ML19269D125
| ML19269D125 | |
| Person / Time | |
|---|---|
| Site: | Bailly |
| Issue date: | 02/09/1979 |
| From: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Shorb E NORTHERN INDIANA PUBLIC SERVICE CO. |
| References | |
| NUDOCS 7902270354 | |
| Download: ML19269D125 (1) | |
Text
.. - -..
T Wk c,
4 UNITED STATES f
/
'k NUCLEAR REGULATORY COMMISSION
,)
REGION 111 f
799 ROOSEVELT ROAD gj GLE N E LLYN, IL LINolS 60137 FEBD
,379 Docket No. 50-367 Northern Indiana Public Service Company ATTN:
Mr. Eugene M. Shorb Senior Vice President 5265 Hohman Avenue Hammond, IN 46325 Gentlemen:
This Information Notice is provided as an early notification of a possibly significant matter. It is expected that recipients will review the information for possible applicability to their facili-ties. No specific action or response is requested at this time.
If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.
If you have questions regarding the matter, please contact the Director of the appropriate NRC Regional Of fice.
Sincerely,
_~ b ames G. Ke p cr Director
Enclosures:
1.
IE Information Notice No. 79-03 2.
List of IE Information Notices Issued in 1979 cc w/encls:
Central Files Director, NRR/DPM Director, NRR/ DOR PDR Local PDR NSIC TIC Mr. Dean Hansell, Office of Assistant Attorney General 7902270nN
e U.S. NUCLEAR REGULATORY CO)NISSION OFFICE OF INSPECTION ASD E5FORCEMENT RECION III February 9, 1979 IE Information Notice No. 79-03 LIMITORQUE VALVE GEARED LIMIT SWITCH LUBRICANT Description of Circumstances:
At Co=monwealth Edison reactors excessive failure rates of the Limitorque valve geared limit switches were being experienced.
Investigation revealed that the failure mode was a drying out and hardening of the Beacon 325 lubricant. Once hardening takes place, the brass gears within the limit switch become immobile and destroy themselves when an attempt is made to operate the valve.
The Limitorque Corporation has recommended Mob 11 grease 28 as a replacement grease for switch applications where the te=perature exceeds 140 degrees Fahrenheit. Tests conducted by Mobil and Limitorque Corporation indicate that Mobilgrease 28, in addition to having a superior temperature rating, will satisfy the same environmental conditions and meet the same qualification parameters as Beacon 325.
All licensee and construction permit holders should consider conducting a review to determine if Beacon 325 lubricant is being used in geared limit switches in environments conducive to drying out and subsequent hardening of the lubricant.
If conditions are found.to be conducive to failures, consideration should be given to replacing the-grease with a more suitable grease.
This information is provided as an early notification of a possibly significant matter.
It is expected that recipients vill review the information-for possible. applicability to their-facilities.
No. specific action or response is requested at this time.
If further NRC evalua-tions so-indicate, an IE-Circular or Bulletin will be issued to recom-mend or request specific licensee actions.
If you have questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.