| Site: | 07000036 |
| Issue date: | 12/13/1978 |
| From: | Crow W NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Rankin R MISSOURI, STATE OF |
| References | |
| NUDOCS 7901190190 | |
| Download: ML19269B997 (4) | |
Text
})i)fb A. */
UNITED STATES O 'i.
7 'e NUCLEAR REGULATORY COMMISSION f},h k,,h WASHINGTON, D. C. 20555 s.e lj
- 6 DEC 131978 FCPF:EYS 70-36 Missouri Department of Natural Resources ATTN: 15. R. F. Rankin Director of Staff Missouri Clean Water Commission 2010 Missouri Road
.lefferson City, Missouri 65102
Dear Mr. Rankin:
Enclosed for your record are Tables 1-4 summarizing the potential radiological impact from the normal operation of Combustion Engineering's (CE) Hematite Plant. These tables were presented at the November 30, 1978 public hearing concerning the change in CE's NPDES discharge permit.
If there are any questions please feel free to call.
Sincerely, f
W. T. Crow, Section Leader Uranium Fuel Fabrication Section Fuel Processing & Fabrication Branch Division of Fuel Cycle and Material Safety
Enclosure:
As stated 7901190lN
DEC 131978 RADIOLOGICAL IMPACT The average annual discharge of radiological effluents from the C-E plant operation and the significant pathways that lead to individual dose commitment at the nearest residence are summarized in Table 1.
Table 1 Annual Rate Significant of Discharge Environmental (Ci/yr)
Pathways
- 1. Gaseous 4.09x10-4 Inhalation, Ingestion (atmosphere)
(terrestrial)
- 2. Liquid 0.0?66 Ingestion (water, fish)
(surface water)
- 3. Liquid 0.0019 None (site retention pond)
DEC 13 13I8
. Table 2 Estimated Maximum Annual Dose To A Hypothetical Individual At The Nearest Site Boundary Pathway EPA Standard Organ Dose (millirem /yd Lung Bone
- 1. Inhalation 5.4(a)
- 2. Ingestion
<0.l(b)
(crop-milk-beef-fish)
TOTAL 25 mr/yr 5.4~
<0.1 Table 3 Estimated Maximum Annual Dose To An Individual At The Nearest Residence Pathway EPA Standard Organ Dose (millirems)
Lung Bone
- 1. Inhalation 0.0076(a)
- 2. Ingestion 0.0060(b)
(crop-milk-beef-fish)
TOTAL 25 mr/yr 0.0076 0.0060 3 of air inhaled daily (a) Assumes 20 m (b) Assumes all food consumed is produced at the site; daily intake 1.0 liter of milk, 0.25 kg of vegetables and 0.3 kg of beef.
1 Task Group on Lung Dynamics of Committee II of the International Commission on Radiological Protection, " Deposition and Retention Modes for Internal Dosimetry of the Human Respiratory Tract,"
Health Physics 12:173, 1966.
2 INREM Code - A Methodology for Calculating Dose from Radioactivity Released to the Environment ORNL-4992, March 1976.
DEC 131978 Table 4 Concentration of Uranium In Joachim Creek and the Miscissippi River Concentration Drinking Water Standard
% of Standard (ppm)
- 1. Joachim 7.3x10-Sppm 5 ppm 0.0015%
Creek
'(0.14 pC/1)
- 2. Mississippi 5.5x10-eppm 5 ppm 0.0000011%
River (0.00011 pC/1)