ML19263G139

From kanterella
Jump to navigation Jump to search
Discusses IE Insp of License 45-18378-01MD on 791206 & Forwards Notice of Violation
ML19263G139
Person / Time
Issue date: 01/18/1980
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Potter M
PHARMATOPES, INC.
Shared Package
ML19263G137 List:
References
FOIA-80-341 NUDOCS 8003190529
Download: ML19263G139 (2)


Text

nasog#

e UNITED STATES E'

o

~

NUCLEAR REGULATORY COMMISSION n$

REGION 11 e'['

0, 101 MARIETTA ST., N.W., sulTE 3100 AT LANTA, G EoRGI A 30303 In Reply Refer To:

JAN 1 B 1360 RII:RLW 45-18378-01MD Pharmatopes, Inc.

Attn: Murray F. Potter, R.PH., M.S.

Vice President 83 South Witchduck Road Virginia Beach, Virginia 23462 Gentlemen:

This refers to the inspection conducted by R. L. Woodruff of this office on December 6, 1979, of activities authorized by NRC License No. 45-18378-01MD for the Virginia Beach facility, and to the discussion of our findings held with you at the conclusion of the inspection.

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Commission's rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.

During the inspection, it was found that certain activities under your license appear to be in noncompliance with NRC requirements. These items and references to pertinent requirements are listed in the Notice of Violation enclosed herewith as Appendix A.

This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regula-tions. Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement or explanation in reply including:

(1) corrective steps which have been taken by you and the results achieved; (2) corrective steps which will be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter will be placed in the NRC's Public Doctiment Room.

If this letter contains any information that you believe to be proprietary, it is necessary that you make a written application within 20 days to this office to withhold such information from public disclosure.

Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document. If we do not hear from you in this regard within the specified period, the letter will be placed in the Public Document Room.

sooaigo

jgt; ) 8 GB0

- Pharmatopes, Inc.

Should you have any questions concerning this letter, we will be glad to discuss them with you.

Sincerely, 5

s

/'

e J. P ilip Stohr, Chief Fuel Facility and Materials Safety Branch

Enclosure:

Appendix A, Notice of Violation