ML19270G219

From kanterella
Jump to navigation Jump to search
Amend 12 to License R-23 Extending Duration of License Until 970826 & Incorporating Security Plan
ML19270G219
Person / Time
Site: Texas A&M University
Issue date: 04/25/1979
From: Grimes B
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19270G216 List:
References
R-023-A-012, R-23-A-12, NUDOCS 7906050150
Download: ML19270G219 (29)


Text

. _.... _. _ _ _.. _..

f UNITED STATES O

2**

NUCLEAR REGULATORY CCMM!sslON f

j WM : 'CN, D.20555 0 Q../l TEXAS A&M UNIVERSITY 00CXET NO. 50-59 AMENDED FACILITY OPERATING LICENSE Am ment No.12 License No. R-23 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Texas A&M university (the licensee) dated May 31, 1977, as supplemented by filings dated September 29, 1978, December 11, 1978 and December 18, 1978, and March 23, 1979, compliese with the standards.and requirements _of_.the Atomic Energy 3

l Act of 1954, as amended (the Act), ano the Comission's regulations i

set forth in 10 CFR Chapter I; B.

The facility will operate in confomity with the applicatien, the provisions of the Act, and the regulations of the Comission; C.

There is reasonable assurance (1) that the actiYities authorized by this amendment can be conducted without endangering the health and safety of the public, and (11) that such activities will be conducted in compliance with the Comission's regulations; D.

The licensee is technically and financially qualified to engage in the activities authorized by this operating license in accor-I dance with the regulations of the Commission; l

E.

The licensee is a nonprofit educational institution, and will use the facility for the conduct of educational activities, and has satisfied the applicable provisions of 10 CFR Part 140, " Financial Protection Requirements and Idemnity Agreements," of the Comission's regulations; F.

The issuance of this amendment will not be inimical to the ccmon defense and security or to the health and safety of the public; G.

The issuance of this amendment is in accordance with 10 CFR Par 51 of the Comission's regulations and all applicable requirements have been satisfied. and H.

The receipt, possession an'd use of the bycreduct and special nuclear materials as authori:ed by this license will be in acccrdance with the Commission's regulations in 10 CFR Parts 30 and 70, including 10 CFR Sections 30.33, 70.23 and 70.31.

6 0 5 0 IS$ SO.-

s

. 2.

Facility License No. R-23 is hereby amended in its entirety to read:

A.

This license applies to the homogeneous nuclear reactor model AGN-20lM, Serial No.106 (the reactor), owned by the Texas A&M University (the. licensee), located on its campus at Coilege Station, Texas and described in the application for license dated June 13, 1957, and subsequent amendments and supplements thereto, including the application for license renewal dated May 31, 1977, and supplements thereto dated September 29, December 11 and December 18, 1978, and March 23, '979.

~

B.

Subject to the conditions and requirements incor;: orated herein, the Ccmission hereby licenses the Texas ALM University:

(1) Pursuant to Section 104c of the Act and 10 CFR, Chapter 1, Part 50, "Licens!ng of Production and Utilization Facilities",

to possess, use and operate the reactor as a utilization facility at the designated location in College Station, Texas, in accordance with the procedures and limitations set forth in this license.

(2) Pursuant to the Act and 10 CFR Part 70, "Special Nuclear Material," to receive, possess, and use up to 700 grams of contained uranium 235, enriched to less than 20 percent in uranium dioxide (U0 embedded in radiation stabilized polyethylene, and up t$)16 grams of plutonium 239 in the form of a sealed Pu-Be neutron source, both in connection with operation of the. reactor.

(3) Pursuant to the Act and 10 CFR Parts 30 and 70 to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the reactor.

C.

This license shall be deemed to contain and 'is subject to the conditions specified in the folicwing Comission regulations in i

10 CFR Chapter I: Part 20, Section 30.34 of Part 30, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, 1

and orders cf the Cennission now or hereafter in effect; and is subject l

to the additional conditions specified or incorporated below:

i (1) Maximum Power Level The licensee is authorized to operate che reactor at steady-state pcwer levels up to a maximum of 5 watts (thermal).

e

n

.. (2) Technical Scecifications The Technical Specifications contained in Appendix A attached hereto are hereby incorporated in this license.

The licensee shall operate the reactor in accordance with the Technical Specifications.

D.

The licensee shall maintain in effect and fully inclement all provisions of the NRC-approved physical security plan, including amendments and changes made purstant to the authority of 10 CFR 50.54(p). The approved security plan consists of the document withi. ld frcm public disclosure pursuant to 10 CFR 2.790(d),

entitled " Security Plan for The Texas A&M University AGN-20lM Reactor Facility", dated September 13, 1974.

E.

This amended license is effective as of the date of issuance and shall expire at midnight, August 26, 1997.

FOR F NUCLEAR REGULAT.RY COMMISSION Brian K. Grimes, Assistant Director for Engineering & Projects Division of Operating Reactors

Attachment:

Appendix A - Technical Specifications dated Date of Issuance: April 25,1979 i

I o

APPENDIX A LICENSE NO, R-23 TECHNICAL SPECIFICATIONS FOR TEXAS A&M UNIVERSITY AGN-20lM REACTOR (SERI AL 4106)

DOCKET NO. 50-59 A=end en: No. 1 Dated: April 25, 1979

e TA31I CF CONTENTS PACE 1.0 DEFINITIONS.

1 2.0 SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETIINGS.

4 4

2.1 Safety Limits 2.2 Limiting Safety System Settings 4

3.0 LIMITING CONDITIONS FOR OPERATION.

5 3.1 Reactivity Limits 5

3.2 Control and Safety Systems.

6 9

3.3 Limitations on Experiments.

3.4 Radiation Monitoring, Control, and Shielding.

10 4.0 SURVEILLANCE REQUIREMENTS.

11 4.1 Reactivity Limits 11 4.2 Control and Safety Systems.

12 4.3 Reactor Structure.

13 4.4 Radiation Monitoring and Control.

13 5.0 DESIGN FEATURES.

14 5.1 Reactor.

14 15 5.2 Fuel Storage.

