-09 1. 2 62E-09 O
SSW 1.192 E-0 7 6.346E-08 4.210E-08 2.491E-0 8 1.721E-08 1.294E-08 1.0 2 7E-08 8.444E-0 9 7.133E-09 6.149E-09 5.386E-09
~~ I m
SW 1.324E-07 7.080E-08 4.715E-08 2. 805E-0 8 1. 94 7E-08 1.469E-08 1.168E-08 9.629 E-09 8.151E-09 7.040E-09 6.177E-09 M
d WSW 2.913E-07
- 1. 556E-07 1.035E-0 7 6.151E-08 4. 264E-08 3.215E-08 2.555E-08 2.105E-08 1.781E-08 1.537E-08 1.348E-08 C
<=
W 4.249E-07 2.282E-07 1.523E-07 9.086E-08 6.316E-08 4.771E-08 3.797E-08 3.13?E-08 2.653E-08 2.292E-08 2.012E-08
' i t p kNW 3.025E-07 1.618E-07 1 077E-07 6.397E-08 4.433E-08 3.341E-08 2.654E-08 2.166E-08 1.848E-08 1. 59 5E -08 1. 3 98E -0 8 4
NW 1.933E-07 1.025E-0 7 6.785E-08 4.003E-0 8 2. 758E-08 2.070E-08 1. 6 38 E -08 1.346E-08 1.135E-08 9. 7 74E-09 8. 552E-09 y
NNW 1.176E-07 6.164E-08 4.045E-08 2.358E-08 1.613E-08 1.203E-08 9.477E-09 7.752E-09 6. 518E-09 5. 595E-09 44 882E-09 N
6.344E-08 3.280E-08 2.133E-08 1.228E-08 8.330E-09 6.176E-09 4.842E-09 3.945E-09 3.30tE-09 2.829E-09 2.463E-09 Id1 t
y id E
- 6. 23 5E-0 8 3. 241E-0 8 2.123E-08 1.235E-0 8 8. 45 0E-09 6. 305E-09 4.9 70E-09 4.0 67E-09 3.421E-09 2.73 8E-09 2. 566E -09 p
NE 7.364E-08 3.804E-08 2.4 ?3E-08 1.424E-08 9.676E-09 7.183E-09 5.639E-09 4.599E-09 3.858E-09 3. 306E-09 2.880E-09 e
i P ENE 9.772E-08 5.044E-08 3.2 78E-08 1.893E-08 1.286E-08 9.566E-09 7.520E-09 6.141E-09 5.157E-09 4.423E-09 3.857E-09 m
E 1.096E-07 5.663E-0 8 3.681E-08 2.119 E-0 8 1. 438E-08 1.066E-08 8.365E-09 6.818E-09 5.714E-09 4.893E-09 4.260E-09 C
M]
ESE 1.3045-07 5.167E-08 3.350E-08 1.922E-08 1.301E-08 9.631E-09 7.542E-09 6.139E-09 5.139E-09 4.396E-09 3.823E-09 L
h SE 7.571E-08 3. 923E -0 8 2. 555E-08 1.474E-08 1.001E-08 7.429E-09 5.829E-09 4. 7 52 E-09 3. 98 4E-09 3. 411E-09 2. 9 70E-0 9 bj
(
1 SSE 3.821E-08 1.995E-08 1.307E-08 7. 596E-0 9 5.190E-09 3.869 E-09 3.046E-09 2.491E-09 2.094E-09 1. 797E-09 1. 568E-09 U
h h*
t pjcHl/0 ( SEC /ME TER CU8ED) FCR E AC H SEGMENT SEGMENT BOUNDARIES IN MILES
'Q y
. 5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40
'40-50 q DIRECTION
( h FROM SITE J
M S
1.143E-06 2.616E-07
W SSW 5.535E-06 1.306E-06
- 4. 282 E-0 7 2.251E-07 1.436E-07 6.636E-08 2.531E-08 1.301E-08 8.465E-09 6.158E-09
^
t SW 6.214E-06 1.443E-06 4.714E-07 2.438E-07 1.592E-07 7.397E-08 2.848E-08 1.476E-08 9.652E-09 7.049E-09 h
hsW 1.362E-05 3.183E-06 1 040E-06 5.483E-07 3.506E-07 1.626E-07 6.247E-08 3.231E-08 2.110E-08 1.540E-08 h
H W
1.934E-05 4.531E-06 1.500E-06 7.952E-07 5.105E-07 2.382E-07 9.220E-08 4.794E-08 3.140E-08 2.295E-08 H
