ML19270D979

From kanterella
Jump to navigation Jump to search

Enclosure 1: CoC No. 9157, Rev. No. 17 (Letter to M. Rose Certificate of Compliance No 9157, Revision No. 17, for the Model No. IR-100 Package)
ML19270D979
Person / Time
Site: 07109157
Issue date: 10/01/2019
From: John Mckirgan
Spent Fuel Licensing Branch
To: Maret Rose
Industrial Nuclear Co
Devaser N
Shared Package
ML19270D978 List:
References
EPID L-2019-RNW-0021
Download: ML19270D979 (3)


Text

NRC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATE NUMBER b. REVISION NUMBER c. DOCKET NUMBER d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9157 17 71-9157 USA/9157/B(U)-96 1 OF 3
2. PREAMBLE
a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
3. THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION
a. ISSUED TO (Name and Address) b. TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Industrial Nuclear Company Industrial Nuclear Company application, Revision 14320 Wicks Blvd. No. 4, San Leandro, CA 94577 dated June 2015, as supplemented.
4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

5.

(a) Packaging (1) Model No.: IR-100 (2) Description The Model No. IR-100 package is approximately 8.87 inches long, 4.5 inches wide, and 8.5 inches high. The radioactive material contents consist of Iridium-192 or Selenium-75 in source assemblies that meet the requirements for special form material. The source assemblies are positioned within a zircalloy or titanium S tube within the IR-100. The S tube is surrounded by a shield assembly made of depleted uranium. The uranium shield assembly is encased in a stainless steel housing. The space between the uranium shield assembly and the stainless steel casing is filled with a rigid polyurethane foam. The maximum weight of the IR-100 exposure device is 53 pounds and the maximum shield weight is 38 pounds.

(3) Drawings The packaging is constructed in accordance with Industrial Nuclear Company Drawing Nos.: IR 100-1A, Rev. 5 and IR 100-1B, Rev. 3.

NRC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATE NUMBER b. REVISION NUMBER c. DOCKET NUMBER d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9157 17 71-9157 USA/9157/B(U)-96 2 OF 3 (b) Contents (1) Type and form of material Iridium-192 or Selenium-75 as sealed sources that meet the requirements of special form radioactive material.

(1) Maximum quantity of material per package 120 (output) curies Output curies are determined in accordance with American National Standard N432-1980, Radiological Safety for the Design and Construction of Apparatus for Gamma Radiography.

6. The source must be secured in the shielded position of the packaging by the shipping plug, source assembly lock, and lock cap. The shipping plug, source assembly lock, and lock cap used must be fabricated of materials capable of resisting a 1475°F fire environment for one-half hour and maintaining their positioning function. The ball stop of the source assembly lock must engage the locking device. The flexible cable of the source assembly and shipping plug must be of sufficient length and diameter to provide positive positioning of the source in the shielded position.
7. The name plate on the exposure device must be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining its legibility.
8. In addition to the requirements of Subpart G of 10 CFR Part 71:

(a) The package must meet the Acceptance Tests and Maintenance Program of Section 8 of the application; and (b) Each package shall be operated and prepared for shipment in accordance with the operating procedures in accordance with Section 7 of the application.

9. The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.
10. Revision No. 16 of this certificate may be used until October 31, 2019.
11. Expiration date: October 31, 2024.

NRC FORM 618 U.S. NUCLEAR REGULATORY COMMISSION (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1. a. CERTIFICATE NUMBER b. REVISION NUMBER c. DOCKET NUMBER d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9157 17 71-9157 USA/9157/B(U)-96 3 OF 3 REFERENCES Industrial Nuclear Company application dated June 2015.

Supplements dated: July 8, August 6, 2015; February 16, 2017; July 15, 2019.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

/RA/

John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Date: October 1, 2019