5.3 Reactor Room, Reactor Control Room, Accelerator Room 15 6.0 ADMINISTRATIVE CONT 30LS.

15 6.1 Organization.

15 6.2 eaff Qualifications.

19 r

6.3 Training.

19 6.4 Reactor Safety Board.

19 6.5 Approvals.

21 6.6 Procedure s.

21 6.7 Experiments 21 6.8 Safety Limit Violation.

22 6.9 Reporting Requirements.

22 6.10 Record Retention.

25

1.0 DEFINITICNS The terms Safety Limit (SL), Limiting Safety System Setting (LSSS),

and Limiting Conditions for Operation (LCO) are as defined in 50.36 of 10 CFR Part 50.

1.1 Channel Calibration - A channel calibration is an adjustment of the enannel sucn tnat its output responds, within acceptable range and accuracy, to known values of the parameter which the channel measures. Calibration shall enecmpass the entire channel, including equipment, actuation, alarm, or trip.

1.2 Channel Check - A channel check is a qualitative verification of acceptacle performance by observation of annel behavior. This verification may include comparison of th. channel with other independent channels or methods measuring the same variable.

1.3 Channel Test - A channel test is the introduction of a signal into

.the enannel to verify that it is operable.

1.4 Exoeriment -

a.

An experiment is any of the following:

(1) An activity utilizing the reactor system or its components or the neutrons or radiation generated therein; (2) An evaluation or test of a reactor system operational, surveillance, or maintenance technique; (3) An experimental or testing activity which is conducted within the confinement or containment system of the reactor; or (4) The material content of any of the foregoing, including structural components, encapsulation or confining boundaries, and contained fluids or solids, b.

Secured Exoeriment - Any ex;eriment, or component of an excer1 ment is deemed to be secured, or in a secured position, if it is held in a stationary position relative to the reactor by mechanical means. The restraint shall exert sufficient force on the experiment to overcome the expected effects of hydraulic, pneumatic, bouyant, or other forces which are normal to the operating environment of the experiment or which might arise as a result of credible malfunctions.

c.

Unsecured Exceri ent Any experiment, or ccmoonent of en experiment 1s ceemed to be unsecured wnenever it is not secured as defined in 1.4.b.

above. woving : arts of ex:eriments are deemed to be unsecured when they are in motion.

1

a d.

Movable Ex:eriment - A movable experiment is one which may be inserted, removed, or manipulated while the reactor is critical, e.

Removable Exceriment - A removable experiment is any experiment, experimental facility, or component of an experiment, other than a pemanently attached apourtenance to the reactor system, which can reasonably be anticipated *^ be moved one or more times during the life of the reactor.

1.5 Excerimental Facilities - Experimental facilities are those portions of the reactor assemoly that are used for the introduction of experi-ments into or adjacent to the reactor core region or allow beams of radiation to exit from the reactor shielding. Experimental facilities shall include the ther nal column, glory hole, and access ports.

w terial - Explosive material is any solid or liquid 1.6 Exolos tve a

wnicn is categartzed as a Severe, Cangerous, or Very Dangerous Explosion Hazard in " Dangerous Properties of Industrial Materials" by N. L. Sax, Third Ed. (1968), or is given an Identification of Reactfvity (Stability) index of 2, 3, or 4 by the National Fire Protection Association in its publication 704-M 1966, "Identifica-tion System for Fire Ha:ards of Materials," also enumerated in the

" Handbook for Laboratory Safety" 2nd Ed. (1971) published by The Chemical Rubter Company.

1.7 Measurtna Channel - A measuring channel is the combination of sensor, lines, amplifiert, and output devices which are connected for.the purpose of measuring or responding to the value of a process variable.

1.8 Ocerable - Cperable means a component or system is capable of per-forming its intended function in its normal manner.

1.9 Oceratino.- Coerating means a component er system is performing its intended function in its normal manner.

1.10 Potentf al Reactivity 'Jorth - The poter.tial reactivity worth of an experiment 12 the maxfmum absolute value of the reactivity change that would occur as a result of intended or anticipated changes or credible malfunctions that alter experiment ;osition or configuration.

Evaluations of potential reactivity worth of experiments also shall include effects of possible trajectories of the experiment in motion relative to the reactor, its orientation along each trajectory, and circumstances which can cause internal changes such s creating or filling of void spaces or motion of mechanical compe fnts. For re-movable experiments, the potential reactivity worth is equal to or greater than the static reactivity worth.

1.11 Reactor cemeen aj - A reactor cocoonent is any apoaratus; device, or mater 1al tnat is a normal part of the reactor assembly.

1.12 Resctor 0:eratton - Reactor operation is any condition wnerein

ne reactor fs not shut dcwn.

2

1.13 Reacter Safety Svstem - The reactor safety system is that combination of safety channels and associated circuitry which forms the automatic protective system for the reactor or provides information wnich requires manual protective action be initiated.

1.14 Reactor Shutdcwn - The reactor shall be considered shutdown whenever 4.

either:

1.

All safety and control rods are fully withdrawn from the core, or 2.

The core fuse melts resulting in separation o ' the

core, and:

b.

The reactor console key switch is in the "off" position and the key is removed from the console and under the control of a licensed operator or the Reacter Administrator.

1.15 Safety channel - A safety channel is a measuring channel in the reactor safety system.

Static Reactivit Worth - The static reactivity worth of an 1.16 experiment is the acsolute value of the reactivity change which is measurable by calibrated control or regulating rod comparison methods between two defined terminal positions or configurations For recavable experiments, the terminal posttions of the experiment.

are fully removed from the reactor and fully inserted or installed in the normal functioning or intended position.

3

2.0 S AFETY LIMITS AND LIM 7I'ING S AFETY SYSTEM SETTINGS 2.1 Safety Limits Aeolicability This specification applies to the maxi =um steady state power level and maximum core temperature during steady state or transient opera-tion.

Objective To assure that the integrity of the fuel caterial is maintained and all fission products are retained in the core matrix.

Soecification a.

The reactor power level shall not exceed 100 watts.

b.

The maximum core temperature shall not exceed 2000C during either steady state or transient operation.