nNW 1.375E-05
- 3. 2 53F-06 1.075E-06 5.682E-07 3.638E-07 1.690E-07 6.495E-08 3.357E-08 2.191E-08 1.597E-08 F
[v NW 8 846E-06 2.118E-06 6.973E-07 3.658E-07 2.330E-07 1.073E-07 4.067E-08 2.081E-08
- 1. 3 49 E -0 8 9.789E-09 N
NNW 5.58FE-Oo 1.344E-06
- 4. 3 50E-0 7 2.254E-07 1.423E-07 6.467E-08 2.402E-08 1.210E-08 7.775E-09 5.604E-09 e
N 3.210E-06
- 7. 64 7E -0 7 2.414E-07 1.233E-07 7.709E-08 3 451E-08 1.253E-08 6.217E-09 3.958E-09 2.835E-09 a
s h NNE 3.104E-06 7.288E-07
- 2. 321 E -0 7 1.195E-07 7.519E-08 3.403E-08 1.259E-08 6.343E-09 4.079E-09 2.943E-09 W
NE 3.867E-06 9.334E-07 2.819E-07 1.435E-07 8.954E-08 4.003E-08 1.454E-08 7.230E-09 4.614E-09 3.312E-09 O
,M
.ENE 5.152E-06 1.200E-06 3.751E-07 1.906E-07 1.189E-07 5.310E-08 1.930E-08 9.627E-09 6.160E-09 4.431E-09
- v C
- 5. 5 TK - 0 6 1.321E-06 4.183E-07 2.133E-07 1.333E-07 5.960F-08 2.163E-08 1.074E-08 6.839E-09 4.902E-09 ESE 5.14 ) E-0 6 1.224E-06 3.853E-07 1.959E-07 1.221E-07 5.442E-08 1.963E-08 9.696E-09 6.159E-09 4.405E-09 SE 3.180E-06 9.025E-07
- 2. 86 5E-0 7 1.467E-07 9.193E-08 4.126E-08 1.504E-08 7.477E-09 4.767E-09 3.417E-09 SSE 1.860E-06 4.430E-07
- 1. 4 2 3E-0 7 7.345E-08 4.628E-08 2.095E-Oe 7.742E-09 3.892E-09 2.498E-09 1.800E-09
AUXILIARY AND RE ACTOR BJIL DINGS RELE ASE POINT NO DECAY, UNDEPLETED C RT5TAL RIVEf SITE l
CCRRECTED FOR UPEN TERRAIN RECIRCULATION p3 7 g-i ANNUAL AVilAGE LHl/0 ISEC/ METER CUBEDI DISTANCE IN HILES SECTOR 0.250 0.500 0.750 1 000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 5
3.09 5E-05 9. 550E-06 4.9 71E-06 2.543E-06 1.032E-06 5.697E-07 3.668E-07 2.591E-07 1. 94 8 F -0 7 1. 531 E-07 1. 2 44E -0 7 i
SSh 2.793E-05 8.450E-06 4.315E-06 2.193E-06 S.875E-07 4.941E-07 3.207E-07 2.280E-07 1. 72 3 E -0 7 1. 3 61 E -07 1.110E-07 SW 4.354E-05 1.3 35E-0 5 6.907E-06 3. 520 E-06 1. 42 4 E-06 7.873E-07 5.0 76E-07 3. 590E- 07 2 702E-07 2.126E-07 1. 729E-07
)
WSW 6.414E-05 1.935E-0 5 9.902E-06 5.063E-06 2.063E-Oo 1.148E-06 7.442E-07 5.2 86E-07 3.992E-0 7 3.150E-07 2. 569E-07 W
7.758E-05 2.3 28E-05 1.184E-05 6.055 E-06 2. 4 71 E-06 1.379E-06 8.961E-07 6.3 76E-07 4.822E-07 3 810E-07 3.110E-0 7 WNW 4.29dE-05 1. 306E -0 5 6. 716E -06 3.438E-06 1.400E-06 7. 7 7 7E-0 7 5.034E-0 7 3 5 72E-07 2.69 5E-0 7 2.125E-07 1.731E-07 NW 3.160E-05 9.797E-0 6 5.146E-06 2.636E-06 1.07CE-06 5.904E-07 3.800E-07 2.683E-07 2.016E-07 1.585E-07 1.288E-07 NNW 1.111E-05 3. 590E-0 6 1.929E-06 9.820E-07 3. 930E-0 7 2.129E-07 1. 349E-07 9.407 E-0 8 6.99 7E-08 5.450E-08 4.394E-08 N
