- 11. 1 Qig pg,g Power Supply Engineering and Services
... va.n.~
May 9, 1979 United States Nuclear Regulatory Ccanission Of fice of Inspection and Enforcement Region II - Suite 3100
REFERENCE:
101 Marietta Street RII: JP0 Atlanta, GA 30303 50-424 50-425 Attn: Mr. James P. O'Reilly Gen tlenen:
The following is submitted in response to your letter dated March 12, 1979, concerning IE Bulletin 79-03.
The numbered responses _belcw corre-spond to the numbered action items contained in the Bulletin.
1.
Four (4) spools manufactured by Youngstown Melding and Engineering Ccapany from stainless steel welded pipe (without filler material), ASME SA-312 Type 304, are used in the fabrication of piping subassemblics for Vogtie Nuclear Plant, Unit No.1.
Spool Mark No.
Shoo Owg. No.
Area D'..g.
No.
Descrhtticy 1-1205-041-5-01 F-418 1X4DL4D08 14" NPS W/20" S td. Wt. Sleeve 1-1205-042-S-01 F-419 1X4DL4008 14" NPS U/20" Std. Wt. Sleeve 1-1206-001-S-01 F-411 1X4DL4008 12" NPS W/18" Std. Ut. Sleeve 1-1206-002-5-01 F-412 IX4DL4008 12". NPS W/8" Std. Ut. Sleeve All of the piping purchased by Westinghouse is of seamless cons tru c tion.
2.
These spools are being used in the fabrication of jacketed piping in the Containment Spray System (1206) and the Residual Heat Removal System (1205).
The piping will be embedded in the concret?
containnent basemat and serves a s the suction line betweg the containment sumps and the containment spray pumps and res<idual heat removal pumps during recirculation. The spools are designed in accordance with the 1974 edition of the ASME Code,Section III, Class 2 (including Maenda through Sunmer 1975) and Code Case N-52.
2345 300 290e140c30 wa cm
~
Mr. James P. O'Reilly U. S. fluclear Regulatory Comnission flay 9, 1979 Page Two 3.
The subject pipe spools have undergone 100% radiographic inspection of the ic,o* cudinal weld sean and have been accepted by the resident Bechtel quality inspector. Additionally, Youngstown Welding and Engineering Company has been removed from the fabricator's (Pullman Pcwer Products) approved bidder's
- list, g e.
truly y V
/
/
40 c
.' W. haff ianag if Qua y Assurance Ct!H:aaw xc:
U. S. Nuclear Regulatory Conmission Office of Inspection and Enforcement Division of Reactor Operations Inspection Washing ~ ton, D.C. 20555 2345
.501 I