Bases The polyethylene core material does not melt below 2000C and is expected to maintain its integrity and retain ess<ntially all of the fission products at temperatures below 2000C. T ne Hazards Su= mary Report dated February 1962 submitted on Docket F-15 by Aerojet-General Nucleonics (AGN) calculated a steady state core average temperature rise of 0.44 C/vatt.

Therefore, a steady state power level of 100 watts vould result in an average core temperature rise of 440C. The corresponding maximum core temperature would be below 2000C thus assuring integrity of the core and retention of fission products.

2.2 Limiting Safety System Settings Applicability This specification applies to the parts of the reactor safety system which will limit maximum power and core temperature.

Obiective To assure that automatic protective action is initiated to prevent a safety limit from being exceeded.

Specification a.

The safety channels shall initiate a reactor scram at the following limiting safety system settings:

4

Channel Condition LSSS 10 watts Nuclear Safety d2 High Power 10 watts Nuclear Safety #3 High Power b.

The core thermal fuse shall melt when heated to a temperature of about 120 C resulting in core separation and a reactivity loss greater than 5% ak.

Bases Based on instrumentation response times and scram tests, the ACN Ha:ards Re port concluded that reactor periods in excess of 30-50 milli-seconds would ba adequately arrested by the scram system. Since the maxi =um avail-able excess reactivity in the reactor is less than one dollar the reactor cannot become prompt critical and the corresponding shortest pos sib le period is greater than 200 milli-seconda. The high power LSSS of 10 watts in conjunction with automatic safety systems and/or manual scram capabili-ties will assure that the safety limits will not be exceeded during steady state or as a result of the most severe credible transient.

In the event of failure of the reactor to scram, the self-limiting charac-teristics due to the high negative temperature coefficient, and the melt-ing of the thermal fuse at a temperature below 1200C will assure safe shutdown without exceeding a core temperature of 200C..

3.0 LIMITING CONDITIONS FOR OPERATION 3.1 Reactivity Limits Apolicability This specification applies to the reactivity condition of the reactor and the reactivity worths of control rods and experiments.

Ob iec tive To assure that the reactor can be shut down at all times and that the safety Itmits will not be exceeded.

Soecification The available excess reactivity with all control and safety rods s.

fully inserted and including the potential reactivity worth of all experiments shall not exceed 0.65% a k/k referenced to 20 C.

b.

The shutdevn margin with the most reactive safety or control rod fully inserted shall be at least 1% a k/k.

The reactivity worth of the control and safety rods shall ensure sub-c.

criticality on the withdrawal of the coarse control rod or any one safety rod.

5

Bases The limitations on total core excess reactivity assure reactor periods of suf ficient length so that the reactor protection system and/or operator action will be able to shut the reactor down without exceeding any safety limits. The shutdown margin and control and ss.fety rod reactivity li=itations mesure that the reactor can be brought and maintained suberitical if the highest reactivity rod fails to scram and remains in its most reactive position.

3.2 Control and Safety Systems Apolicability These specifications apply to the reactor control and safety syste=2.

Obtective To specify lowest acceptable level of performance, instrument set points,

and the mini =um number of operable components for the reactor control and safety systems.

Specification a.

The total scram withdrawal time of the safety rods and coarse control rod shall be less than 200 milliseconds.

b.

The average reactivity addition rate for each control or safety rod shall not exceed 0.065% a k/k per second.

c.

The safety rods and coarse control rod shall be interlocked such that:

1.

Reactor startup cannot cocmence unless both safety rods and coarse control rod are fully withdrawn from the core.

2.

Only one safety rod can be inserted at a time.

3.

The coarse control rod cannot be inserted unless both safety rods are fully inserted.

All reactor safety systes in trumentatica shall be operable in accordance d.

s with Table 3.1 whenever the reactor control or safety rods are not in their fully withdrawn position.

e.

The shield water level interlock shall be set to prevent reactor start-up and scram the reactor if the shield water level falls 10.5 inches below the highest point on the reactor shield tank manhole opening.

f.

The shield water temperature interlock shall be set to prevent reactor startup and scram che reactor if the shield water temperature falls below 150C.

6

.e

  • ew

-w-

.0+

m-4e

..as m

,w

TABLE 3.1

~

Safety Channel Set Point Function Nta:1 car Safety #1 Lcw count rate

> 10 cps scran belcw 10 cps Nuclear Safety #2 High power 1 10 watt scram at pcwer >10 watt

-12 Iow power 1 1.0 x 10 a=ps scram at source levels

< l.0 x 10-12 a=ps Reactor period

> 5 sec scram at periods < 5 sec Nuclear Safety #3 (Linear Power) liigh Power

< 10 watt scram at power > 10 watt low power

> 5% full scale scram at source levels

< 5% of full scale scram at operator option Mutual scram 7

g.

The seismic displacement interlock shall be installed in such a manner to prevent reactor startup and scram the reactor during a seismic displacement, h.

A loss of electric power shall cause the reactor to scram.

Bases The specifications on scram withdrawal time in conjunction with the safety system instrumentation and set points assure safe reactor shutdown during the most severe foreseeable transients. Interlocks on control and safety rods assure an orderly approach to criticality and an adequate shutdown capability. The limitations on reactivity addition rates allow only relatively slow increases of reactivity so that ample time will be avail-able for manual or automatic scram during any operating conditions.

The neutron detector channels (nuclear safety channels 1 through 3) assure that reactor power levels are adequately monitored during reactor startup and operation. Requirements on mini =um neutron levels will prevent reactor startup unless channels are operable and responding, and will cause a scram in the event of instrumentation f ailure. The power level scrams initiate redundant automatic protective action at power level scrams low enough to assure safe shutdown without exceeding any safety limits. The period scram conservatively limits the rate of rise of reactor power to periods which are manually controllable and will automatically scram the reactor in the event of unexpected large reactivity additions.

The AGN-201's negative temperature coef ficient of reactivity causes a reactivity increase with decreasing core temperature. The shield water temperature interlock will prevent reactor operation at temperatures below 15 C thereby limiting potential reactivity additions associated with temperature decreases.