1.064E-05 3.449E -0 6 1.897E-06 9. 684E-0 7 3. 8 78E-0 7 2.091E-07 1.320E-07 9.170 E-08 6. 800E-08 5. 28 3E-08 4.250E-0 8 l
1 NNE
- 9. 72 ;E-06 3.196E-06 1 72 7E-06 8.744E-07 3.4 70E-07 1.857E-07 1.164E-0 7 8.049E-08 5. 944E-08 4.601E-08 3.6 89E-0 8 NE 1.149 E-05 4.005E-06 2.197E-06 1.104E-06 4. 312E-07 2.27 8E-07 1.414E-0 7 9.695 E-08 7 106E-08 5.465E-08 4.357E-08 ENE 1.946E-05 3.440E-06 1.881E-06 9.439 E-0 7 3. 703E-07 1 965E-07 1.225E-07 8.425E-08 6.196E-08 4.779E-08 3.021E-08 1
E 1.510E-05 4.582E-06 2.462E-06 1.233E-06 4.894E-07 2.621E-07 1.646E-07 1.140E-07 8.431E-08
- 6. 537E-08 5. 251E-08 ESE 1.099E-05 3. 39 6E -0 6 1. 816E-06 9.151 E-0 7 3. 649 E-0 7 1.960E-07 1.2 34E-07 8. 5 55E-08 6.3 3 5E-08 4.916E-08 3. 9 51E -08 SE 1.071E-05 3. 4 74 E -0 6 1.8 71E-06 9.480E-07 3. 7 75E-0 7 2.031E-07 1.200E-07 8.885E-08 6.584E-08 5.112E-08 4.110E-08 1
SSE 1.423E-05 4.487E-06 2.426E-06 1. 249 E -0 6 5.0 7 5E-0 7 2. 77 4E-0 7 1. 7 70E-07 1.241E-C7 9.269F-08 7.247E-08 5.862E-0 8
)
4.JNU A L AvFPAGE CHl/0 (SEC/ METER CU8EDI DISTANCE IN MILES 6 EARING 5.000 7.500 10.000 15.000 20.000 25.000 30.000 35.000 40.000 45.000 50.00" i
5 1.038E-07 5.485E-0 8 3.621E-08 2.129 E-0 8 1.466E-08 1.100 E-08 8.700 E-09 7.143E-09 6.025E-09 5.187E-09 4.53 s9 SSW 9.295E-08 4.97 7E-08 3. 316E-08 1.974E-0 8 1.371E-08 1.035E-08 8.231E-09 6.787E-09 5.746E-C9 4.963E-09 4.354E-09 Sb 1.443E-07 7.653E-08 5.064E-08 2.988E-08 2.063E-08 1.550E-08 1.228E-08 1.010E-03 8.528E-09 7.350E-09 6.436E-09
)
WSW 2.149E-07 1.148E-07 7.6b9E-08 4.538E-08 3.146E-08 2.371E-08 1.884E-08 1.552E-08 1.313E-08 1.133E-08 9.936E-09 W
Z.604E-07 1. 396E-0 7 9.308E-08 5.545E-0 8 3. 850E-08 2.906E-08 2.311E-08 1.906E-08 1. 613E -0 8 1. 393 E -08 1. 222 E -0 8 WNb 1.447E-07 7. 714E -0 8 5.123E-08 3.036E-08 2.102E-08 1.582E-08 1.256E-08 1.034E-08 8.740E-09 7. 539E-09 6.607E-09 1
NW 1.0 74E-0 7 5.669E-0 8 3.740E-08 2.197E-08 1.511E-08 1.132E-08 8.952E-09 7.345E-09 6.192E-09 5.328E-09 4.659E-09 NNW 3.640E-08 1.875E-0 8 1.216E-0 8 6.982 E-09 4. 734E-09 3.509E-09 2. 7 50E-09 2. 240 E-09 1.877E-09 1. 60 6E-09 1. 3 98E-09 N
3.513E-08 1.795E-08 1.157E-08 6.590 E-09 4.440E-09 3.275E-09 2.556E-09 2.0 75E-09 1.733E-09 1.479E-09 1.284E-09
)
hNE 3.041E-08 1.539E-0 8 9. 85 eE-09 5.565E-09 3.732E-09 2.742E-09 2.135E-09 1.729E-09 1.441E-09 1 22 8E-09 1.065E-09 NE 3.572E-08 1.768E-08 1.114E-Oc 6.144E-0 9 4. 055 E-09 2.943 E-09 2.2 67E-09 1.820E-09 1.506E-09 1. 2 7 4E - 0 9 1.0 9 8E -0 9 ENE 3.142E-08 1.574E-08 1.002E-08 5. 613 t-0 9 3. 74 7E-0 9 2. 74 5E-09 2.132E-09 1.724E-09 1.435E-09 1.221E-09 1. 0 5 EE -0 9 E
