U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region I Report No.
70-820/79-02 Docket No.70-820 Safeguards Group:
1 License No.
SNM-777 Priority 1
Category UR Licensee:
United Nuclear Corooration Fuel Recovery Doeration Wood River Junction, Rhode Island Facility Name:
United Nuclear Corporatio. - FR0 Inspection at:
Wood River Junction Inspection conducted:
January 22-26, 1979 j
Inspectors:
Mdb.
b 'l b ~ 2 f, W. Madden, Physicar Security Inspector date signed d ( A~-
3
~26 7T M. Rogers, Phy ical. Security Inspector date sigrfed
~~
date signed M/
Approved b A 4 '--
~
r_
c
'I Devlin, Chief, Security and Investigations, date 'signp Safeguards Branch InspectiorsSummary: -
Inspection on January 22-26, 1979 (Recort No. 70-820/79-02)
Areas Inspected:
Routine, unannounced Physical Protection Inspection, (Section I)
Implementation of Security Plan, Se.curity Oraanization, Physical Barriers, Access Controls, Keys, Locks and Combinations, Detection Aids, Response Controls, Central Alarm and Communications System, Testing and Maintenance, SNM Protection, Records and Reports and Reports of Incidents.
(Section II) Followup-up review of licensee re-sponse actions to USNRC (Region I) Immediate Action Letter issued October 16, 1978.
(Section III) Follow-up review of Physical Protection Program improvements relevant to USNRC (Region I) Inspection Reports Nos. 70-820/78-10 (Confidential-NSI) dated April 24,1978 and 70-820/78-15 (Confidential-NSI) dated August 1,1978.
(Section IV)
Follow-up review of licensee actions taken as a result of the USNRC's "Special Safeguards Review of UNC's Fuel Recovery Operation" (Confidential-NSI) conducted between October 31 and November 3, 1978.
The inspection was initiated during non_
regular hours and involved 72 inspector-hours on site by two NRC regional based inspecto Results: Of the thirteen areas inspected, no items of noncompliance were identified.
Region I Form 12 (Rev. April 77) 7906210055 2240 151
_