Water in the shield tank is an important component of the reactor shield and operation without the water may produce excessive radiation levels.

The shield tank water level interlock will prevent reactor operation with-out adequate water levels in the shield tank.

The reactor is designed to withstand 0.6g accelerations and 6 cm displace-ments. A seismic instrc=ent causes a reactor scram whenever the instru-ment receives a horizontal acceleration that causes a horizontal displace-ment of 1/16 inch or greater. The seismic displacement interlock assures that the reactor will be scrammed and brought to a suberitical configura-tion during any seismic disturbance that may cause damage to the reactor or its components.

The manual scram allows the operator to manually shut down the reactor if an unsafe or otherwise abnormal condition occurs that does not otherwise scram the reactor. A loss of electrical power de-energizes the safety and coarse control rod holding magnets emusing a reactor scram thus assuring safe and immediate shutdown in case of a power outage.

8

3.3 LLmitations on Experiments Apolicability This specification applies to experiments installed in the reactor and its experimental facilities.

Obiective To prevent damage to the reactor or excessive release of radioactive materials in the event of an experiment failure.

Specification a.

Experiat its containing esterials corrosive to reactor components or which cont:in liquid or gaseous, fissionable materials shall be doubly encapsulated, b.

Explosive materials shall not be inserted into experimental f acilities of the reactor or stored within the confines of the reactor f acility, c.

The radioactive material content, including fission products of any experiment shall be limited so that the complete release of all gaseous, particulate, or voittile components from the experiment will not result in doses in excess of 107 of the equivalent annual doses stated in 10 CFR Part 20 for persons occupying (1) unrestricted areas continuously for two hours starting at time of release or (2) restricted areas during the length of time required to evacuate the restricted area.

d.

The radioactive material content, including fission products of any doubly encapsulated experiment shall be limited so that the ecmplete release of all gaseous, particulate, or volatile components of the experiment shall not result in exposures in excess of 0.5 rem whole body or 1.5 rem thyroid to persons occupying an unrestricted area continuously for a period of two hours starting at the time of release,

or exposure in excess of 5 rem whole body or 30 ren thyroid to persons occupying a restricted area during the length of time required to evacuate the restricted area.

Bases These specifications are intended to reduce the likelihood of damage to reactor components and/or radioactivity releases resulting from an experi-ment failure and to protect operating personnel and the public from excessive radiation doses in the event of an experi=ent failure.

9

3.4 RADIATION MONITORING, CO?CROL, MD SHIELDING Apolicability This specification applies to radiation =enitoring, control, and reactor shielding required during reactor operation.

Ob iective To protect facility personnel and the public frem radia-tion exposure.

S peci fication An operable portable radiation survey instrument capable of detecting a.

gamma radiation shall be i= mediately available to reactor operating personnel whenever the reactor is not shutdevn.

b.

The reactor room and 4ccelerator room shall be considered restricted areas whenever the reactor is not shutdown.

c.

The accelerator room shall be considered a radiation area whenever the reactor is not shutd/wn.

d.

The reactor room shall be considered a radiation area whenever the reactor is operated at a power level less than 0.9 watts, e.

Whenever the reactor is operated at a power level equal to or greater than 0.9 watts the reactor room shall be considered a high radiation area and the reactor room entrance shall be equipped with a control device which shall energize a conspicuous visible and audible alarm signal in such manner that the individual entering the reactor room and the reactor operator are made aware of the entry, or the reactor room entrance shall be maintained locked except during periods when access to the area is required, with positive control over each entry.

f.

The following shielding requirements shall be fulfilled during reactor operation:

1.

The reactor shield tank shall be filled with water to a height within 10 inches of the highest point on the manhole opening.

2.

The thermal column shall be filled with water or graphite except during a critical experiment (core loading) or during other ap-proved experiments requiring the ther=al column to be empty.

Bases Radiation surveys performed under the supervision of a qualified health physicist have shown that the ca tal ge=sa, thermal neutron, and f ast neutron radiation dose rate in the reactor room, at the closest approach to the reactor, is less than 100 mres/hr at reactor power levels less than 1.0 10

watt, and that the total gamma, thermal neutron, and fast neutron dose rate in the accelerator room is less than 15 = rem /hr at reactor power levels less than or equal to 5.0 watts and the thermal column filled with water.

The facility shielding in conjunction with radiation monitoring, control, and restricted areas is designed to limit radiation doses to facility personnel and to the public to a level below 10 CFR 20 limits under operat-ing conditions, and to a level below criterion 19, Appendix A,10 CFR 50 recommendations under accident conditions.

4.0 SURVEIllR;CE REQUIREMEhis Actions specified in this section are not required to be performed if during the specified surveillance period the reactor has not been b rought critical or is maintained in a shutdown condition extending beyond the specified surveillance period. However, the surveillance requirements must be fulfilled prior to subsequent startup of the reacte.

4.1 Reactivity Limits Apolicability This specification applies to the surveillance requirecents for reactivity limits.

Ob jective To assure that reactivity limits for Specification 3.1 are not exceeded.

Specification a.

Safety and control red reactivity worths shall be measured annually, but at intervals not to exceed 16 months, b.

Total excess reactivity and shutdown margin shall be determined annually, but at intervals not to exceed 16 months.

c.

The reactivity worth of an experiment shall te esti=ated or measured, as appropriate, before or during the first startup subsequent to the experiment's insertion.

Bases The control and safety rods are inspected and their reactivity worths are measured annually to assure that no degradation or unexpected changes have occurred which could adversely affect reactor shutdown margin or total excess reactivity. The shutdown =ar;in and total excess rasctivity are determined to assure that the reactor can always be safely shut down with one rod not functioning and that the maxi =um possible reactivity insertion will not result in reactor periods shorter than thosa that can be adequately ter=inated by either operator or automatic action.

Based on experience with AGN reactors, significant changes in reactivity or rod worth are not expected within a 16-month period.

11

4.2 control and Safety Systems Apolicability This specification applies to the surveillance require =ents of the reactor control and safety systems.