4.336E-08 2.210E-08 1.424E-08 8.127E-0 9 5. 502E-09 4.076E-09 3.195E-09 2.603E-09 2.182E-09 1.869E-09 1.627E-09 ESE 3.264E-08 1.666E-08 1.0 74E-08 6.129E-09 4.144E-09 3.066E-09 2.401E-09 1.954E-09 1. 63 7E-09 1. 400 E -09 1. 219 E -0 9 SE 3.390E-08 1.732E-0 8 1 116E-08 6.355 E-09 4. 285E-09 3.16 2E-09 2.4 70E-09 2.0C 7E-09 1.677E-09 1. 43 3 E -09 1. 2 45 E -0 9 i
SSE 4.869E-06 2.532E-08 1.653E-08 9. 565E-09 6. 512E-09 4.841E-09 3.803E-09 3.104E-09 2. 60 4E-09 2. 2 31E-09 1. 944E-0 9 CHI /O ISEC/METEo CUBLO) FOR E AC H SEGMENT SEGMENT BOUNDARIES IN MILES DIRECllON
.5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 160M SITE S
4.910E-06 1.162E-06 3.778E-07 1.973E-07 1.253E-07 5.744F-08 2.166E-08 1.106E-08 7.162E-09 5.194E-09 LSW 4.291E-06 1.003E-06
(.333E-06 1.60 7E-06 5.228E-07 2.736E-07 1.741E-07 8.009E-08 3.038E-08 1.558E-08 1.013E-08 7.361E-09 WSW 5.8510-06 2.323E-06 7.656E-07 4.041E-07 2.586E-07 1.200E-07 4.608E-08 2.383E-08 1.556E-08 1.135E-08 W
1.181F-05 2.782E-06
- 9. 214E-0 7 4.880E-07 3.130E-07 1 458E-C7 5.62eE-08 2.920E-08 1.910E-08 1.395E-08 kNW 6.co9E-06 1.576F-05 5.181E-07 2.728E-07 1.743E-07 8.065F-08 3.085E-08 1.590E-08 1.036E-08 7.550E-09 NW 5.064E-C6
- 1. 2 0 5E-06
- 3. 914E -0 7 2.042E-07 1.296E-07 5.938E-08
- 2. 2 3 5E -0 0 1.138E-08 7.365E-09 5.336E-09
~
NNW 3.6 7 7E -06 4.438E-07
- 1. 394E-0 7 7.096E-08 4.428E-08 1.974E-C8 7.134E-09 3.532E-09 2.247E-09 1.609E-09 N
1.829E-06
- 4. 3 74 E-07
- 1. 3 6 4E -0 7 6.899E-08 4.263E-08 1 893E-08 6.742E-09 3.29eE-09 2.082E-09 1.482E-09 s
hNE 1.674E-06 3.925E-07
- 1. 20 5E-0 7 6.034E-08
- 3. 719 E-0 8 1.627E-08 5.704E-09 2.763F-09 1.735E-09 1.231E-09 NE 2.113E-06 4.904E-07
- 1. 46 7 E -0 7 7.221E-08 4.3940-08 1.878E-08 6.325E-09 2.969E-09 1.828E-09 1.278E-09 ENE 1.811E-96 4.205E-07
- 1. 2 69E-0 7 6.293E-08 3.85 r-08
- 1. 66 8 E-0 8 5.761E-09 2.767E-09 1.731E-09 1.224E-09
-s E
2.387F-Oo 5.536E-07
- 1. 704E-0 7 8.556E-08 5.293E-08 2.333E-08 8.319E-C9 4.104E-09 2.612E-09 1.872E-09 ESE 1.767E-06 4.121E-07
- 3. 2 7oE-07 6.429E-08 3.983E-08 1.758E-08
- 6. 2 72 E -09 3.087E-09 1.961E-09 1.403E-09 SE 1.817E-06 4.268E-07
- 1. 3 24E-0 7 6.681f-08 4.142E-08
- 1. 8 2 8 E-E 8 6.503E-09 3.185E-09 2.014E-09 1.436E-09 SSE 2.361E-06 5.700E-07
- 1. 8 2 6E-0 7 9.396E-08 5.905E-08
- 2. 660 E-0 8 9.755E-09 4.872E-09 3.113E-09 2.235E-09