Ob iect ive To assure that the reactor control and safety systems are operable as required by Specification 3.2.

Seccification Safety and control rod scram tices and average reactivity insertion a.

rates shall be measured annually, but at intervals not to exceed 16 months.

b.

Safety and control rods and drives shall be inspected for deterioration at intervals not to exceed 2 years.

c.

A channel test of the follet'ing safety channels shall be performed prior to the first reactor startup of the day or prior to each reactor operation extending more than one day:

Nuclear Safety 41, 42, and 43 Manual scran d.

A channel test of the seismic displacement interlock shall be performed semiannually.

A channel check of the f ollowing safety channels shall be performed e.

daily whenever the reactor is in operation:

Nuclear Safety #1, #2, and #3 f.

Prior to each day's reactor operation or prior to each reactor operation extending more than one day, safety red 41 shall be inserted and scra=ced to verify operability of the manual scram system.

g.

The period, count rate, and power level measuring channels shall be calibrated and set points verified annually, but at intervals not to exceed 16 months.

  • h.

The shield tank water level interlock, shield water temperature interlock and seismic displace =ent saf ety channel shall be calibrated by perturbing the sensing element to the appropriate set point. These calibrations shall be performed anually, but at intervals not to exceed 16 =caths.

12

Bases The channel tests and checks required daily or before each startup will assure that the safety channels and scram functions are operable. Based on operating experience with reactors of this type, the annual scram measurements, channel calibrations, set point verifications, and in-spections are of sufficient frequency to assure, with a high degree of confidence, that the safety system settings will be within acceptable drift tolerance for operation.

4.3 Reactor Structure Aeolicability This specification applies to surveillance requirements for reactor components other than control and safety rods.

Obtective To assure integrity of the reactor structures.

Soecification a.

The shield tank shall be visually inspected every two years. If apparent excessive corrosion or other damage is observed, corrective measures shall be taken prior to subsequent reactor operation.

b.

Visual inspection for water leakage from the shield tank shall be per-formed annually. Leakage shall be corrected prior to subsequent reactor operation.

Bases Based on experience with reactors of this type, the frequency Z inspection and leak test requirements of the shield tank will assure capability for radiation protection during reactor operation.

4.4 Radiation Monitorine and Control Applicability This specification applies to the surveillance requirements of the radiation monitoring and control systems.

Objective To assure that the radiation conitoring and control syste=s are operable and that all radiation and high radiation areas within the reactor facility are identified and controlled as required by Specification 3.4 13

S peci fic a tion a.

All portable radiation survey instruments assigned to the reactor f acility shall be calibrated under the supervision of the Radiological Safety Of ficer annually, but at intervals not to exceed 16 months, b.

Prior to each day's reactor operation or prior to each reactor opera-tion extending more than one day, the reactor room high radiation area alarm shall be verffied to be operable.

c.

A radiacion survey of the reactor room, reactor control room, and accelerator room shall be performed u:. der the supervision of the Radiological Safety Office r annually, but at intervals not to exceed 16 months, to determine the location of radiation and high radiation areas corresponding to reactor operating power levels.

Bases The periodic calibration of radiation monitoring equipment and the surveil-lance of the reactor room high radiation area alarm will assure that the radiation monitoring and control systems are operable during reactor operation.

The periodic radiation surveys will verify the location of radiation and high radiation areas and will assist reactor facility personnel in properly labeling and controlling each location in accordance with 10 CFR 20.

5.0 DESIGN FEATUPIS 5.1 Reactor The reactor core, including control and safety rods, contains approxi-a.

mately 660 grams of U-235 An the form of <20% enriched UO dispersed 2

in approximately 11 kilograms of polyethylene. The lower section of the core is supported by an aluminum rod hanging from a fuse link.

The fuse melts at a fuse temperature of about 1200C causing the lower core section te f all away from the upper section reducing reactivity by at least 57. a k/k. Sufficient clearance berween core and reflector is provided to insure free fall of the bottom half of the core during the most severe transient.

b.

The core is surrounded by a 20 cm thick high density (1.75 gm/cm3) graphite reflector followed by a 10 cm thick lead ga=ma shield. The core and part of the graphite reflector are sealed in a fluid-tight aluminum core tank designed to contain any fission gases that might leak from the core.

c.

The core, reflector, and lead shielding are enclosed in and supported by a fluid-tight steel reactor tank. An upper or " thermal colu=n tank" may serve as a shield tank when filled with water or a thermal column when filled with graphite.

14

d.

The 6 foot diameter, fluid-tight shield tank is filled with water constituting a 55 cm thick fast neutron shield. The fast neutron shield is formed by filling the tank with approxi=ately 1000 gallons of water. The complete reactor shield shall limit doses to operating personnel in restricted and unrestricted areas to levels less than permitted by 10 CFR 20 under operating conditions.

Two safety rods and one control rod (identical in size) contain less e.

than 20 grams of U-235 each in the same form as the core caterial.

TheJe rods are lif ted into the core by electromagnets, driven by reversible DC motors through lead screw asse=blies. Deenergizing the magnets causes a spring-driven, gravity-assisted scram. The fourth rod or fine control rod (approximately one-half the diameter of the other rods) is driven directly by a lead screw. This red may contain fueled or unfueled polyethylene.

5.2 Fuel Storare Fuel, including fueled experiments and fuel devices not in the reactor, shall be stored in locked rooms in the nuclear engineering department is no greater laboratories. The storage array shall be such that K ff than 0.8 for all conditions of moderation and reflection.

5.3 Reactor Room, Reactor Control Room, Accelerator Room The reactor room houses the reactor asse=bly and accessories required a.

for its operation and maintenance, b.

The reactor control room houses the reactor control console.

c.

The accelerator room is directly above the reactor room and a hole in the accelerator room floor provides access to the ther=al colu=n.

d.

The reactor room, reactor control room, and accelerator room are separate rooms in the Zachry Engineering Center, constructed with adequate shielding and other radiation protective features to Ibnit doses in restricted and unrestricted areas to levels no greater than permitted by 10 CFR 20, under normal operating conditions, and to a level below criterion 19, Appendix A,10 C7R 50 recommendations under accident conditions, e.

The access doors to the reactor room, reactor control room, and accelerator room shall contain locks.

6.0 ADMINISTRATIVE CONIiROLS 6.1 Orzanization The administrative organization for control of the reactor facility and its operatirn shall be as set forth in Figure 1 attached hereto. The authorities and responsibilities set forth below are designed to comply with the intent and requirements for ad=inistrative controls of the reactor facility as set forth by the Nuclear Regulatory Coesission.

15

FIGURE 1 Administrative Organization of the Texas AS' Ltiversity AGN-20DI Reactor Facility hRC License R-23 President Texas AQi University 16diological Dean Reactor Safety Board College of Safety Board Engineering i

i i

I 3

1 I

I i

Head I

Department of J

hbclear Engineering Reactor Supervisor

  • I aDaCtor Cperators **

I Requires NRC Senior Operators License Rcquires NRC Operators License except wht.,a exempt per 10 CFR 55 paragraph 55.9 16

6.1.1 Pre sident The President is the chief administrative officer responsible for the University and in whose name the application for licensing is made.

6.1.2 Dean, college of Engineering The Dean of Engineering is the administrative of ficer responsible for the operation of the College of Engineering.

6.1.3 Head, Department of Nuclear Engineering The Head of the Department of Nuclear Engineering is the administrative of ficer responsible for the operation of the Department of N2 clear Engineering, including the AGN-20lM Reactor Facility. In this capacity he shall have final authority and ultimate responsibility for the operation, maintenance, and safety of the reactor facility within the limitations set forth in the facility license. He shall be responsible for appointing personnel to all positions reporting to him as described in Section 6.1 of the Technical Specifications. He shall seek the advice and approval of the Radiological Safety Board and/or the Reactor Safety Board in all matters concerning unresolved safety questions, new experi-ments and new procedures, and f acility modifications which might affect safety. He shall be an ex of ficio member of the Reactor Safety Board, 6.1.4 Reactor Supervisor The Reactor Supervisor shall be a licensed SRO and shall be responsible for the preparation, orc =ul2ation, and enforcement of administrative controls including all rules, regulations, instructions, and operating procedures to ensure that the reactor facility is operated in a safe, competent, and authorized manner at all times. He shall direct the activities of operators and technicians in the daily operation and maintenance of the reactor; schedule reactor operations and maintenance; be responsible for the preparation, authenti-cation, and storage of all prescribed logs and operating rewords; authorize all experiments, procedures, and changes thereto which have received the approval of the Reacter Safety Board and/or the Radiological Safety Com-mittee and the Head of the Depart =ent of Nuclear Engineering; and be re-sponsible for the preparation of experimental procedures involving use of the reactor.

6.1.5 Reactor Operators Reactor Operators shall be responsible for the manipulation of the reactor controls, monitoring of instrweentation, operation c ' reactor related equipment, and maintenance of complete and current records during operation of the f acility. Reactor Operators who are exempt frem holding an NRC license per 10 CFR 55 paragraph 55.9 shall only operate the reactor under the direct and i==ediate supervision of a licensed Reactor Operator.

17

6.1.6 Reactor Safety Board The Reactor Safety Board shall be responsible for, but not limited to, reviewing and approving safety standards associated with the use of the reactor f acility; reviewing and approving all proposed experiments and procedures and changes thereto; reviewing and approving all modifica-tions to the reactor f acility which might affect its safe operation; de-termining whether proposed experiments, procedures, or modifications involve unreviewed safety questions, as defined in 10 CFR 50 paragraph 50.59 (c), and are in accordance with these Technical Specifications; conducting periodic audits of procedures, reactor operations and main-tenance, equipment performance, and records; review all reportable occurrences and violations of these Technical Specifications, evaluating the causes of such events and the corrective action taken and recom=ending measures to prevent recurrence; reporting all their findings and recom-mendations concerning the reactor facility to the Head of the Depart =ent of Nuclear Engineering.

6.1.7 Radiological Safety Board The Radiological Safety Board shall advise the University administration and the Radiological Safety Officer en all matters concerning radiological safety at university facilities.

6.1.8 Radiological Safetv Officer The Radiological Safety Officer shall review and approve all procedures and experiments involving radiological safety. He shall enforce all federal, state, and university rules, regulations, and procedures relating to radiological safety. He shall perfor= routine radiation surveys of the reactor facility and report his findings to the Head of the Department of Nuclear Engineering. He shall provide personnel dosi=etry and keep records of personnel radiation exposure. He shall advise the Head of the Department of Nuclear Engineering on all matters concerning radiological safety at the reactor facility. The Radiological Safety Officer shall be an ex officio member of the Reactor Safety Board.

6.1.9 Ooerating Staff a.

The minimum operating staf f during any time in which the reactor is not shutdown shall consist of:

1.

One licensed Reacter Operator in the reactor control room.

2.

One other person in the reactor roca or reactor centrol room certified by the Reactor Supervisor as qualified to activate manual serms and initiate emergency procedures.

3.

One licensed Senior Reactor Operator readily available on call.

This requirement can be satisfied by having a licensed Senior Reactor Operator perform the duties stated in paragraph 1 or 2 above or by designating a licensed Senior Reactor Operator who can be readily contacted by telephone and who can arrive at the reactor facility within 30 =inutes.

18

b.

A licensed Senior Reactor Operator shall supervise all reactor maintenance er modification which could affect the reactivity of the reactor.

6.2 Staff Qualifications The Head of the Department of Nuclear Engineering, the Reactor Supervisor, licensed Reactor Operators, and technicians performing reactor maintenance shall meet the minimum qualifications set forth in ANS 15.4, " Standards for Selection and Training of Personnel for Research Reactors". Reactor Safety Board members shall have a minimum of five (5) years experience in their profession or a baccalaureate degree and two (2) years of professional expe rience. Reactor Safety Board members will generally be University faculty = embers with considerable experience in their area of expertise.

The Radiological Safety Officer shall have a baccalaureate degree in bio-logical or physical science and have at least two (2) years experience in health physics.

6.3 Training The Head of the Department of Nuclear Engineering shall be responsible for directing training as set forth in ANS 15.4, " Standards for Selection and Training of Personnel for Research Reactors". All licensed reactor operators shall participate in requalification training as set forth in 10 CFR 55.

6.4 Reactor Safety Board 6.4.1 Meetings and Quorum The Reactor Safety Board shall meet as often as deemed necessary by the Reactor Safety Board Chair =an but shall meet at least once each calendar year. A quorum for the conduct of official business shall be the chairman, or his designated alternate, and two (2) other regular members. At no time shall the operating organization comprise a voting majority of the members at any Reactor Safety Board meeting.

6.4.2 Reviews The Reactor Safety Board shall review:

a.

Safety evaluations for changes to procedures, equipment or systems, and tests or experiments, conducted without Nuclear Regulatory Cocnis-sien approval under the provision of 10 CFR 50 paragraph 50.59 to verify that such actions do not constitute an unreviewed safety question.

b.

Proposed changes to procedures, equipment or systems that change the original intent or use, and are non-conserecc ive, or those that involve an unreviewed safety questien as defined in 10 CFR 50 paragraph 50.59.

19

c.

Proposed testa or experiments which are significantly different from previously approved tests or experiments, or those that involve an unreviewed safety question as defined in 10 CFR 50 Section 50.59.

d.

Proposed changes in Technical Specifications or licenses.

e.

Violations of applicable statutes, codes, regulations, orders, Techni-cal Specifications, license requirements, or of internal procedures

.or instructions having nuclear safety significance, f.

Significant operating abnormalities or deviations from normal and expected performance of f acility equipment that affect nuclear safety.

g.

Reportable occurrences.

h.

Audit reports.

6.4.3 Audits Audits of f acility activides shall be perfor=ed at least quarterly under the cognizance of the Reactor Safety Board but in no case by the personnel responsible for the item audited. These audits shall examine the operat-ing records and encompass but shall not be limited to the following:

a.

The conformance of the facility operation to the Technical Specifica-tions and applicable license conditions, at least annually, b.

The Facility Emergency Plan and implementing procedures, at least every two years.

c.

The Facility Security Plan and imple=enting procedures, at least every two years.

6.4.4 Authority Th, Reactor Safety Board shall report to the President and shall advise the Head of the Department of Nuclear Engineering on those areas of responsibility outlined in section 6.1.6 of these Technical Specifications.

6.4.5 Minutes of the Reactor Safety Boarc The Chairman of the Reactor Safety Board shall direct the preparation, naintenance, and distribution of minutes of its activities. These minutes shall include a su= mary of all meetings, actions taken, audits, and re.

views.

20

6.5 Approvala The procedure for obtaining approval for any change, modification, or procedure which requiret approval of the Reactor Safety Board shall be as follows:

The Reactor Supervisor shall prepare the proposal for review and a.

approval by the Head of the Department of Nuclear Engineering.

b.

The Head of the Department of Nuclear Engineering shall submit the proposal to the Chairman of the Reactor Safety Board.

c.

The Chairman of the Reactor Safety Board shall submit the proposal to the Reactor Safety Board members for review and comment.

d.

The Reactor Safety Board can approve the proposal by majority vote.

6.6 Pr ocedure s There shall be written procedures that cover the following activities:

a.

Startup, operation, and shutdown of the reactor.

b.

Fuel movement and changes to the core and experiments that could affect reactivity.

c.

Conduct of irradiations and experi=ents that could affect the operation or safety of the reactor, d.

Preventive or corrective =aintenance which could af fect the safety of the reactor, e.

Surveillance, testing, and calibration of instruments, components, and systems as specified in section 4.0 of these Technical Specifica-tions.

f.

Implementation of the Security Plan and Emergency Plan.

The above listed procedures shall be appros ed by the Head of the Depart-ment of Nuclear Engineering and the Reactor Safety Board. Te=porary procedures which do not change the intent of previously approved procedures and which do not involve any unreviewed safety question may be employed on approval by the Reactor Supervisor.

6.7 Exteriments Prior to initiating any new reactor experiment an expeticental procedure a.

shall be prepared by the Reactor Supervisor and reviewed and approved by the Head of the Department of Nuclear Engineering and the Reactor Safety Board.

b.

Approved experiments shall only be performed under the cognizance of the Head of the Department of Nuclear Engineering and the Reactor Supervisor.

21 m

6.8 Safety Limit Violation The following actions shall be taken in the event a Safety Limit is violated :

The reactor will be shutdown i= mediately and reactor operation will a.

not be resumed without authorization by the Nuclear Regulatory Commission (NRC).

b.

The Safety Limit violation shall be reported to the appropriate NRC Regional Office of Inspection and Enforce =ent, the Director of the NRC, and the Reactor Safety Board not later than the next work day, A Safety Limit Violation Report shall be prepared for review by the c.

Reactor Safety Board. This report shall describe the applicable circumstances preceding the violation, the effects of the violation upon f acility components, systems or structures, and corrective action to prevent recurrence.

d.

The Safety Limit Violation Report shall be submitted to the NRC, and Reactor Safety Board within 14 days of the violation.

6.9 Reporting Recuire=ents In addition to the applicable reporting requirements of Title 10, Code

'of! Federal Regulations, the follewing reports shall be submitted to the Director of the appropriate TRC Regional Office.

6.9.1 Annual Oeerating Rerort Routine annual operating reports shall be submitted no later than ninety (90) days following the end of the operating year.

The annual operating reports made by licensees shall provide a comprehensive summary of the operating erperience having safety significance that was gained during the year, even though some repetition of previously reported information may be involved.

References in the annual operating report to previously submitted reports shall be clear.

Each annual operating report shall include:

1.

A brief narrative summary of (a) Changes in facility design, performance characteristics, and operating procedures related to reactor safety that occurred during the reporting period.

(b) Results of major surveillance tests and inspections.

2.

A tabulation shcuing the hours the reactor was operated and the energy produced by the reactor in watt-hours.

3.

List of the unscheduled shutdowns, including the reasons therefore and corrective action taken, if any.

22

4 Discussion of the major safety related corrective =aintenance pqrformed during the period, including the ef fects, if any, on the safe operation of the reactor, and the reasons for the corrective maintenance required.

5.

A brief description of:

(a) Each change to the facility to the extent that it changes a description of the facility in the application for license and amendments thereto.

(b) Changes to the procedures as described in Facility Technical Specifications.

(c) Any new or untried expericents or tests perfor=ed during the reporting period.

6.

A su==ary of the safety evaluation made for each change, test, or experiment not submitted for NRC approval pursuant to 10 CFR 50, Section 50.59 which clearly shows the reason leading to the conclusion that no unreviewed safety question existed and that no technical specification change was re-quired.

7.

A su= mary of the nature and amount of radioactive effluents released or discharged to the environs beyond the effective control of the licensee as deter =ined at or prior to the point of such release er discharge.

(a)

Licuid Waste (su==arized for each release)

(1) Total estimated quantity of radioactivity released (in curies) and Total volume (in liters) of effluent water (including diluent) released.

(b) Solid Waste (summarized for each release)

(1) Total amount of solid waste packaged (in cubic meters)

(2) Total activity in solid waste (in curies)

(3) The dates of shipments and disposition (if shipped off site).

8.

A description of the results of any environmental radiological surveys perfor=ed cutside the f acility.

9.

Radiation Exposure - A su==ary of radiation exposures greater than 100 cre= (50 =re= for persons under 13 years of age) received during the reporting period by facility per sonnel or visitors.

23

6.9.2 Reoortable Occurrences Reportable occurrences, including causes probable consequences, corrective actions and esasures to prevent recurrence, shall be reported to the NRC.

Supplemental reports may be required to fully describe final resolution of the occurrence.

In case of corrected or supplemental reports, an amended licensee event report shall be co=pleted and reference shall be

=ade to the original report date, a.

Promet Notification With Written Followuo.

The types of events listed below shall be reported as expeditiously as possible by telephone and confirmed by telegraph, =ailgram, or facsimile transmission to the Director of the appropriate NRC Regional Office, or his designated representative no later than the first work day following the event, with a written follevup report within two weeks.

Infor=ation provided shall contain narrative material to provide complete explanation of the circumstances surrounding the event.

1.

Failure of the reactor protection syates or other systems subject to limiting safety system settings to initiate the required protective function by the time a monitored parameter reached the setpoint specified as the limiting safety system setting in the technical specifications or failure to com-plete the required protective function.

2.

Operation of the reactor or affected systems when any parameter or operation subject to a li=iting condition is less conserva-tive than the li=iting condition for operation establishad in the technical specifications without taking permitted re=edici action.

3.

Abnormal degradation discovered in a fission product barrier.

4.

Reactivity balance anomalies involving:

(a) Disagreement between expected and actual critical rod positions of approximately 0.3".a k/k.

(b) Exceeding excess reactivity limit.

(c) Shutdevn margin less conservative than specified in technical specifications.

(d) If sub-critical, an unplanned reactivity insertion of more than approxt=ately 0.57. A k/k or any unplanned criticality.

5.

Failure or malfunction of one (or = ore) component (s) which prevents or could prevent, by itself, the fulfill =ent of the functional requirements of system (s) used to cope with acci-dents analyzed in the Safety Analysis Report.

24

,-a.

~-.,

n...

6.

Personnel err:c or procedural inadequacy which prevents, or could prevent, by itself, the fulfillment of the functional require =ents of systems required to cope with accidents analyzed in Safety Analysis Report.

7.

Unscheduled conditions arising from natural or man-made events that, as a direct result of the event require reactor shutdown, operation of safety syste=s, or other protective measures re-qui ed by Technical Specifications.

8.

Errors ciscovered in the transient or accident analyses or in the =ethods used for such analyses as described in the Safety Analysis Report or in the bases for the Technical Specifica-tions that have or could have permitted reactor operation in a =anner less conservative than assumed in the analyses.

9.

Performance of structures, systems, or components that requires remedial action or corrective measures to prevent operation in a manner lesc conservative than assumed in the accident analysis in the Safety Analysis Report or technical specifications bases; or discovery during plant life of conditions not specifically considered in the Safety Analysis Report or Technical Specifications that require remedial action or corrective =easures to prevent the existence or development of an unsafe condition.

6.9.3 Soecial Reoorts Special reports which may be required by the Nuclear Regulatory Ccemission shall be submitted to the Director of the appropriate NRC Regional Office within the time period specified for each report.

6.10 Record Retention 6.10.1 Records to be Retained for a Period of at Least Five Years :

Operating logs or data which shall identify:

a.

1.

Completion of pre-startup checkout, startup, power changes, and shutdown of the reactor.

2.

Installation or removal of fuel elements, control rods or experi-ments that could affect core reactivity.

3.

Insta11s tion or removal of ju=pers, special tags or.sticas, or other temporary changes to reactor safety circuit.y.

25

-m e

--w

4.

Rod worth measurements and other reactivity measurements.

b.

Principal maintenance operations.

c.

Reportable occurrences.

d.

Surveillance activities required by technical specifications.

e.

Facility radiation and conta=ination surveys.

f.

Experiments performed with the reactor.

This requirement may be s:tisfied by the normal operations log book plus, 1.

Records of radioactive material transferred from the facility as required by license.

2.

Records required by the Re actor Safety Board for the perfor=ance of new or special expert =ents.

g.

Changes to operating procedures.

6.10.2 Records to be Retained for the Life of the Facility:

a.

Records of liquid and solid radioact'.ve effluents released to the environs.

b.

Appropriate of f-site environmental monitoring surveys,

c.

Fuel inventories and fuel transfers.

i. Radiation exposures for all personnel, e.

Updated as-built drswings of the f acility.

f.

Records of transient or operational cycles for those components designed for a limited number of transients or cycles.

g.

Records of training and qualification for members of the facility staff.

h.

Records of reviews perfor=ed for changes made to procedures or equipment or reviews of tests and experiments pursuant to 10 CFR 50.59.

i. Records of meetings of the Reactor Safety Board.

26

_